Disposable screen-printed biosensor for transcutaneous oxygen measurement
Disposable screen-printed biosensor for transcutaneous oxygen measurement
A disposable transcutaneous oxygen sensor has been designed and fabricated in-house employing screen-printing methods so as to achieve cost-effective and reliable production. The oxygen sensing module of the device is based on the amperometric Clarke cell principle. A three-electrode configuration consisting of miniature gold working and counter-electrodes and a silver/silver chloride reference electrode is screen-printed onto alumina substrate resulting in approximately 15 µm thickness layers. A platinum heater element is integrated into the design to make transcutaneous measurements, typically at 44°C. The performances of different screen-printed membrane materials have been evaluated in both hydrated and dry test conditions using cyclic voltammographs and static tests where the devices are subjected to different oxygen levels. All measurements are made by a fully automated computer-controlled gas rig.
transcutaneous oxygen, screen-printing, amperometric
2074-2081
Lam, Yu-Zhi
2a996163-eec3-478b-8298-002f33cb719f
Atkinson, John
5e9729b2-0e1f-400d-a889-c74f6390ea58
Atkinson, John
5e9729b2-0e1f-400d-a889-c74f6390ea58
2002
Lam, Yu-Zhi
2a996163-eec3-478b-8298-002f33cb719f
Atkinson, John
5e9729b2-0e1f-400d-a889-c74f6390ea58
Atkinson, John
5e9729b2-0e1f-400d-a889-c74f6390ea58
Lam, Yu-Zhi and Atkinson, John
,
Atkinson, John
(ed.)
(2002)
Disposable screen-printed biosensor for transcutaneous oxygen measurement.
Measurement Science and Technology, 13, .
(doi:10.1088/0957-0233/13/12/336).
Abstract
A disposable transcutaneous oxygen sensor has been designed and fabricated in-house employing screen-printing methods so as to achieve cost-effective and reliable production. The oxygen sensing module of the device is based on the amperometric Clarke cell principle. A three-electrode configuration consisting of miniature gold working and counter-electrodes and a silver/silver chloride reference electrode is screen-printed onto alumina substrate resulting in approximately 15 µm thickness layers. A platinum heater element is integrated into the design to make transcutaneous measurements, typically at 44°C. The performances of different screen-printed membrane materials have been evaluated in both hydrated and dry test conditions using cyclic voltammographs and static tests where the devices are subjected to different oxygen levels. All measurements are made by a fully automated computer-controlled gas rig.
This record has no associated files available for download.
More information
Published date: 2002
Keywords:
transcutaneous oxygen, screen-printing, amperometric
Identifiers
Local EPrints ID: 22332
URI: http://eprints.soton.ac.uk/id/eprint/22332
ISSN: 0957-0233
PURE UUID: aecf2912-4e7c-4029-9c0e-ad45b748750d
Catalogue record
Date deposited: 23 Mar 2006
Last modified: 16 Mar 2024 02:32
Export record
Altmetrics
Contributors
Author:
Yu-Zhi Lam
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics