Test retest reliability of the oxygen uptake efficiency slope in surgical patients
Test retest reliability of the oxygen uptake efficiency slope in surgical patients
The oxygen uptake efficiency slope is a measure of cardiopulmonary fitness, that can be obtained from a sub-maximal cardiopulmonary exercise test. It has been evaluated in medical patients but its reliability in surgical populations remains uncertain. We conducted a test–retest study with the aim of establishing the reliability of the oxygen uptake efficiency slope in relation to that of the anaerobic threshold and peak oxygen uptake, in general surgical patients. Twenty-six patients over 60 years old completed two symptom-limited, incremental cycle ergometry tests within 7 days. The mean (SD) anaerobic threshold was 13.0 (3.0) mlO2.kg?1.min?1. There were no significant differences between mean test and retest values of anaerobic threshold (p = 0.50), peak oxygen uptake (p = 0.76) or oxygen uptake efficiency slope (p = 0.42). Reliability coefficients (95% CI) for the anaerobic threshold, oxygen uptake efficiency slope and peak oxygen uptake were 66.7% (45.3–87.9%), 89.0% (81.0–96.9%) and 91.7% (85.7–97.8%), respectively. The oxygen uptake efficiency slope was determined easily in all patients and found to have excellent reliability. Its clinical utility in determining pre-operative fitness warrants further evaluation.
659-666
Phypers, B.J.
41150af4-10fb-4554-ba5b-c122ea9dd76e
Robiony-Rogers, D.
1e18f82d-82f7-4388-b954-25a7973bc8ed
Pickering, R.M.
4a828314-7ddf-4f96-abed-3407017d4c90
Garden, A.L.
0433913b-c370-4be7-8951-2c5ae8287813
24 June 2011
Phypers, B.J.
41150af4-10fb-4554-ba5b-c122ea9dd76e
Robiony-Rogers, D.
1e18f82d-82f7-4388-b954-25a7973bc8ed
Pickering, R.M.
4a828314-7ddf-4f96-abed-3407017d4c90
Garden, A.L.
0433913b-c370-4be7-8951-2c5ae8287813
Abstract
The oxygen uptake efficiency slope is a measure of cardiopulmonary fitness, that can be obtained from a sub-maximal cardiopulmonary exercise test. It has been evaluated in medical patients but its reliability in surgical populations remains uncertain. We conducted a test–retest study with the aim of establishing the reliability of the oxygen uptake efficiency slope in relation to that of the anaerobic threshold and peak oxygen uptake, in general surgical patients. Twenty-six patients over 60 years old completed two symptom-limited, incremental cycle ergometry tests within 7 days. The mean (SD) anaerobic threshold was 13.0 (3.0) mlO2.kg?1.min?1. There were no significant differences between mean test and retest values of anaerobic threshold (p = 0.50), peak oxygen uptake (p = 0.76) or oxygen uptake efficiency slope (p = 0.42). Reliability coefficients (95% CI) for the anaerobic threshold, oxygen uptake efficiency slope and peak oxygen uptake were 66.7% (45.3–87.9%), 89.0% (81.0–96.9%) and 91.7% (85.7–97.8%), respectively. The oxygen uptake efficiency slope was determined easily in all patients and found to have excellent reliability. Its clinical utility in determining pre-operative fitness warrants further evaluation.
This record has no associated files available for download.
More information
Published date: 24 June 2011
Organisations:
Primary Care & Population Sciences
Identifiers
Local EPrints ID: 195765
URI: http://eprints.soton.ac.uk/id/eprint/195765
ISSN: 0003-2409
PURE UUID: f687ccb3-f26c-4f1c-9588-37236ce9f456
Catalogue record
Date deposited: 26 Aug 2011 12:25
Last modified: 14 Mar 2024 04:06
Export record
Altmetrics
Contributors
Author:
B.J. Phypers
Author:
D. Robiony-Rogers
Author:
A.L. Garden
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics