The University of Southampton
University of Southampton Institutional Repository

Chloride fluxes in lily pollen tubes: a critical reevaluation

Chloride fluxes in lily pollen tubes: a critical reevaluation
Chloride fluxes in lily pollen tubes: a critical reevaluation
Microelectrodes, made from a Cl?-selective liquid ion exchanger previously used to measure putative Cl- fluxes in Lilium longiflorum pollen tubes, were characterized. The electrodes were poorly selective, possessing only about 10-fold selectivity for Cl? over other anions tested. They had only 2.4-fold selectivity for Cl? over the anionic form of the H+ buffer, MES, indicating that the electrode can indirectly detect H+ gradients. Apparent anion influx was detected along the pollen tube shafts and at the grains while apparent anion efflux was detected near the tip of the tube. During oscillating growth, the peak of the oscillating apparent anion efflux at the tip occurred, on average, 7.9 sec after the peak of the growth oscillations. Consideration of the previously characterized H+ fluxes in lily pollen grains and tubes, as well as the poor anion selectivity of the Cl? electrodes, indicates that the putative Cl? fluxes are in fact changes in the anionic concentration of the buffer resulting from H+ gradients and not changes in Cl? concentration. The claim of a central role for Cl? in lily pollen tube growth is further undermined by the fact that these tubes grow at the same rate if the Cl? content of the growth medium is reduced to trace levels (?31 ?m), and that the grains have only small reserves of Cl?. These results lead to the conclusion that Cl? fluxes are not a significant component of pollen tube growth and Cl? itself is not required for growth
0960-7412
799-812
Messerli, Mark A.
94a8bd34-95d7-4a52-b4d8-1ccded0e8fe7
Smith, Peter J.S.
003de469-9420-4f12-8f0e-8e8d76d28d6c
Lewis, Robert C.
ae4255c9-e68b-4f7d-b772-dc5156881343
Robinson, Kenneth R.
c4cc409c-7cb9-4370-878f-cf20ec3b7fdc
Messerli, Mark A.
94a8bd34-95d7-4a52-b4d8-1ccded0e8fe7
Smith, Peter J.S.
003de469-9420-4f12-8f0e-8e8d76d28d6c
Lewis, Robert C.
ae4255c9-e68b-4f7d-b772-dc5156881343
Robinson, Kenneth R.
c4cc409c-7cb9-4370-878f-cf20ec3b7fdc

Messerli, Mark A., Smith, Peter J.S., Lewis, Robert C. and Robinson, Kenneth R. (2004) Chloride fluxes in lily pollen tubes: a critical reevaluation. The Plant Journal, 40 (5), 799-812. (doi:10.1111/j.1365-313X.2004.02252.x). (PMID:15546362)

Record type: Article

Abstract

Microelectrodes, made from a Cl?-selective liquid ion exchanger previously used to measure putative Cl- fluxes in Lilium longiflorum pollen tubes, were characterized. The electrodes were poorly selective, possessing only about 10-fold selectivity for Cl? over other anions tested. They had only 2.4-fold selectivity for Cl? over the anionic form of the H+ buffer, MES, indicating that the electrode can indirectly detect H+ gradients. Apparent anion influx was detected along the pollen tube shafts and at the grains while apparent anion efflux was detected near the tip of the tube. During oscillating growth, the peak of the oscillating apparent anion efflux at the tip occurred, on average, 7.9 sec after the peak of the growth oscillations. Consideration of the previously characterized H+ fluxes in lily pollen grains and tubes, as well as the poor anion selectivity of the Cl? electrodes, indicates that the putative Cl? fluxes are in fact changes in the anionic concentration of the buffer resulting from H+ gradients and not changes in Cl? concentration. The claim of a central role for Cl? in lily pollen tube growth is further undermined by the fact that these tubes grow at the same rate if the Cl? content of the growth medium is reduced to trace levels (?31 ?m), and that the grains have only small reserves of Cl?. These results lead to the conclusion that Cl? fluxes are not a significant component of pollen tube growth and Cl? itself is not required for growth

Text
j.1365-313X.2004.02252.x.pdf - Other
Download (298kB)

More information

Published date: December 2004
Organisations: University of Southampton

Identifiers

Local EPrints ID: 188827
URI: http://eprints.soton.ac.uk/id/eprint/188827
ISSN: 0960-7412
PURE UUID: 8cdc56ba-123f-4d2e-b3ce-d44fb14e943f
ORCID for Peter J.S. Smith: ORCID iD orcid.org/0000-0003-4400-6853

Catalogue record

Date deposited: 06 Jun 2011 09:02
Last modified: 15 Mar 2024 03:38

Export record

Altmetrics

Contributors

Author: Mark A. Messerli
Author: Robert C. Lewis
Author: Kenneth R. Robinson

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×