The University of Southampton
University of Southampton Institutional Repository

Particle geochemistry in the Rainbow hydrothermal plume, Mid-Atlantic Ridge1

Particle geochemistry in the Rainbow hydrothermal plume, Mid-Atlantic Ridge1
Particle geochemistry in the Rainbow hydrothermal plume, Mid-Atlantic Ridge1
We report the analysis of 18 large volume (500-1500 L) in situ filtered samples of particulate material from the largest hydrothermal plume on the Mid-Atlantic Ridge, overlying the ultramafic-hosted Rainbow hydrothermal field at 36[deg] 14'N. Measured particulate iron concentrations reach 614 nM. High concentrations of particulate Fe oxyhydroxides result from the extremely high Fe concentration (~24 mM) and Fe/H2S ratio (~24) of the vent fluids, and persist to at least 10 km away from the vent site due to the advection of plume material with the ambient along-axis flow. Two of the nine pairs of pump deployments appear to have intercepted the buoyant or otherwise very young portion of the hydrothermal plume. These samples are characterized by anomalously (compared to neutrally buoyant plume samples) high concentrations of Mg, U, and chalcophile elements, and low concentrations of Mn, Ca, V, Y, and the rare earth elements (REE). Within the neutrally buoyant plume, elemental distributions are largely consistent with previously observed behaviors: preferential removal of chalcophile elements, conservative behavior of oxyanions (P, V, and U), and continuous scavenging of Y and the REE. This consistency is particularly significant in light of the underlying differences in fluid chemistry between Rainbow and other studied sites. Chalcophile elements are preferentially removed from the plume in the order Cd>Zn>Co>Cu. Phosphorus/iron and vanadium/iron ratios for the neutrally buoyant plume are consistent with global trends with respect to the concentration of dissolved phosphate in ambient seawater. Comparison of buoyant and neutrally buoyant plume ratios with data from hydrothermal sediments underlying the Rainbow plume (Cave et al., 2002) indicates, however, that while P/Fe ratios are indeed constant V/Fe ratios increase progressively from early stage plume particles to sediments. REE distributions in the buoyant and neutrally buoyant plume appear most consistent with a continuous scavenging process during dispersion through the water column
0016-7037
759-772
Edmonds, H.N.
05662900-d907-4116-a632-5b9f731aaf34
German, C.R.
cd0eedd5-1377-4182-9c8a-b06aef8c1069
Edmonds, H.N.
05662900-d907-4116-a632-5b9f731aaf34
German, C.R.
cd0eedd5-1377-4182-9c8a-b06aef8c1069

Edmonds, H.N. and German, C.R. (2004) Particle geochemistry in the Rainbow hydrothermal plume, Mid-Atlantic Ridge1. Geochimica et Cosmochimica Acta, 68 (4), 759-772. (doi:10.1016/S0016-7037(03)00498-8).

Record type: Article

Abstract

We report the analysis of 18 large volume (500-1500 L) in situ filtered samples of particulate material from the largest hydrothermal plume on the Mid-Atlantic Ridge, overlying the ultramafic-hosted Rainbow hydrothermal field at 36[deg] 14'N. Measured particulate iron concentrations reach 614 nM. High concentrations of particulate Fe oxyhydroxides result from the extremely high Fe concentration (~24 mM) and Fe/H2S ratio (~24) of the vent fluids, and persist to at least 10 km away from the vent site due to the advection of plume material with the ambient along-axis flow. Two of the nine pairs of pump deployments appear to have intercepted the buoyant or otherwise very young portion of the hydrothermal plume. These samples are characterized by anomalously (compared to neutrally buoyant plume samples) high concentrations of Mg, U, and chalcophile elements, and low concentrations of Mn, Ca, V, Y, and the rare earth elements (REE). Within the neutrally buoyant plume, elemental distributions are largely consistent with previously observed behaviors: preferential removal of chalcophile elements, conservative behavior of oxyanions (P, V, and U), and continuous scavenging of Y and the REE. This consistency is particularly significant in light of the underlying differences in fluid chemistry between Rainbow and other studied sites. Chalcophile elements are preferentially removed from the plume in the order Cd>Zn>Co>Cu. Phosphorus/iron and vanadium/iron ratios for the neutrally buoyant plume are consistent with global trends with respect to the concentration of dissolved phosphate in ambient seawater. Comparison of buoyant and neutrally buoyant plume ratios with data from hydrothermal sediments underlying the Rainbow plume (Cave et al., 2002) indicates, however, that while P/Fe ratios are indeed constant V/Fe ratios increase progressively from early stage plume particles to sediments. REE distributions in the buoyant and neutrally buoyant plume appear most consistent with a continuous scavenging process during dispersion through the water column

This record has no associated files available for download.

More information

Published date: 2004

Identifiers

Local EPrints ID: 1366
URI: http://eprints.soton.ac.uk/id/eprint/1366
ISSN: 0016-7037
PURE UUID: a1166616-e0bf-43eb-8968-092f70ec7917

Catalogue record

Date deposited: 19 Apr 2004
Last modified: 15 Mar 2024 04:43

Export record

Altmetrics

Contributors

Author: H.N. Edmonds
Author: C.R. German

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×