Decay of Electric Charge on Corona Charged Polyethylene


Zhang, L, Xu, Z and Chen, G (2007) Decay of Electric Charge on Corona Charged Polyethylene. At 12th International Conference on Electrostatics, Oxford, UK,

Download

[img] PDF
Download (140Kb)

Description/Abstract

In this paper, the surface potential decay of corona-charged low density polyethylene (LDPE) films has been investigated. It has been found that for the same sample thickness the faster decay occurs in the sample with a higher charging voltage. For the same charging voltage, the surface potential in the thinner sample shows rapid decay. Our new evidence from both the surface potential measurement on multilayer samples and space charge measurement suggests the surface potential decay is a bulk limited process. More importantly, space charge measurement indicates double injection has taken place during corona charging process.

Item Type: Conference or Workshop Item (Poster)
Additional Information: Event Dates: 25 March
Divisions: Faculty of Physical and Applied Science > Electronics and Computer Science
Faculty of Physical and Applied Science > Electronics and Computer Science > EEE
Item ID: 264118
Date Deposited: 06 Jun 2007
Last Modified: 02 Mar 2012 11:59
Contributors: Zhang, L (Author)
Xu, Z (Author)
Chen, G (Author)
Date: 2007
Additional Information: Event Dates: 25 March
Status: Published
Further Information:Google Scholar
ISI Citation Count:15
URI: http://eprints.soton.ac.uk/id/eprint/264118

Actions (login required)

View Item View Item