Film cooling effectiveness for subsonic slot injection into a cross flow
Fitt, A.D. and Stefanidis, V. (1998) Film cooling effectiveness for subsonic slot injection into a cross flow. Acta Mechanica, 128, (3-4), 233-242. (doi:10.1007/BF01251893).
Download
Full text not available from this repository.
Description/Abstract
A model is developed that allows the prediction of the film cooling effectiveness produced by slot injection into a uniform cross flow. The model relies on the fact that when the slot pressure exceeds the cross flow pressure by a small amount only so that injection is weak, the resulting small parameter may be exploited to solve the flow problem. The energy equation for the flow may then be solved to determine how much protection cold gas injection gives to the wall downstream of a slot. Although the leading order energy equation must be solved numerically, a simple asymptotic expression may also be derived to allow predictions of heat transfer at large distances from the injection slot.
| Item Type: | Article |
|---|---|
| ISSNs: | 0001-5970 (print) |
| Related URLs: | |
| Subjects: | T Technology > TL Motor vehicles. Aeronautics. Astronautics |
| Divisions: | University Structure - Pre August 2011 > School of Mathematics > Applied Mathematics |
| Item ID: | 29117 |
| Date Deposited: | 22 Dec 2006 |
| Last Modified: | 02 Mar 2012 13:49 |
| Contributors: | Fitt, A.D. (Author) Stefanidis, V. (Author) |
| Date: | 1998 |
| Status: | Published |
| URI: | http://eprints.soton.ac.uk/id/eprint/29117 |
Actions (login required)
![]() |
View Item |