Browse by Divisions pre August 2011

Up a level
Export as [feed] Atom [feed] RSS 1.0 [feed] RSS 2.0
[tool] Add To Shelf...
Number of items: 42.

Bolland, B.J.R.F, Tilley, S., New, A.M.R., Dunlop, D.G. and Oreffo, R.O.C. (2007) Adult mesenchymal stem cells and impaction grafting – a new clinical paradigm shift. Expert Review of Medical Devices, 4, (3), 393-404. (doi: 10.1586/17434440.4.3.393).

Bolland, B.J.R.F, New, A.M.R., Madabhushi, S.P.G., Oreffo, R.O.C. and Dunlop, D.G. (2007) Vibration-assisted bone-graft compaction in impaction bone grafting of the femur. Journal of Bone and Joint Surgery: British Volume, 89-B, (5), 686-692. (doi:10.1302/0301-620X.89B5.18695).

Bolland, B.J.R.F., New, A.M.R., Oreffo, R.O.C. and Dunlop, D.G. (2007) Augmentation of biological and mechanical properties of allograft in impaction bone grafting. In, Engineers and Surgeons: Joined at the Hip, London, UK, 19 - 21 Apr 2007. UK,

Bolland, B.J.R.F., New, A.M.R., Oreffo, R.O.C. and Dunlop, D.G. (2007) Improving both the biological and mechanical properties of allograft in impaction bone grafting: a role for human bone marrow stromal cells. In, 8th European Fedaration of National Associations of Orthopaedics and Traumatology Congress, Florence, Italy, 11 - 15 May 2007. Italy,

Bolland, B.J.R.F., New, A.M.R., Oreffo, R.O.C. and Dunlop, D.G. (2007) The role of vibration in impaction bone grafting. In, Engineers and Surgeons: Joined at the Hip, London, UK, 19 - 21 Apr 2007. UK,

Bolland, B.J.R.F., New, A.M.R., Oreffo, R.O.C. and Dunlop, D.G. (2007) The role of vibration in impaction bone grafting: reducing the risk of fracture and improving bone graft strength. In, Meeting of the Orthopaedics Section of the Royal Society of Medicine, 01 May 2007. UK,

Bolland, B.J.R.F., New, A.M.R., Oreffo, R.O.C. and Dunlop, D.G. (2007) The use of vibration-assisted graft compaction in impaction bone grafting. Reducing the risk of fracture whilst improving bone graft strength. At 8th European Federation of National Associations of Orthopaedics and Traumatology Congress, Florence, Italy, 11 - 15 May 2007. Italy,

Bolland, B.J.R.F., New, A.M.R., Oreffo, R.O.C. and Dunlop, D.G. (2007) The use of vibration-assisted graft compaction in impaction bone grafting: improvement in bone graft strength without increased risk of fracture. At 1st Joint Meeting of the Bone Research Society and the British Orthopaedic Research Society, Southampton, UK, 05 - 06 Jul 2006. UK,

Bolland, B.J.R.F., New, A.M.R., Oreffo, R.O.C. and Dunlop, D.G. (2007) Vibration assisted femoral impaction bone grafting: reducing the risk of fracture whilst improving bone graft strength. In, British Hip Society: Annual Meeting, Leeds, UK, 28 Feb - 02 Mar 2007. UK,

Bolland, B.J.R.F., Partridge, K., New, A.M.R., Dunlop, D.G. and Oreffo, R.O.C. (2007) Augmentation of allograft with human bone marrow stromal cells: validation of cell survival, proliferation, osteogenic phenotype and mechanical strength. In, 1st Joint Meeting of the Bone Research Society and the British Orthopaedic Research Society, Southampton, UK, 05 - 06 Jul 2006. UK,

Briscoe, A., Saffari, N. and New, A.M.R. (2007) An ultrasound technique for monitoring polymerisation of acrylic bone cement. At 53rd Annual Meeting of the Orthopaedic Research Society, San Diego, USA, 11 - 14 Feb 2007. USA,

Checa-Esteban, S. and New, A.M.R. (2007) Simulation of a knee implanted with an interpositional spacer during a gait cycle using explicit finite element analysis. In, 5th World Congress of Biomechanics, Munich, Germany, 19 Jul - 04 Aug 2006. Germany,

Checa-Esteban, S., New, A.M.R. and Taylor, M. (2007) Degeneration propensity of articular cartilage in a knee implanted with an interpositional spacer. In, European Society of Biomechanics Workshop 2007: Finite Element Modelling in Biomechanics & Mechanobiology, Dublin, Ireland, 26 - 28 Aug 2007. Dublin, Ireland,

Checa-Esteban, S., New, A.M.R. and Taylor, M. (2007) Effects of ligament pretension on the biomechanics of the knee: a finite element analysis. In, 52nd Annual Meeting of the Orthopaedic Research Society, Chicago, USA, 19 - 22 Mar 2006. USA, Orthopaedic Research Society.

Dopico-Gonzalez, C., New, A.M.R. and Browne, M. (2007) Probabilistic analysis of an uncemented total hip replacement. In, European Society of Biomechanics Workshop 2007: Finite Element Modelling in Biomechanics and Mechanobiology, Dublin, Ireland, 26 - 28 Aug 2007. Dublin,

Fantner, Georg E., Adams, Jonathan, Turner, Patricia, Thurner, Philipp J., Fisher, Larry W. and Hansma, Paul K. (2007) Nanoscale Ion mediated networks in bone: osteopontin can repeatedly dissipate large amounts of energy. Nano Letters, 7, (8), 2491-2498. (doi:10.1021/nl0712769).

Hopkins, A.R., Checa-Esteban, S., Taylor, M., New, A.M.R. and Rodriguez, F. (2007) Uni-compartmental knee arthroplasty modelling. At 5th World Congress of Biomechanics, Munich, Germany, 29 Jul - 04 Aug 2006. Germany,

Hopkins, A.R., Taylor, M., Checa-Esteban, S., New, A.M.R. and Maletsky, L. (2007) Development of an FE model of a uni-compartmental knee replacement. At 7th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE2006), Antibes, France, 22 - 25 Mar 2006.

Hopkins, Andrew R., Hansen, Ulrich N., Amis, Andrew A., Knight, Lucy, Taylor, Mark, Levy, Ofer and Copeland, Stephen A. (2007) Wear in the prosthetic shoulder: association with design parameters. Journal of Biomechanical Engineering, 129, (2), 223-230. (doi:10.1115/1.2486060).

Hopkins, Andrew R., Hansen, Ulrich N., Amis, Andrew A., Taylor, Mark and Emery, Roger J. (2007) Glenohumeral kinematics following total shoulder arthroplasty: a finite element investigation. Journal of Orthopaedic Research, 25, (1), 108-115. (doi:10.1002/jor.20290).

Jeffers, Jonathan R.T., Browne, Martin, Lennon, Alexander B., Prendergast, Patrick J. and Taylor, Mark (2007) Cement mantle fatigue failure in total hip replacement: experimental and computational testing. Journal of Biomechanics, 39, (7), 1525-1533. (doi:10.1016/j.jbiomech.2006.07.029).

Jungmann, Ralf, Schitter, Georg, Fantner, Georg E., Lauer, Matthias E., Hansma, Paul K. and Thurner, Philipp J. (2007) Real-time microdamage and strain detection during micromechanical testing of single trabeculae. In, Experimental and Applied Mechanics: SEM Annual Conference and Exposition 2007 (3 Vols). Annual Meeting of the Society for Experimental Mechanics (SEM 2007) New York, USA, Curran Associates.

Kindt, J.H., Thurner, P.J., Lauer, M.E., Bosma, Bonnie, Schitter, Georg, Fantner, Georg E., Izumi, Michi, Weaver, James C., Morse, Daniel E. and Hansma, Paul K. (2007) In situ observation of fluoride-ion-induced hydroxyapatite–collagen detachment on bone fracture surfaces by atomic force microscopy. Nanotechnology, 18, (13), 135102-135110. (doi:10.1088/0957-4484/18/13/135102).

Knight, L.A. and Taylor, M. (2007) The effect of eccentric loading on the wear of total knee arthroplasty. In, 53rd Annual Meeting of the Orthopaedic Research Society, San Diego, USA, 11 - 14 Feb 2007. Orthopaedic Research Society.

Knight, Lucy A., Pal, Saikat, Coleman, John C., Bronson, Fred, Haider, Hani, Levine, Danny L., Taylor, Mark and Rullkoetter, Paul J. (2007) Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading. Journal of Biomechanics, 40, (7), 1550-1558. (doi:10.1016/j.jbiomech.2006.07.027).

Leung, S-Y, Browne, M. and New, A.M.R. (2007) Smooth surface micro finite element modelling of a cancellous bone analogue material. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine (In Press).

Leung, S-Y., Browne, M. and New, A.M.R. (2007) Smooth surface micro finite element modelling of a cancellous bone analogue material. In, European Society of Biomechanics Workshop 2007: Finite Element Modelling in Biomechanics and Mechanobiology, Dublin, Ireland, 26 - 28 Aug 2007. Dublin,

McNamara, Laoise M. and Prendergast, Patrcik J. (2007) Bone remodelling algorithms incorporating both strain and microdamage stimuli. Journal of Biomechanics, 40, (6), 1381-1391. (doi:10.1016/j.jbiomech.2006.05.007).

Mulvihill, B., McNamara, L.M. and Prendergast, P.J. (2007) Increases in the elastic modulus of trabecular bone tissue leads to more rapid perforation of trabeculae in osteoporotic bone. In, American Society of Mechanical Engineers: 2007 Summer Bioengineering Conference, Keystone, USA, 20 - 24 Jun 2007.

Mulvihill, B.M., McNamara, L.M. and Prendergast, P.J. (2007) 3D simulation of damage repair along a trabecular strut. At 53rd Annual Meeting of the Orthopaedic Research Society, San Diego, USA, 11 - 14 Feb 2007.

Pal, S., Haider, H., Laz, P., Knight, L.A. and Rullkoetter, P.J. (2007) Probabilistic computational modeling of total knee replacement wear. Wear, 7pp. (doi:10.1016/j.wear.2007.06.010).

Perillo-Marcone, A. and Taylor, M. (2007) Effect of varus/valgus malalignment on bone strains in the proximal tibia after TKR: an explicit finite element study. Journal of Biomechanical Engineering, 129, (1), 1-11. (doi:10.1115/1.2401177).

Radcliffe, I.A.J. and Taylor, M. (2007) Investigation into the affect of cementing techniques on load transfer in the resurfaced femoral head: a multi-femur FE based study. Clinical Biomechanics, 22, (4), 422-430. (doi:10.1016/j.clinbiomech.2006.12.001).

Radcliffe, I.A.J. and Taylor, M. (2007) Investigation into the effect of varus-valgus orientation on load transfer in the resurfaced femoral head: a multi-femur finite element analysis. Clinical Biomechanics, 22, (7), 780-786. (doi:10.1016/j.clinbiomech.2007.03.011).

Schitter, Georg, Astrom, Karl J., DeMartini, Barry E., Thurner, Philipp J., Turner, Kim L. and Hansma, Paul K. (2007) Design and modeling of a high-speed AFM -scanner. IEEE Transactions on Control Systems Technology, 15, (5), 906-915. (doi:10.1109/TCST.2007.902953).

Sengers, Bram G., Taylor, Mark, Please, Colin P. and Oreffo, Richard O.C. (2007) Computational modelling of cell spreading and tissue regeneration in porous scaffolds. Biomaterials, 28, (10), 1926-1940. (doi:10.1016/j.biomaterials.2006.12.008).

Thurner, Philipp J., Erickson, Blake, Jungmann, Ralf, Schriock, Zachary, Weaver, James C., Fantner, Georg E., Schitter, Georg, Morse, Daniel E. and Hansma, Paul K. (2007) High-speed photography of compressed human trabecular bone correlates whitening to microscopic damage. Engineering Fracture Mechanics, 74, (12), 1928-1941. (doi:10.1016/j.engfracmech.2006.05.024).

Thurner, Philipp J., Oroudjev, Emin, Jungmann, Ralf, Kreutz, Caitlin, Kindt, Johannes H., Schitter, Georg, Okouneva, Tatiana O., Lauer, Matthias E., Fantner, Georg E., Hansma, Helen and Hansma, Paul K. (2007) Imaging of bone ultrastructure using atomic force microscopy. In, Méndez-Vilas, A. and Díaz, J. (eds.) Modern Research and Educational Topics in Microscopy. , Formatex. (Microscopy Book Series 3). (In Press).

Wang, Yilin, McNamara, Laoise M., Schaffler, Mitchell B. and Weinbaum, Sheldon (2007) A model for the role of integrins in flow induced mechanotransduction in osteocytes. Proceedings of the National Academy of Sciences of the United States of America, 104, (40), 15941-15946. (doi:10.1073/pnas.0707246104).

Yin, H., Zhang, X., Pattrick, N., Klauke, N., Cordingley, H.C., Haswell, S.J. and Cooper, J.M. (2007) Influence of hydrodynamic conditions on quantitative cellular assays in microfluidic systems. Analytical Chemistry, 79, (18), 7139-7144. (doi:10.1021/ac071146k).

Zhang, X. and Haswell, S.J. (2007) Micro-fluidic and Lab-on-a-Chip technology. In, Seeberger, P.H. and Blume, T. (eds.) New Avenues to Efficient Chemical Synthesis: Emerging Technologies. Germany, Springer, 21-37. (Ernst Schering Foundation Symposium Proceedings, 2006/3). (Submitted). (doi:10.1007/2789_2007_026).

Zhurov, Alexei I., Limbert, Georges, Aeschlimann, Daniel P. and Middleton, John (2007) A constitutive model for the periodontal ligament as a compressible transversely isotropic visco-hyperelastic tissue. Computer Methods in Biomechanics and Biomedical Engineering, 10, (3), 223-235. (doi:10.1080/13639080701314894).

This list was generated on Wed Aug 27 01:27:51 2014 BST.