The University of Southampton
University of Southampton Institutional Repository

Tribological behaviour a-C and a-C:H films doped with Ti in biological solutions

Tribological behaviour a-C and a-C:H films doped with Ti in biological solutions
Tribological behaviour a-C and a-C:H films doped with Ti in biological solutions
The coatings were deposited in a multi magnetron Teer sputtering device with two C targets and a Ti target in Ar atmosphere, on steel and Si substrates. To deposit hydrogenated coatings methane was introduced in the discharge atmosphere. The films were deposited in a range of 7–14 at.% Ti content. X-ray diffraction patterns revealed the presence of a nanocrystalline TiC phase. The hardness varied from 8 to 9 GPa. The tribological tests were performed under dry sliding and lubricated (0.9% NaCl water solution, physiological solution, PS, and 10% fetal bovine serum dissolved in Ringer’s saline solution, FBS) conditions, using a 100Cr6 steel balls with a diameter of 6 mm, in a pin-on-disc wear test apparatus.

0042-207X
1144-1148
Escudeiro, Ana
6b4708dc-6e5f-4b7f-95a6-423b8be52b7e
Polcar, Tomas
c669b663-3ba9-4e7b-9f97-8ef5655ac6d2
Cavaleiro, Albano
83fb0417-34af-4c14-b4b4-b9541e4fc652
Escudeiro, Ana
6b4708dc-6e5f-4b7f-95a6-423b8be52b7e
Polcar, Tomas
c669b663-3ba9-4e7b-9f97-8ef5655ac6d2
Cavaleiro, Albano
83fb0417-34af-4c14-b4b4-b9541e4fc652

Escudeiro, Ana, Polcar, Tomas and Cavaleiro, Albano (2011) Tribological behaviour a-C and a-C:H films doped with Ti in biological solutions. Vacuum, 85 (12), 1144-1148. (doi:10.1016/j.vacuum.2011.03.011).

Record type: Article

Abstract

The coatings were deposited in a multi magnetron Teer sputtering device with two C targets and a Ti target in Ar atmosphere, on steel and Si substrates. To deposit hydrogenated coatings methane was introduced in the discharge atmosphere. The films were deposited in a range of 7–14 at.% Ti content. X-ray diffraction patterns revealed the presence of a nanocrystalline TiC phase. The hardness varied from 8 to 9 GPa. The tribological tests were performed under dry sliding and lubricated (0.9% NaCl water solution, physiological solution, PS, and 10% fetal bovine serum dissolved in Ringer’s saline solution, FBS) conditions, using a 100Cr6 steel balls with a diameter of 6 mm, in a pin-on-disc wear test apparatus.

This record has no associated files available for download.

More information

Published date: 2011
Organisations: nCATS Group

Identifiers

Local EPrints ID: 199837
URI: http://eprints.soton.ac.uk/id/eprint/199837
ISSN: 0042-207X
PURE UUID: d26f2b68-f55c-4050-a704-d68d2cf7c9e2
ORCID for Tomas Polcar: ORCID iD orcid.org/0000-0002-0863-6287

Catalogue record

Date deposited: 20 Oct 2011 10:34
Last modified: 15 Mar 2024 03:40

Export record

Altmetrics

Contributors

Author: Ana Escudeiro
Author: Tomas Polcar ORCID iD
Author: Albano Cavaleiro

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×