Building refurbishment is a key issue to improve energy performance and comfort levels for the building users. However, changes to an existing building envelope or a narrow energy focussed refurbishment to modern standards can result in a compromised working environment. This paper describes the extension of an administration building at Southampton University through the addition of a new building linked at several levels to the old building through an atrium. Measured aspects of visual and thermal comfort are related to occupant perception and behaviour. The study shows that changes to the building envelope can have a disproportionate impact on the perceived comfort of the working environment in an existing office space. Measures to address this problem are discussed, for example more appropriate relocation of staff and management of expectations concerning the change in performance of the building.
Jentsch, M.F.
c3be9da0-453d-4e1d-8620-0cf5873ce501
James, P.A.B.
da0be14a-aa63-46a7-8646-a37f9a02a71b
Bahaj, A.S.
a64074cc-2b6e-43df-adac-a8437e7f1b37
Jentsch, M.F.
c3be9da0-453d-4e1d-8620-0cf5873ce501
James, P.A.B.
da0be14a-aa63-46a7-8646-a37f9a02a71b
Bahaj, A.S.
a64074cc-2b6e-43df-adac-a8437e7f1b37

Jentsch, M.F., James, P.A.B. and Bahaj, A.S. (2006) A climatic envelope extension of an office building - perception and reality of the change in environmental conditions. Proceedings CIBSE National Conference, London, UK. 21 - 22 Mar 2006.

Record type: Conference or Workshop Item (Paper)

Abstract

Building refurbishment is a key issue to improve energy performance and comfort levels for the building users. However, changes to an existing building envelope or a narrow energy focussed refurbishment to modern standards can result in a compromised working environment. This paper describes the extension of an administration building at Southampton University through the addition of a new building linked at several levels to the old building through an atrium. Measured aspects of visual and thermal comfort are related to occupant perception and behaviour. The study shows that changes to the building envelope can have a disproportionate impact on the perceived comfort of the working environment in an existing office space. Measures to address this problem are discussed, for example more appropriate relocation of staff and management of expectations concerning the change in performance of the building.

This record has no associated files available for download.

More information

Published date: 2006
Venue - Dates: Proceedings CIBSE National Conference, London, UK, 2006-03-21 - 2006-03-22

Identifiers

Local EPrints ID: 53530
URI: http://eprints.soton.ac.uk/id/eprint/53530
PURE UUID: e1e717aa-49ac-4c87-8a89-4ca685cc09f5
ORCID for P.A.B. James: ORCID iD orcid.org/0000-0002-2694-7054
ORCID for A.S. Bahaj: ORCID iD orcid.org/0000-0002-0043-6045

Catalogue record

Date deposited: 29 Jul 2008
Last modified: 12 Dec 2021 02:48

Export record

Contributors

Author: M.F. Jentsch
Author: P.A.B. James ORCID iD
Author: A.S. Bahaj ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×