Auditory evoked potentials for monitoring during anaesthesia: a study of data quality

Auditory evoked potentials for monitoring during anaesthesia: a study of data quality
Auditory evoked potentials for monitoring during anaesthesia: a study of data quality
The auditory evoked potential termed the middle latency response (MLR) has been suggested as an indicator of adequacy of anaesthesia during surgery. However, the response is small and must be extracted from high levels of background noise. A key consideration in using the MLR for clinical monitoring is whether data quality is sufficient to detect small changes. The aim of this study was to investigate the quality of the MLR recorded during anaesthesia, as a rigorous analysis of data quality is lacking in many studies. MLR recordings from patients sedated in intensive care after cardiac surgery were compared to recordings from a reference group of young volunteers with normal hearing. Data quality was measured with the Fsp parameter. A bootstrap analysis was used to measure statistical response presence and to detect within-subject changes during clinical anaesthesia. Noise levels were high in the normative group probably due to myogenic and EEG activity. With 5 Hz click stimulation, MLR presence in the normative group was below 30%. Response presence improved using stimulation paradigms with chirps or maximum length sequences and reached 100% with a combination of maximum length sequences and chirps. Fsp values generally improved during anaesthesia as noise levels reduced and MLR presence was 100% for MLS click stimulation. Changes in the MLR amplitude with propofol infusion rate were small. Some within-subject changes in MLR amplitude were detected using the bootstrap analysis, but 100% detection was not possible. Conclusion: Obtaining good quality MLR data in awake subjects is challenging. Data quality improves during clinical anaesthesia and with advanced stimulation methods, but reliable detection of changes in the MLR for clinical monitoring remains a challenge.
anaesthesia, auditory evoked potentials, depth of anaesthesia, middle latency response, quality
1350-4533
168-173
Notley, S.V.
3a5a223e-3123-41b9-b7ae-65dfcb20d782
Bell, S.L.
91de0801-d2b7-44ba-8e8e-523e672aed8a
Smith, D.C.
217b19f1-7588-4d54-a062-8394eea6dea1
Notley, S.V.
3a5a223e-3123-41b9-b7ae-65dfcb20d782
Bell, S.L.
91de0801-d2b7-44ba-8e8e-523e672aed8a
Smith, D.C.
217b19f1-7588-4d54-a062-8394eea6dea1

Notley, S.V., Bell, S.L. and Smith, D.C. (2010) Auditory evoked potentials for monitoring during anaesthesia: a study of data quality. Medical Engineering & Physics, 32 (2), 168-173. (doi:10.1016/j.medengphy.2009.11.006).

Record type: Article

Abstract

The auditory evoked potential termed the middle latency response (MLR) has been suggested as an indicator of adequacy of anaesthesia during surgery. However, the response is small and must be extracted from high levels of background noise. A key consideration in using the MLR for clinical monitoring is whether data quality is sufficient to detect small changes. The aim of this study was to investigate the quality of the MLR recorded during anaesthesia, as a rigorous analysis of data quality is lacking in many studies. MLR recordings from patients sedated in intensive care after cardiac surgery were compared to recordings from a reference group of young volunteers with normal hearing. Data quality was measured with the Fsp parameter. A bootstrap analysis was used to measure statistical response presence and to detect within-subject changes during clinical anaesthesia. Noise levels were high in the normative group probably due to myogenic and EEG activity. With 5 Hz click stimulation, MLR presence in the normative group was below 30%. Response presence improved using stimulation paradigms with chirps or maximum length sequences and reached 100% with a combination of maximum length sequences and chirps. Fsp values generally improved during anaesthesia as noise levels reduced and MLR presence was 100% for MLS click stimulation. Changes in the MLR amplitude with propofol infusion rate were small. Some within-subject changes in MLR amplitude were detected using the bootstrap analysis, but 100% detection was not possible. Conclusion: Obtaining good quality MLR data in awake subjects is challenging. Data quality improves during clinical anaesthesia and with advanced stimulation methods, but reliable detection of changes in the MLR for clinical monitoring remains a challenge.

This record has no associated files available for download.

More information

Published date: March 2010
Keywords: anaesthesia, auditory evoked potentials, depth of anaesthesia, middle latency response, quality
Organisations: Human Sciences Group

Identifiers

Local EPrints ID: 145259
URI: http://eprints.soton.ac.uk/id/eprint/145259
ISSN: 1350-4533
PURE UUID: ffffd914-b527-49d3-8a26-b3e14be808c5

Catalogue record

Date deposited: 16 Apr 2010 15:07
Last modified: 14 Mar 2024 00:50

Export record

Altmetrics

Contributors

Author: S.V. Notley
Author: S.L. Bell
Author: D.C. Smith

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×