Reliability Case Notes No. 5: Report on water leak in Autosub6000 charge blanking plug. Burton blank No 82530-12-5502-3212-0000 NR
Stevenson, P. (2009) Reliability Case Notes No. 5: Report on water leak in Autosub6000 charge blanking plug. Burton blank No 82530-12-5502-3212-0000 NR. Southampton, UK, National Oceanography Centre Southampton, 7pp. (National Oceanography Centre Southampton Research and Consultancy Report, (66) ).
Download
|
PDF
Restricted to Registered users only Download (312Kb) | Request a copy |
Description/Abstract
The blanking plug, Burton Part No 82530-12-5502-3212-0000 NR, which blocks off the charge lead on Autoub6000 leaked water during two missions on the JC027 cruise. An investigation showed fibres had become trapped inside the connector which would have caused a leak. Measurement of the plug and connector shows the secondary seal around the pins and sockets to be marginal. Care to avoid debris being trapped and better tools to aid tightening the connector will avoid a repeat of the problem.
| Item Type: | Monograph (Technical Report) |
|---|---|
| Additional Information: | Deposited at the request of the author |
| Subjects: | V Naval Science > VM Naval architecture. Shipbuilding. Marine engineering |
| Divisions: | University Structure - Pre August 2011 > National Oceanography Centre (NERC) |
| Item ID: | 71780 |
| Date Deposited: | 22 Dec 2009 |
| Last Modified: | 03 Mar 2012 06:11 |
| Contributors: | Stevenson, P. (Author) |
| Date: | 2009 |
| Additional Information: | Deposited at the request of the author |
| Status: | Published |
| Publisher: | National Oceanography Centre Southampton |
| URI: | http://eprints.soton.ac.uk/id/eprint/71780 |
Actions (login required)
![]() |
View Item |