Finite element analysis of the initial stability of ankle arthrodesis with internal fixation: flat cut versus intact joint contours.

Finite element analysis of the initial stability of ankle arthrodesis with internal fixation: flat cut versus intact joint contours.
Finite element analysis of the initial stability of ankle arthrodesis with internal fixation: flat cut versus intact joint contours.
Objective. Qualitative comparison of the initial stability provided by two joint preparation techniques and various screw configurations in ankle arthrodesis, using the finite element method.
Design. A three-dimensional model of a healthy ankle was developed from computed tomography images. Two groups of models were built, one with the joint contours resected to produce flat surfaces, and the second with the joint contours preserved. In each case, a variety of screw orientations were examined.
Background. Despite the improved results of ankle arthrodesis, failure rates due to non-union are still reported. The initial stability of the arthrodesis construct seems important in the final outcome of the fusion.
Methods. Non-linear contact finite element analyses were performed in the arthrodesis constructs subjected to internal/external torsion and dorsiflexion. Micromotions at the bone-to-bone interface were calculated for frictionless and Coulomb friction contact, and compared for the two joint preparation techniques and screw configurations.
Results. Overall lower peak micromotions were predicted when preserving the joint contours both in torsion and dorsiflexion. For both preparation techniques, the lowest micromotions tended to occur with the screws inserted at 30° with respect to the long axis of the tibia, crossing above the fusion site. Inclusion of friction in the models caused a general decrease on the magnitude of the micromotions as compared to the frictionless case, but did not affect the ranking of the models.
Conclusions. The finite element method can be used as a qualitative tool to study the initial stability of ankle arthrodesis, overcoming the difficulties of measuring bone-to-bone interface micromotions experimentally. Better initial stability was predicted for ankle arthrodesis when the joint contours were preserved rather than resected. Crossing the screws above the fusion site at a steeper angle also tended to increase the stability at the fusion site. Relevance
Finite element analyses can help during the pre-operative planning of ankle arthrodesis. When bone density is not compromised, preserving the joint contour and inserting the screws at less than 45° to the long axis of the tibia, crossing over the arthrodesis site, may offer better initial stability.
ankle arthrodesis, internal fixation, crossed screws, surface preparation, finite element, initial stability, micromotion
0268-0033
244-253
Alonso-Vazquez, Ana
02789b60-8832-4252-9e93-94a9613ea57d
Lauge-Pederson, Henrik
9863cc67-d4f1-4dc7-b392-b9fc09277ce9
Lidgren, Lars
21daf4e7-a209-4b38-ba45-2a02a307dc73
Taylor, Mark
e368bda3-6ca5-4178-80e9-41a689badeeb
Alonso-Vazquez, Ana
02789b60-8832-4252-9e93-94a9613ea57d
Lauge-Pederson, Henrik
9863cc67-d4f1-4dc7-b392-b9fc09277ce9
Lidgren, Lars
21daf4e7-a209-4b38-ba45-2a02a307dc73
Taylor, Mark
e368bda3-6ca5-4178-80e9-41a689badeeb

Alonso-Vazquez, Ana, Lauge-Pederson, Henrik, Lidgren, Lars and Taylor, Mark (2003) Finite element analysis of the initial stability of ankle arthrodesis with internal fixation: flat cut versus intact joint contours. Clinical Biomechanics, 18 (3), 244-253. (doi:10.1016/S0268-0033(02)00207-3).

Record type: Article

Abstract

Objective. Qualitative comparison of the initial stability provided by two joint preparation techniques and various screw configurations in ankle arthrodesis, using the finite element method.
Design. A three-dimensional model of a healthy ankle was developed from computed tomography images. Two groups of models were built, one with the joint contours resected to produce flat surfaces, and the second with the joint contours preserved. In each case, a variety of screw orientations were examined.
Background. Despite the improved results of ankle arthrodesis, failure rates due to non-union are still reported. The initial stability of the arthrodesis construct seems important in the final outcome of the fusion.
Methods. Non-linear contact finite element analyses were performed in the arthrodesis constructs subjected to internal/external torsion and dorsiflexion. Micromotions at the bone-to-bone interface were calculated for frictionless and Coulomb friction contact, and compared for the two joint preparation techniques and screw configurations.
Results. Overall lower peak micromotions were predicted when preserving the joint contours both in torsion and dorsiflexion. For both preparation techniques, the lowest micromotions tended to occur with the screws inserted at 30° with respect to the long axis of the tibia, crossing above the fusion site. Inclusion of friction in the models caused a general decrease on the magnitude of the micromotions as compared to the frictionless case, but did not affect the ranking of the models.
Conclusions. The finite element method can be used as a qualitative tool to study the initial stability of ankle arthrodesis, overcoming the difficulties of measuring bone-to-bone interface micromotions experimentally. Better initial stability was predicted for ankle arthrodesis when the joint contours were preserved rather than resected. Crossing the screws above the fusion site at a steeper angle also tended to increase the stability at the fusion site. Relevance
Finite element analyses can help during the pre-operative planning of ankle arthrodesis. When bone density is not compromised, preserving the joint contour and inserting the screws at less than 45° to the long axis of the tibia, crossing over the arthrodesis site, may offer better initial stability.

This record has no associated files available for download.

More information

Published date: 2003
Keywords: ankle arthrodesis, internal fixation, crossed screws, surface preparation, finite element, initial stability, micromotion

Identifiers

Local EPrints ID: 22382
URI: http://eprints.soton.ac.uk/id/eprint/22382
ISSN: 0268-0033
PURE UUID: c2db5e8f-fa12-4580-87aa-f2dac3e81b0c

Catalogue record

Date deposited: 21 Mar 2006
Last modified: 15 Mar 2024 06:37

Export record

Altmetrics

Contributors

Author: Ana Alonso-Vazquez
Author: Henrik Lauge-Pederson
Author: Lars Lidgren
Author: Mark Taylor

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×