Prevention of loosening in total hip replacements using guided bone regeneration
Prevention of loosening in total hip replacements using guided bone regeneration
The aim of this study was to prevent wear debris from reaching the interface of the acetabular cup and femoral component by using a partially occlusive expanded polytetrafluoroethylene membrane. This membrane initially acted as a physical seal, which became incorporated by bone and soft tissue, forming a secondary biologic seal, preventing loosening. An animal model was developed to test the hypothesis. The model replicated the mechanisms of loosening where the effects of wear debris were studied. Using femoral heads with the appropriate roughness, a goat model produced the radiologic and histologic presentation of loosening as observed in total hip replacements in humans. Loosening was assessed by measurement of the radiolucent lines, and was attributed to wear debris by histologic investigation. The expanded polytetrafluoroethylene membrane prevented acetabular implant loosening to a statistical significance of 0.02 in a blinded assessment when compared with the control groups. Loosening of the first 5 mm of the proximomedial aspect of the femur also was prevented. The authors of the current study prevented wear particle-induced osteolysis in the acetabular component by using an expanded polytetrafluoroethylene membrane to seal the bone-cement interface
192-204
Bhumbra, R.P.
20ec47a8-2e97-4d17-a077-ad0873b847f7
Berman, A.B.
836e4833-e384-4ef8-867d-ae64ef0a7def
Walker, P.S.
c56c122e-766d-49c5-81c2-6a4c8b6a8470
Barrett, D.S.
cbaaf354-cc75-42d4-980c-0a8797db5b4c
Blunn, G.W.
637c8cf8-0dc1-4084-92db-e9fdd39f202e
2000
Bhumbra, R.P.
20ec47a8-2e97-4d17-a077-ad0873b847f7
Berman, A.B.
836e4833-e384-4ef8-867d-ae64ef0a7def
Walker, P.S.
c56c122e-766d-49c5-81c2-6a4c8b6a8470
Barrett, D.S.
cbaaf354-cc75-42d4-980c-0a8797db5b4c
Blunn, G.W.
637c8cf8-0dc1-4084-92db-e9fdd39f202e
Bhumbra, R.P., Berman, A.B., Walker, P.S., Barrett, D.S. and Blunn, G.W.
(2000)
Prevention of loosening in total hip replacements using guided bone regeneration.
Clinical Orthopaedics and Related Research, 372, .
Abstract
The aim of this study was to prevent wear debris from reaching the interface of the acetabular cup and femoral component by using a partially occlusive expanded polytetrafluoroethylene membrane. This membrane initially acted as a physical seal, which became incorporated by bone and soft tissue, forming a secondary biologic seal, preventing loosening. An animal model was developed to test the hypothesis. The model replicated the mechanisms of loosening where the effects of wear debris were studied. Using femoral heads with the appropriate roughness, a goat model produced the radiologic and histologic presentation of loosening as observed in total hip replacements in humans. Loosening was assessed by measurement of the radiolucent lines, and was attributed to wear debris by histologic investigation. The expanded polytetrafluoroethylene membrane prevented acetabular implant loosening to a statistical significance of 0.02 in a blinded assessment when compared with the control groups. Loosening of the first 5 mm of the proximomedial aspect of the femur also was prevented. The authors of the current study prevented wear particle-induced osteolysis in the acetabular component by using an expanded polytetrafluoroethylene membrane to seal the bone-cement interface
This record has no associated files available for download.
More information
Published date: 2000
Identifiers
Local EPrints ID: 21397
URI: http://eprints.soton.ac.uk/id/eprint/21397
ISSN: 0009-921X
PURE UUID: cca59b25-549b-4b65-9710-20a6202b3d5b
Catalogue record
Date deposited: 19 Feb 2007
Last modified: 08 Jan 2022 18:51
Export record
Contributors
Author:
R.P. Bhumbra
Author:
A.B. Berman
Author:
P.S. Walker
Author:
G.W. Blunn
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics