High spatial resolution microwave detection system for Brillouin-based distributed temperature and strain sensors

High spatial resolution microwave detection system for Brillouin-based distributed temperature and strain sensors
High spatial resolution microwave detection system for Brillouin-based distributed temperature and strain sensors
We present a microwave detection system for coherent detection of spontaneous Brillouin-based distributed temperature and strain measurements. The system was designed to overcome the existing bandwidth limitations of a previously used commercial spectrum analyser and provide a commercially practical solution to the detection of the Brillouin frequency shift and intensity for long range high spatial resolution measurements. The detection system bandwidth corresponds to a potential spatial resolution of ~60 cm. The system was demonstrated as a temperature sensor over a range of 30 km, with a temperature resolution of 1.6 °C and spatial resolution of ~2 m. It was also demonstrated as a combined temperature and strain sensor over a range of 6.3 km with ~1.3 m spatial resolution; temperature and strain resolutions of 3 °C and 80 µε respectively were achieved.
0957-0233
1539-1543
Al Ahbabi, Mohammed Nasser
263cce3f-d0d9-4bce-b0f6-7628853073ea
Lawrence, N.P.
5b5e4062-5aee-4514-8f76-3147c0db1c93
Cho, Y.T.
eea77b90-e7f3-4496-9637-721dfe8fb5a4
Newson, T.P.
6735857e-d947-45ec-8163-54ebb25daad7
Al Ahbabi, Mohammed Nasser
263cce3f-d0d9-4bce-b0f6-7628853073ea
Lawrence, N.P.
5b5e4062-5aee-4514-8f76-3147c0db1c93
Cho, Y.T.
eea77b90-e7f3-4496-9637-721dfe8fb5a4
Newson, T.P.
6735857e-d947-45ec-8163-54ebb25daad7

Al Ahbabi, Mohammed Nasser, Lawrence, N.P., Cho, Y.T. and Newson, T.P. (2004) High spatial resolution microwave detection system for Brillouin-based distributed temperature and strain sensors. Measurement Science and Technology, 15 (8), 1539-1543. (doi:10.1088/0957-0233/15/8/019).

Record type: Article

Abstract

We present a microwave detection system for coherent detection of spontaneous Brillouin-based distributed temperature and strain measurements. The system was designed to overcome the existing bandwidth limitations of a previously used commercial spectrum analyser and provide a commercially practical solution to the detection of the Brillouin frequency shift and intensity for long range high spatial resolution measurements. The detection system bandwidth corresponds to a potential spatial resolution of ~60 cm. The system was demonstrated as a temperature sensor over a range of 30 km, with a temperature resolution of 1.6 °C and spatial resolution of ~2 m. It was also demonstrated as a combined temperature and strain sensor over a range of 6.3 km with ~1.3 m spatial resolution; temperature and strain resolutions of 3 °C and 80 µε respectively were achieved.

Text
2872 - Author's Original
Download (491kB)

More information

Published date: 2004

Identifiers

Local EPrints ID: 13915
URI: http://eprints.soton.ac.uk/id/eprint/13915
ISSN: 0957-0233
PURE UUID: 9e074a66-671c-444d-add0-4e9db0db5fd8

Catalogue record

Date deposited: 13 Jan 2005
Last modified: 15 Mar 2024 05:15

Export record

Altmetrics

Contributors

Author: Mohammed Nasser Al Ahbabi
Author: N.P. Lawrence
Author: Y.T. Cho
Author: T.P. Newson

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×