PURPOSE: To evaluate the effect of powered brushing with the Sonicare electronic toothbrush on the structure and thickness reduction of S. mutans biofilms using digital time-lapse microscopy (DTLM) and confocal microscopy (CM) techniques. MATERIALS AND METHODS: S. mutans biofilms grown on glass microscope slides on BHI and 2% sucrose were exposed to Sonicare for 15 seconds with the bristle tips just contacting the slide, and at distances of 0.5, 1.0, and 1.5 mm above the slide. RESULTS: With direct bristle contact, the reduction in biofilm thickness was greater than 99%. DTLM showed the break up and detachment of biofilm caused by the shear forces generated by the rapid bristle motion in real time. The Sonicare was shown to significantly reduce biofilm thickness even when the bristles were 1 mm above the biofilm. The percent biofilm thickness reduction was inversely proportional to the bristle distance. This study demonstrates the Sonicare toothbrush effectively removed biofilm from hard flat surfaces both by direct bristle contact and by fluid dynamic shear forces alone.
79-83
Heersink, Joanna
8f115aac-87fd-4d8d-9849-500c7f311efd
Costerton, William J.
4bb46d6e-2305-4799-b524-d84d2f99816a
Stoodley, Paul
08614665-92a9-4466-806e-20c6daeb483f
April 2003
Heersink, Joanna
8f115aac-87fd-4d8d-9849-500c7f311efd
Costerton, William J.
4bb46d6e-2305-4799-b524-d84d2f99816a
Stoodley, Paul
08614665-92a9-4466-806e-20c6daeb483f
Heersink, Joanna, Costerton, William J. and Stoodley, Paul
(2003)
Influence of the Sonicare toothbrush on the structure and thickness of laboratory grown Streptococcus mutans biofilms.
American Journal of Dentistry, 16 (2), .
Abstract
PURPOSE: To evaluate the effect of powered brushing with the Sonicare electronic toothbrush on the structure and thickness reduction of S. mutans biofilms using digital time-lapse microscopy (DTLM) and confocal microscopy (CM) techniques. MATERIALS AND METHODS: S. mutans biofilms grown on glass microscope slides on BHI and 2% sucrose were exposed to Sonicare for 15 seconds with the bristle tips just contacting the slide, and at distances of 0.5, 1.0, and 1.5 mm above the slide. RESULTS: With direct bristle contact, the reduction in biofilm thickness was greater than 99%. DTLM showed the break up and detachment of biofilm caused by the shear forces generated by the rapid bristle motion in real time. The Sonicare was shown to significantly reduce biofilm thickness even when the bristles were 1 mm above the biofilm. The percent biofilm thickness reduction was inversely proportional to the bristle distance. This study demonstrates the Sonicare toothbrush effectively removed biofilm from hard flat surfaces both by direct bristle contact and by fluid dynamic shear forces alone.
This record has no associated files available for download.
More information
Published date: April 2003
Organisations:
Engineering Mats & Surface Engineerg Gp
Identifiers
Local EPrints ID: 157129
URI: http://eprints.soton.ac.uk/id/eprint/157129
ISSN: 0894-8275
PURE UUID: 8d44d2c1-840a-4eed-885d-bbdd7705c14c
Catalogue record
Date deposited: 09 Jun 2010 11:36
Last modified: 09 Jan 2022 03:32
Export record
Contributors
Author:
Joanna Heersink
Author:
William J. Costerton
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics