A comparison of simultaneous measurements from shipboard VM-150 and OS-75 acoustic Doppler current profilers
A comparison of simultaneous measurements from shipboard VM-150 and OS-75 acoustic Doppler current profilers
This paper compares the performance of two shipmounted
acoustic Doppler current profilers: the well-proven 150 kHz VM-150 instrument and the more recent 75 kHz phased array instrument. On station, mean current profiles over 29-429 m differed by less than 0.2 cm s-' in the east and north components. Mean differences over a 350 km section were
larger when underway at - 5 m s -', but no larger than 2 cm s-'.
On station, 90% of the profiles from the 75 kHz ADCP achieved
a range in excess of 675 m. In calm conditions, the underway
range was also in excess of 675 m. However, the range achieved with the instrument decreased faster with increasing wind speed than for the 150 kHz ADCP. During winds of 15 m s-' the range for both instruments lay between 150-300.a
191-196
Holliday, N.P.
358b0b33-f30b-44fd-a193-88365bbf2c79
Pollard, R.T.
0c78b909-8a95-4bd2-82fd-9b11022888fd
Griffiths, G.
2887c3c7-95f2-4834-b3f6-0284344d3580
2003
Holliday, N.P.
358b0b33-f30b-44fd-a193-88365bbf2c79
Pollard, R.T.
0c78b909-8a95-4bd2-82fd-9b11022888fd
Griffiths, G.
2887c3c7-95f2-4834-b3f6-0284344d3580
Holliday, N.P., Pollard, R.T. and Griffiths, G.
(2003)
A comparison of simultaneous measurements from shipboard VM-150 and OS-75 acoustic Doppler current profilers.
In Proceedings of the IEEE/OES Seventh Working Conference on Current Measurement.
IEEE.
.
Record type:
Conference or Workshop Item
(Paper)
Abstract
This paper compares the performance of two shipmounted
acoustic Doppler current profilers: the well-proven 150 kHz VM-150 instrument and the more recent 75 kHz phased array instrument. On station, mean current profiles over 29-429 m differed by less than 0.2 cm s-' in the east and north components. Mean differences over a 350 km section were
larger when underway at - 5 m s -', but no larger than 2 cm s-'.
On station, 90% of the profiles from the 75 kHz ADCP achieved
a range in excess of 675 m. In calm conditions, the underway
range was also in excess of 675 m. However, the range achieved with the instrument decreased faster with increasing wind speed than for the 150 kHz ADCP. During winds of 15 m s-' the range for both instruments lay between 150-300.a
This record has no associated files available for download.
More information
Published date: 2003
Venue - Dates:
IEEE/OES Seventh Working Conference on Current Measurement Technology, San Diego, USA, 2003-03-13 - 2003-03-15
Identifiers
Local EPrints ID: 22445
URI: http://eprints.soton.ac.uk/id/eprint/22445
PURE UUID: b3c01921-cdbc-44dc-be96-5958b44938cb
Catalogue record
Date deposited: 28 Mar 2006
Last modified: 05 Mar 2024 18:10
Export record
Contributors
Author:
N.P. Holliday
Author:
R.T. Pollard
Author:
G. Griffiths
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.