Visible light detection in microflow cytometry - advancing miniaturisation and detection methods
Visible light detection in microflow cytometry - advancing miniaturisation and detection methods
The advent of optical flow cytometry in the 1980s created a growing demand for flow cytometers in biomedical research and inspired scientists to build or modify commercial instruments.
Oceanographers use flow cytometers to perform phytoplankton analysis in remote locations on board ships. Our current knowledge of the role of algae and phytoplankton and their impact on global climate is limited by the frequency with which it can be analysed. Cytometric analysis of phytoplankton life cycles in their natural environment has the potential to revolutionise our understanding, but requires the use of miniaturised devices to operate at remote locations. To date, many research groups have developed unique flow cytometer systems to enable in-situ phytoplankton analysis. The development and miniaturisation process continues, and there is still a need to improve detection limits, modularity, and maintenance requirements. Furthermore, recent advancements in image processing and the availability of high resolution and high sensitivity cameras enable combining flow cytometry with microscopy. Image flow cytometry offers better morphological information, and unlike traditional cytometry, has the potential to screen multiple particles at a time, increasing the throughput. High throughput is also highly desired in an early detection and monitoring of hematological diseases such as leukemia, and other cancers.
The aim of this thesis is to contribute to the development process of the traditional micro flow cytometry and imaging cytometry. Two kinds of devices were described and investigated in this thesis. The first device was a micro-flow cytometer chip based on optical fibre coupled architecture with an integrated micro lens that was fabricated to demonstrate an integrated fluorescence collection method by using a miniature cylindrical lens with a graded refractive index profile. The fluorescence collection efficiency was found comparable to a standard microscope objective. The use of the micro lens represents a significant progress in miniaturisation and assembly without sacrificing of performance. Practical use of the device was demonstrated by optical differentiation of phytoplankton cultures by detection of fluorescence, forward, and side scattered light. In addition, the device was tested with plain polystyrene, and fluorescent particles. The results were compared against two commercial instruments. The second device presented in this thesis is an imaging flow cytometer that uses acoustic levitation to assemble particles into a sheet structure. A high resolution, low noise CMOS camera is then used to capture images of thousands of cells with each frame. While ultrasonic focussing has previously been demonstrated for 1D cytometry systems, extending the technology to a planar, much higher throughput format and integrating imaging is non-trivial, and represents a significant jump forward in capability, leading to diagnostic possibilities not achievable with current systems. A galvo mirror was used to track the images of the moving cells permitting exposure times of 10ms at frame rates of 50Hz with near-single-pixel motion blur. At 80 Hz, a throughput of over 200k particles per second was achieved with particle velocities reaching 104 mm/s. The factors affecting motion blur and throughput were studied, and demonstrated the system with fluorescent beads, leukocytes, chondrocyte cell lines, and algae.
University of Southampton
Zmijan, Robert
3ef86bd8-33b5-4fac-98d2-1133fcf7a72f
March 2016
Zmijan, Robert
3ef86bd8-33b5-4fac-98d2-1133fcf7a72f
Morgan, Hywel
de00d59f-a5a2-48c4-a99a-1d5dd7854174
Zmijan, Robert
(2016)
Visible light detection in microflow cytometry - advancing miniaturisation and detection methods.
University of Southampton, Faculty of Physical Sciences and Engineering, Doctoral Thesis, 181pp.
Record type:
Thesis
(Doctoral)
Abstract
The advent of optical flow cytometry in the 1980s created a growing demand for flow cytometers in biomedical research and inspired scientists to build or modify commercial instruments.
Oceanographers use flow cytometers to perform phytoplankton analysis in remote locations on board ships. Our current knowledge of the role of algae and phytoplankton and their impact on global climate is limited by the frequency with which it can be analysed. Cytometric analysis of phytoplankton life cycles in their natural environment has the potential to revolutionise our understanding, but requires the use of miniaturised devices to operate at remote locations. To date, many research groups have developed unique flow cytometer systems to enable in-situ phytoplankton analysis. The development and miniaturisation process continues, and there is still a need to improve detection limits, modularity, and maintenance requirements. Furthermore, recent advancements in image processing and the availability of high resolution and high sensitivity cameras enable combining flow cytometry with microscopy. Image flow cytometry offers better morphological information, and unlike traditional cytometry, has the potential to screen multiple particles at a time, increasing the throughput. High throughput is also highly desired in an early detection and monitoring of hematological diseases such as leukemia, and other cancers.
The aim of this thesis is to contribute to the development process of the traditional micro flow cytometry and imaging cytometry. Two kinds of devices were described and investigated in this thesis. The first device was a micro-flow cytometer chip based on optical fibre coupled architecture with an integrated micro lens that was fabricated to demonstrate an integrated fluorescence collection method by using a miniature cylindrical lens with a graded refractive index profile. The fluorescence collection efficiency was found comparable to a standard microscope objective. The use of the micro lens represents a significant progress in miniaturisation and assembly without sacrificing of performance. Practical use of the device was demonstrated by optical differentiation of phytoplankton cultures by detection of fluorescence, forward, and side scattered light. In addition, the device was tested with plain polystyrene, and fluorescent particles. The results were compared against two commercial instruments. The second device presented in this thesis is an imaging flow cytometer that uses acoustic levitation to assemble particles into a sheet structure. A high resolution, low noise CMOS camera is then used to capture images of thousands of cells with each frame. While ultrasonic focussing has previously been demonstrated for 1D cytometry systems, extending the technology to a planar, much higher throughput format and integrating imaging is non-trivial, and represents a significant jump forward in capability, leading to diagnostic possibilities not achievable with current systems. A galvo mirror was used to track the images of the moving cells permitting exposure times of 10ms at frame rates of 50Hz with near-single-pixel motion blur. At 80 Hz, a throughput of over 200k particles per second was achieved with particle velocities reaching 104 mm/s. The factors affecting motion blur and throughput were studied, and demonstrated the system with fluorescent beads, leukocytes, chondrocyte cell lines, and algae.
More information
Published date: March 2016
Organisations:
University of Southampton, Nanoelectronics and Nanotechnology
Identifiers
Local EPrints ID: 394400
URI: http://eprints.soton.ac.uk/id/eprint/394400
PURE UUID: e7137acc-5af9-4562-93af-5a6bc9ec188d
Catalogue record
Date deposited: 06 Jul 2016 11:05
Last modified: 15 Mar 2024 03:18
Export record
Contributors
Author:
Robert Zmijan
Thesis advisor:
Hywel Morgan
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics