The University of Southampton
University of Southampton Institutional Repository

Intraoperative optical measurement of function in the human brain

Intraoperative optical measurement of function in the human brain
Intraoperative optical measurement of function in the human brain
Intraoperative determination of function is important to surgeons to maximize the outcome of surgery, for example the extent of tumor resection, and minimize post-surgical deficit. This paper will outline the continued work developing a camera system sensitive to tissue blood oxygen level. Tissue blood oxygen level although not a direct measure of activation is exploited by functional MRI (fMRI) to infer eloquence and has a high correlation with other techniques. Current intraoperative techniques such as electro-cortical stimulation use an alternating electrical current to inhibit brain function in the area it is applied. The patient is then required to perform a task or report sensation; this takes time and provides a rather limited resolution (typically about 5mm). Preoperative techniques such as fMRI and PET suffer from poor spatial resolution (typically 4mm) and more importantly registration issues as brain tissue can move by as much as 15mm during surgery. The camera system images the entire surgical field at a high resolution and may provide the surgeon with real-time information. Initially data was collected using a free standing camera optimized for high signal to noise. These results showed a high correlation with electro-cortical stimulation. The latest development of this camera has seen it attached to a Zeiss surgical microscope to provide an improved perspective on the surgical field. Results from this system are expected shortly and are expected to establish a strong correlation with current techniques and to provide real-time information.
Hoy, P.R.
be1c629f-ea0c-400a-ad39-317d4b14ad31
Rutt, H.N.
e09fa327-0c01-467a-9898-4e7f0cd715fc
Gray, W.P.
e0ba5a65-bd74-4a4f-b640-5abf64fbb377
Bulters, D.O.
d6f9644a-a32f-45d8-b5ed-be54486ec21d
Hoy, P.R.
be1c629f-ea0c-400a-ad39-317d4b14ad31
Rutt, H.N.
e09fa327-0c01-467a-9898-4e7f0cd715fc
Gray, W.P.
e0ba5a65-bd74-4a4f-b640-5abf64fbb377
Bulters, D.O.
d6f9644a-a32f-45d8-b5ed-be54486ec21d

Hoy, P.R., Rutt, H.N., Gray, W.P. and Bulters, D.O. (2009) Intraoperative optical measurement of function in the human brain. SPIE Photonics West 2009 BiOS Biomedical Optics Symposium: Optical Techniques in Neurosurgery, Brain Imaging and Neurobiology Conference, San José. 24 - 29 Jan 2009.

Record type: Conference or Workshop Item (Paper)

Abstract

Intraoperative determination of function is important to surgeons to maximize the outcome of surgery, for example the extent of tumor resection, and minimize post-surgical deficit. This paper will outline the continued work developing a camera system sensitive to tissue blood oxygen level. Tissue blood oxygen level although not a direct measure of activation is exploited by functional MRI (fMRI) to infer eloquence and has a high correlation with other techniques. Current intraoperative techniques such as electro-cortical stimulation use an alternating electrical current to inhibit brain function in the area it is applied. The patient is then required to perform a task or report sensation; this takes time and provides a rather limited resolution (typically about 5mm). Preoperative techniques such as fMRI and PET suffer from poor spatial resolution (typically 4mm) and more importantly registration issues as brain tissue can move by as much as 15mm during surgery. The camera system images the entire surgical field at a high resolution and may provide the surgeon with real-time information. Initially data was collected using a free standing camera optimized for high signal to noise. These results showed a high correlation with electro-cortical stimulation. The latest development of this camera has seen it attached to a Zeiss surgical microscope to provide an improved perspective on the surgical field. Results from this system are expected shortly and are expected to establish a strong correlation with current techniques and to provide real-time information.

This record has no associated files available for download.

More information

e-pub ahead of print date: 2009
Published date: January 2009
Venue - Dates: SPIE Photonics West 2009 BiOS Biomedical Optics Symposium: Optical Techniques in Neurosurgery, Brain Imaging and Neurobiology Conference, San José, 2009-01-24 - 2009-01-29

Identifiers

Local EPrints ID: 65797
URI: http://eprints.soton.ac.uk/id/eprint/65797
PURE UUID: 7aaec0dc-9fb0-4d77-9123-3effb200fffa
ORCID for D.O. Bulters: ORCID iD orcid.org/0000-0001-9884-9050

Catalogue record

Date deposited: 31 Mar 2009
Last modified: 08 Jan 2022 03:35

Export record

Contributors

Author: P.R. Hoy
Author: H.N. Rutt
Author: W.P. Gray
Author: D.O. Bulters ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×