Measurement of Leakage Current at the Oil-Pressboard Interface during Surface Discharge


Zainuddin, H, Lewin, P L and Mitchinson, P M (2012) Measurement of Leakage Current at the Oil-Pressboard Interface during Surface Discharge. In, The Fifth UHVnet Colloquium, University of Leicester, Leicester, UK, 18 - 19 Jan 2012. , 24.

Download

[img] PDF
Download (441Kb)
[img] PDF - Published Version
Download (163Kb)

Description/Abstract

Surface discharge at the oil-pressboard interface is classified as one of the most dangerous fault conditions of large transformers. Surface discharges can be sustained for long periods without surface flashover or breakdown as long as the surface breakdown voltage is not exceeded [1]. Damage at the pressboard surface due to surface discharge is a function of applied voltage and time. If an applied voltage, above the surface partial discharge inception voltage (PDIV) but less than surface flashover voltage persists, the resulting discharges can develop a creeping path due to the drying out of the pressboard by localized heating (forcing oil and water out of the pressboard pores) and the carbonization of the oil and cellulose [1]. The drying of pressboard during the surface discharge process has been observed as the development of white marks on the pressboard surface [1]. A surface discharge experiment using a needle-bar electrode configuration has been developed. A shunt resistor that has been extensively used to measure leakage current for outdoor insulation systems [2] is used in the experiment. The leakage current is also measured using a commercial partial discharge detection system to allow comparison of the leakage current waveform from the oscilloscope against the corresponding phase resolved partial discharge (PRPD) pattern obtained. Figure 1 shows an example of measured leakage current during the occurrence of full-length discharge. It has been found that after long periods of surface discharge, temporary full-length discharges may occur across the pressboard surface bridging the needle tip and the earth without resulting in complete electrical breakdown. The full-length discharges occur when the white marks have reached the earth bar and travel along the same path as the white marks [3]. The occurrence of this full-length discharge leads to small leakage current (mA range) flowing to earth that is unlikely to trip the earth fault protection relays [3]. Although the currents are relatively small, identifying their presence and relating them to forms of PD activity at the pressboard oil interface is important as it may provide a mechanism for earlier detection of creep stress failure.

Item Type: Conference or Workshop Item (Paper)
Additional Information: Event Dates: 18-19 January 2012
Divisions: Faculty of Physical Sciences and Engineering > Electronics and Computer Science > EEE
Faculty of Physical Sciences and Engineering > Electronics and Computer Science
ePrint ID: 273127
Date Deposited: 20 Jan 2012 14:56
Last Modified: 27 Mar 2014 20:18
Further Information:Google Scholar
ISI Citation Count:1
URI: http://eprints.soton.ac.uk/id/eprint/273127

Actions (login required)

View Item View Item

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics