The University of Southampton
University of Southampton Institutional Repository

Ultra-coherent signal output from an incoherent cw-pumped singly resonant optical parametric oscillator

Ultra-coherent signal output from an incoherent cw-pumped singly resonant optical parametric oscillator
Ultra-coherent signal output from an incoherent cw-pumped singly resonant optical parametric oscillator
Incoherent broad-bandwidth cw-pumped singly resonant optical parametric oscillator (OPO), in the quasi-phase-matched non-degenerate configuration, may efficiently generate ultra-coherent signal output by the convection-induced phase-locking mechanism in which the incoherence of the pump is absorbed by the idler wave allowing the signal to become highly coherent. In actual nonlinear quadratic waveguide configurations one obtains signal spectral widths smaller than 5×10-4 times the pump spectral width, and a reduction of the average signal intensity fluctuations by less than a factor 10-4.
0030-4018
437-449
Montes, C.
91c76863-ee0b-4631-9899-8efe418ecba9
Picozzi, A.
450f9a66-d279-4e86-8833-28b141264e38
Gallo, K.
d08fbf8e-a4f8-4c15-b485-3d4f731b8d27
Montes, C.
91c76863-ee0b-4631-9899-8efe418ecba9
Picozzi, A.
450f9a66-d279-4e86-8833-28b141264e38
Gallo, K.
d08fbf8e-a4f8-4c15-b485-3d4f731b8d27

Montes, C., Picozzi, A. and Gallo, K. (2004) Ultra-coherent signal output from an incoherent cw-pumped singly resonant optical parametric oscillator. Optics Communications, 237 (4-6), 437-449. (doi:10.1016/j.optcom.2004.04.017).

Record type: Article

Abstract

Incoherent broad-bandwidth cw-pumped singly resonant optical parametric oscillator (OPO), in the quasi-phase-matched non-degenerate configuration, may efficiently generate ultra-coherent signal output by the convection-induced phase-locking mechanism in which the incoherence of the pump is absorbed by the idler wave allowing the signal to become highly coherent. In actual nonlinear quadratic waveguide configurations one obtains signal spectral widths smaller than 5×10-4 times the pump spectral width, and a reduction of the average signal intensity fluctuations by less than a factor 10-4.

This record has no associated files available for download.

More information

Published date: 2004

Identifiers

Local EPrints ID: 13903
URI: http://eprints.soton.ac.uk/id/eprint/13903
ISSN: 0030-4018
PURE UUID: 463675ef-9edf-46d2-9d2c-940f1649a3b3

Catalogue record

Date deposited: 22 Dec 2004
Last modified: 15 Mar 2024 05:14

Export record

Altmetrics

Contributors

Author: C. Montes
Author: A. Picozzi
Author: K. Gallo

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×