Poroelasticity: Finite element modelling of anomalous tilt and pore pressure caused by pumping in a sedimentary half space with fault
Poroelasticity: Finite element modelling of anomalous tilt and pore pressure caused by pumping in a sedimentary half space with fault
Extraction of groundwater or hydrocarbons causes pore pressure gradients and soil deformation due to poroelastic coupling. Recent studies show that high-resolution engineering tiltmeters installed at shallow depth between 2 ? 10m resolve this deformation.
Models using poroelasticity can describe the relationship between fluid extraction, pore pressure gradients and induced tilt for homogeneous and layered sedimentary half spaces. Faults intersecting a stack of sedimentary layers, for example in the Lower-Rhine-Embayment, are of fundamental impact to the groundwater flow system of an area. However, the fault’s hydromechanical effect on pump induced tilt and the pore pressure regime is still poorly investigated. We chose a comparatively simple approach to quantify anomalous pump induced tilt and pore pressure observed near a fault and close to the surface in a sedimentary subsoil. A PC-based Finite Element software is used to model poroelastic deformation, i.e. modelling vertical tilt and excess pore pressure in response to fluid extraction through a singular well. We compare numerical solutions for models with and without faults and show that a fault can modify symmetry and amplitude of the deformation field by more than a magnitude.
We conclude that tilt and pore pressure measurements also at shallow depth can thus be biased by large subsurface structures like faults. Vice versa, these measurements may provide means to quantify hydromechanical effects caused by subsurface structures. However, depending on the geological setting, i.e. if pathways are established by a fault, the anomaly caused by the fault can also be small and hard to detect. Therefore, faults and geological structures like material boundaries have to be considered in poroelastic models carefully. For tilt surveys with a limited number of instruments in geologically well constrained areas these models allow the preselection of potential positions for tiltmeters where prominent field anomalies are expected.
219-232
Urlaub, Morelia
f5a21932-9794-4008-b0a9-72bb366098b8
Fabian, Marcus
0f3b5881-10ba-485b-a915-c816ccfcfb72
April 2011
Urlaub, Morelia
f5a21932-9794-4008-b0a9-72bb366098b8
Fabian, Marcus
0f3b5881-10ba-485b-a915-c816ccfcfb72
Urlaub, Morelia and Fabian, Marcus
(2011)
Poroelasticity: Finite element modelling of anomalous tilt and pore pressure caused by pumping in a sedimentary half space with fault.
Journal of Geodynamics, 51 (4), .
(doi:10.1016/j.jog.2010.09.001).
Abstract
Extraction of groundwater or hydrocarbons causes pore pressure gradients and soil deformation due to poroelastic coupling. Recent studies show that high-resolution engineering tiltmeters installed at shallow depth between 2 ? 10m resolve this deformation.
Models using poroelasticity can describe the relationship between fluid extraction, pore pressure gradients and induced tilt for homogeneous and layered sedimentary half spaces. Faults intersecting a stack of sedimentary layers, for example in the Lower-Rhine-Embayment, are of fundamental impact to the groundwater flow system of an area. However, the fault’s hydromechanical effect on pump induced tilt and the pore pressure regime is still poorly investigated. We chose a comparatively simple approach to quantify anomalous pump induced tilt and pore pressure observed near a fault and close to the surface in a sedimentary subsoil. A PC-based Finite Element software is used to model poroelastic deformation, i.e. modelling vertical tilt and excess pore pressure in response to fluid extraction through a singular well. We compare numerical solutions for models with and without faults and show that a fault can modify symmetry and amplitude of the deformation field by more than a magnitude.
We conclude that tilt and pore pressure measurements also at shallow depth can thus be biased by large subsurface structures like faults. Vice versa, these measurements may provide means to quantify hydromechanical effects caused by subsurface structures. However, depending on the geological setting, i.e. if pathways are established by a fault, the anomaly caused by the fault can also be small and hard to detect. Therefore, faults and geological structures like material boundaries have to be considered in poroelastic models carefully. For tilt surveys with a limited number of instruments in geologically well constrained areas these models allow the preselection of potential positions for tiltmeters where prominent field anomalies are expected.
Text
UrlaubFabian2011.pdf
- Other
Restricted to Registered users only
More information
Published date: April 2011
Identifiers
Local EPrints ID: 169577
URI: http://eprints.soton.ac.uk/id/eprint/169577
ISSN: 0264-3707
PURE UUID: c2e10e8c-7425-455f-aaff-75f3a093c40a
Catalogue record
Date deposited: 16 Dec 2010 16:22
Last modified: 14 Mar 2024 02:21
Export record
Altmetrics
Contributors
Author:
Morelia Urlaub
Author:
Marcus Fabian
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics