Configuration and calibration of pickup coils for measurement of ac loss in long superconductors
Configuration and calibration of pickup coils for measurement of ac loss in long superconductors
Pickup coils are widely used for measurements of magnetic susceptibility and hysteretic losses in magnetic and superconducting materials. A general formulation for the calibration of such pickup coils with different geometries is presented. Although the procedure described here is general and can be applied to any coil and sample, special emphasis has been placed on the calibration of saddlelike coils usually used to measure ac losses of long superconductors under ac fields perpendicular to their long dimension.
Numerical simulations and experimental measurements have been carried out in order to determine the geometrical limitations of the pickup coil/sample configurations. This is especially important when simple coils of small dimensions and number of turns are used and/or samples of high demagnetization factor are measured. Superconductors of different geometry, in particular, wires and tapes under parallel and perpendicular fields, have been analyzed.
2141-2149
Yang, Y.
4cac858a-e0c0-4174-a839-05ca394fc51f
Martinez, E.
67ed8d9b-3213-4797-aeae-1c9e6985e48f
Norris, W.T.
44cf1b46-6f4b-4edd-8b07-228cb57f0fa1
2004
Yang, Y.
4cac858a-e0c0-4174-a839-05ca394fc51f
Martinez, E.
67ed8d9b-3213-4797-aeae-1c9e6985e48f
Norris, W.T.
44cf1b46-6f4b-4edd-8b07-228cb57f0fa1
Yang, Y., Martinez, E. and Norris, W.T.
(2004)
Configuration and calibration of pickup coils for measurement of ac loss in long superconductors.
Journal of Applied Physics, 96 (4), .
(doi:10.1063/1.1766100).
Abstract
Pickup coils are widely used for measurements of magnetic susceptibility and hysteretic losses in magnetic and superconducting materials. A general formulation for the calibration of such pickup coils with different geometries is presented. Although the procedure described here is general and can be applied to any coil and sample, special emphasis has been placed on the calibration of saddlelike coils usually used to measure ac losses of long superconductors under ac fields perpendicular to their long dimension.
Numerical simulations and experimental measurements have been carried out in order to determine the geometrical limitations of the pickup coil/sample configurations. This is especially important when simple coils of small dimensions and number of turns are used and/or samples of high demagnetization factor are measured. Superconductors of different geometry, in particular, wires and tapes under parallel and perpendicular fields, have been analyzed.
This record has no associated files available for download.
More information
Published date: 2004
Identifiers
Local EPrints ID: 23642
URI: http://eprints.soton.ac.uk/id/eprint/23642
ISSN: 0021-8979
PURE UUID: 585319f4-2889-42f6-869c-b0a17483ec6d
Catalogue record
Date deposited: 23 Mar 2006
Last modified: 16 Mar 2024 02:44
Export record
Altmetrics
Contributors
Author:
E. Martinez
Author:
W.T. Norris
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics