Optimisation of a microfluidic analysis chamber for the placement of microelectrodes

Optimisation of a microfluidic analysis chamber for the placement of microelectrodes
Optimisation of a microfluidic analysis chamber for the placement of microelectrodes
The behaviour of droplets entering a microfluidic chamber designed to house microelectrode detectors for real time analysis of clinical microdialysate is described. We have designed an analysis chamber to collect the droplets produced by multiphase flows of oil and artificial cerebral spinal fluid. The coalescence chamber creates a constant aqueous environment ideal for the placement of microelectrodes avoiding the contamination of the microelectrode surface by oil. A stream of alternating light and dark coloured droplets were filmed as they passed through the chamber using a high speed camera. Image analysis of these videos shows the colour change evolution at each point along the chamber length. The flow in the chamber was simulated using the general solution for Poiseuille flow in a rectangular chamber. It is shown that on the centre line the velocity profile is very close to parabolic, and an expression is presented for the ratio between this centre line velocity and the mean flow velocity as a function of channel aspect ratio. If this aspect ratio of width/height is 2, the ratio of flow velocities closely matches that of Poiseuille flow in a circular tube, with implications for connections between microfluidic channels and connection tubing. The droplets are well mixed as the surface tension at the interface with the oil dominates the viscous forces. However once the droplet coalesces with the solution held in the chamber, the no-slip condition at the walls allows Poiseuille flow to take over. The meniscus at the back of the droplet continues to mix the droplet and acts as a piston until the meniscus stops moving. We have found that the no-slip conditions at the walls of the chamber, create a banding effect which records the history of previous drops. The optimal position for sensors is to be placed at the plane of droplet coalescence ideally at the centre of the channel, where there is an abrupt concentration change leading to a response time ?16 ms, the compressed frame rate of the video. Further away from this point the response time and sensitivity decrease due to convective dispersion.
1463-9076
5298-5303
Rogers, Michelle
ba940cc5-92a3-4aa8-af4b-6be2562dc83a
Leong, Chi
19e5ed05-8ac5-4e92-8ae1-ae1559367174
Niu, Xize
f3d964fb-23b4-45db-92fe-02426e4e76fa
de Mello, Andrew
282cb094-9757-41c0-b73f-75d01d33cd3f
Parker, Kim H.
9e87c3a6-5f17-4681-ba96-2c62f2817fb5
Boutelle, Martyn G.
71e1592c-2e38-4695-8104-b233cc615494
Rogers, Michelle
ba940cc5-92a3-4aa8-af4b-6be2562dc83a
Leong, Chi
19e5ed05-8ac5-4e92-8ae1-ae1559367174
Niu, Xize
f3d964fb-23b4-45db-92fe-02426e4e76fa
de Mello, Andrew
282cb094-9757-41c0-b73f-75d01d33cd3f
Parker, Kim H.
9e87c3a6-5f17-4681-ba96-2c62f2817fb5
Boutelle, Martyn G.
71e1592c-2e38-4695-8104-b233cc615494

Rogers, Michelle, Leong, Chi, Niu, Xize, de Mello, Andrew, Parker, Kim H. and Boutelle, Martyn G. (2011) Optimisation of a microfluidic analysis chamber for the placement of microelectrodes. Physical Chemistry Chemical Physics, 13 (12), 5298-5303. (doi:10.1039/c0cp02810j).

Record type: Article

Abstract

The behaviour of droplets entering a microfluidic chamber designed to house microelectrode detectors for real time analysis of clinical microdialysate is described. We have designed an analysis chamber to collect the droplets produced by multiphase flows of oil and artificial cerebral spinal fluid. The coalescence chamber creates a constant aqueous environment ideal for the placement of microelectrodes avoiding the contamination of the microelectrode surface by oil. A stream of alternating light and dark coloured droplets were filmed as they passed through the chamber using a high speed camera. Image analysis of these videos shows the colour change evolution at each point along the chamber length. The flow in the chamber was simulated using the general solution for Poiseuille flow in a rectangular chamber. It is shown that on the centre line the velocity profile is very close to parabolic, and an expression is presented for the ratio between this centre line velocity and the mean flow velocity as a function of channel aspect ratio. If this aspect ratio of width/height is 2, the ratio of flow velocities closely matches that of Poiseuille flow in a circular tube, with implications for connections between microfluidic channels and connection tubing. The droplets are well mixed as the surface tension at the interface with the oil dominates the viscous forces. However once the droplet coalesces with the solution held in the chamber, the no-slip condition at the walls allows Poiseuille flow to take over. The meniscus at the back of the droplet continues to mix the droplet and acts as a piston until the meniscus stops moving. We have found that the no-slip conditions at the walls of the chamber, create a banding effect which records the history of previous drops. The optimal position for sensors is to be placed at the plane of droplet coalescence ideally at the centre of the channel, where there is an abrupt concentration change leading to a response time ?16 ms, the compressed frame rate of the video. Further away from this point the response time and sensitivity decrease due to convective dispersion.

This record has no associated files available for download.

More information

e-pub ahead of print date: 23 February 2011
Published date: 2011
Organisations: Mechatronics

Identifiers

Local EPrints ID: 199861
URI: http://eprints.soton.ac.uk/id/eprint/199861
ISSN: 1463-9076
PURE UUID: 03295193-f1df-45f9-85bb-1fb413ad4b1c

Catalogue record

Date deposited: 21 Oct 2011 13:49
Last modified: 14 Mar 2024 04:17

Export record

Altmetrics

Contributors

Author: Michelle Rogers
Author: Chi Leong
Author: Xize Niu
Author: Andrew de Mello
Author: Kim H. Parker
Author: Martyn G. Boutelle

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×