The University of Southampton
University of Southampton Institutional Repository

Test retest reliability of the oxygen uptake efficiency slope in surgical patients

Test retest reliability of the oxygen uptake efficiency slope in surgical patients
Test retest reliability of the oxygen uptake efficiency slope in surgical patients
The oxygen uptake efficiency slope is a measure of cardiopulmonary fitness, that can be obtained from a sub-maximal cardiopulmonary exercise test. It has been evaluated in medical patients but its reliability in surgical populations remains uncertain. We conducted a test–retest study with the aim of establishing the reliability of the oxygen uptake efficiency slope in relation to that of the anaerobic threshold and peak oxygen uptake, in general surgical patients. Twenty-six patients over 60 years old completed two symptom-limited, incremental cycle ergometry tests within 7 days. The mean (SD) anaerobic threshold was 13.0 (3.0) mlO2.kg?1.min?1. There were no significant differences between mean test and retest values of anaerobic threshold (p = 0.50), peak oxygen uptake (p = 0.76) or oxygen uptake efficiency slope (p = 0.42). Reliability coefficients (95% CI) for the anaerobic threshold, oxygen uptake efficiency slope and peak oxygen uptake were 66.7% (45.3–87.9%), 89.0% (81.0–96.9%) and 91.7% (85.7–97.8%), respectively. The oxygen uptake efficiency slope was determined easily in all patients and found to have excellent reliability. Its clinical utility in determining pre-operative fitness warrants further evaluation.

0003-2409
659-666
Phypers, B.J.
41150af4-10fb-4554-ba5b-c122ea9dd76e
Robiony-Rogers, D.
1e18f82d-82f7-4388-b954-25a7973bc8ed
Pickering, R.M.
4a828314-7ddf-4f96-abed-3407017d4c90
Garden, A.L.
0433913b-c370-4be7-8951-2c5ae8287813
Phypers, B.J.
41150af4-10fb-4554-ba5b-c122ea9dd76e
Robiony-Rogers, D.
1e18f82d-82f7-4388-b954-25a7973bc8ed
Pickering, R.M.
4a828314-7ddf-4f96-abed-3407017d4c90
Garden, A.L.
0433913b-c370-4be7-8951-2c5ae8287813

Phypers, B.J., Robiony-Rogers, D., Pickering, R.M. and Garden, A.L. (2011) Test retest reliability of the oxygen uptake efficiency slope in surgical patients. Anaesthesia, 66 (8), 659-666. (doi:10.1111/j.1365-2044.2011.06714.x). (PMID:21707558)

Record type: Article

Abstract

The oxygen uptake efficiency slope is a measure of cardiopulmonary fitness, that can be obtained from a sub-maximal cardiopulmonary exercise test. It has been evaluated in medical patients but its reliability in surgical populations remains uncertain. We conducted a test–retest study with the aim of establishing the reliability of the oxygen uptake efficiency slope in relation to that of the anaerobic threshold and peak oxygen uptake, in general surgical patients. Twenty-six patients over 60 years old completed two symptom-limited, incremental cycle ergometry tests within 7 days. The mean (SD) anaerobic threshold was 13.0 (3.0) mlO2.kg?1.min?1. There were no significant differences between mean test and retest values of anaerobic threshold (p = 0.50), peak oxygen uptake (p = 0.76) or oxygen uptake efficiency slope (p = 0.42). Reliability coefficients (95% CI) for the anaerobic threshold, oxygen uptake efficiency slope and peak oxygen uptake were 66.7% (45.3–87.9%), 89.0% (81.0–96.9%) and 91.7% (85.7–97.8%), respectively. The oxygen uptake efficiency slope was determined easily in all patients and found to have excellent reliability. Its clinical utility in determining pre-operative fitness warrants further evaluation.

This record has no associated files available for download.

More information

Published date: 24 June 2011
Organisations: Primary Care & Population Sciences

Identifiers

Local EPrints ID: 195765
URI: http://eprints.soton.ac.uk/id/eprint/195765
ISSN: 0003-2409
PURE UUID: f687ccb3-f26c-4f1c-9588-37236ce9f456

Catalogue record

Date deposited: 26 Aug 2011 12:25
Last modified: 14 Mar 2024 04:06

Export record

Altmetrics

Contributors

Author: B.J. Phypers
Author: D. Robiony-Rogers
Author: R.M. Pickering
Author: A.L. Garden

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×