High flow rate microfluidic device for blood plasma separation using a range of temperatures

High flow rate microfluidic device for blood plasma separation using a range of temperatures
High flow rate microfluidic device for blood plasma separation using a range of temperatures
A hybrid microfluidic device that uses hydrodynamic forces to separate human plasma from blood cells has been designed and fabricated and the advantageous effects of temperature and flow rates are investigated in this paper. The blood separating device includes an inlet which is reduced by approximately 20 times to a small constrictor channel, which then opens out to a larger output channel with a small lateral channel for the collection of plasma. When tested the device separated plasma from whole blood using a wide range of flow rates, between 50 µl min-1 and 200 µl min-1, at the higher flow rates injected by hand and at temperatures ranging from 23 °C to 50 °C, the latter resulting in an increase in the cell-free layer of up to 250%. It was also tested continuously using between 5% and 40% erythrocytes in plasma and whole blood without blocking the channels or hemolysis of the cells. The mean percentage of plasma collected after separation was 3.47% from a sample of 1 ml. The percentage of cells removed from the plasma varied depending on the flow rate used, but at 37 °C ranged between 95.4 ± 1% and 97.05 ± 05% at 100 µl min-1 and 200 µl min-1, respectively. The change in temperature also had an effect on the number of cells removed from the plasma which was between 93.5 ± 0.65% and 97.01 ± 0.3% at 26.9 °C and 37 °C, respectively, using a flow rate of 100 µl min-1. Due to its ability to operate in a wide range of conditions, it is envisaged that this device can be used in in vitrolab on a chip applications, as well as a hand-held point of care (POC) device
1473-0197
211-219
Rodríguez-Villarreal, Angeles Ivón
e14ddfb7-904a-4084-bb09-98751c7f097b
Arundell, Martin
e24d3405-a436-4d65-a6e4-2939ede79678
Carmona, Manuel
c0ab8712-151a-4dd6-8fd9-f28ef8284387
Samitier, Josep
7735286e-85a5-4b4d-b8af-2826e1441b77
Rodríguez-Villarreal, Angeles Ivón
e14ddfb7-904a-4084-bb09-98751c7f097b
Arundell, Martin
e24d3405-a436-4d65-a6e4-2939ede79678
Carmona, Manuel
c0ab8712-151a-4dd6-8fd9-f28ef8284387
Samitier, Josep
7735286e-85a5-4b4d-b8af-2826e1441b77

Rodríguez-Villarreal, Angeles Ivón, Arundell, Martin, Carmona, Manuel and Samitier, Josep (2010) High flow rate microfluidic device for blood plasma separation using a range of temperatures. Lab on a Chip, 10, 211-219. (doi:10.1039/b904531g).

Record type: Article

Abstract

A hybrid microfluidic device that uses hydrodynamic forces to separate human plasma from blood cells has been designed and fabricated and the advantageous effects of temperature and flow rates are investigated in this paper. The blood separating device includes an inlet which is reduced by approximately 20 times to a small constrictor channel, which then opens out to a larger output channel with a small lateral channel for the collection of plasma. When tested the device separated plasma from whole blood using a wide range of flow rates, between 50 µl min-1 and 200 µl min-1, at the higher flow rates injected by hand and at temperatures ranging from 23 °C to 50 °C, the latter resulting in an increase in the cell-free layer of up to 250%. It was also tested continuously using between 5% and 40% erythrocytes in plasma and whole blood without blocking the channels or hemolysis of the cells. The mean percentage of plasma collected after separation was 3.47% from a sample of 1 ml. The percentage of cells removed from the plasma varied depending on the flow rate used, but at 37 °C ranged between 95.4 ± 1% and 97.05 ± 05% at 100 µl min-1 and 200 µl min-1, respectively. The change in temperature also had an effect on the number of cells removed from the plasma which was between 93.5 ± 0.65% and 97.01 ± 0.3% at 26.9 °C and 37 °C, respectively, using a flow rate of 100 µl min-1. Due to its ability to operate in a wide range of conditions, it is envisaged that this device can be used in in vitrolab on a chip applications, as well as a hand-held point of care (POC) device

This record has no associated files available for download.

More information

Published date: 2010

Identifiers

Local EPrints ID: 155791
URI: http://eprints.soton.ac.uk/id/eprint/155791
ISSN: 1473-0197
PURE UUID: 7fcdf39e-bcbf-4958-8954-4ccb6fe4d75c

Catalogue record

Date deposited: 28 May 2010 13:45
Last modified: 14 Mar 2024 01:40

Export record

Altmetrics

Contributors

Author: Angeles Ivón Rodríguez-Villarreal
Author: Martin Arundell
Author: Manuel Carmona
Author: Josep Samitier

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×