Evaluation of a model for total body protein mass based on dual-energy X-ray absorptiometry: comparison with a reference four-component model

Evaluation of a model for total body protein mass based on dual-energy X-ray absorptiometry: comparison with a reference four-component model
Evaluation of a model for total body protein mass based on dual-energy X-ray absorptiometry: comparison with a reference four-component model
The aim of the present study was to evaluate a model of body composition for assessing total body protein (TBP) mass using dual-energy X-ray absorptiometry (DXA), with either measured or assumed total body water (TBW); it was intended to provide a less complex or demanding alternative technique to, for example, the four-component model (4-CM). The following measurements were obtained in healthy adults (n 46) aged 18–62 years, and children (n 30) aged 8–12 years: body weight (BWt), body volume (BV; under-water weighing), TBW (2H-dilution space or predicted using an assumed hydration fraction of fat-free mass (HFffm)), bone mineral content (BMC; DXA) and fat-free soft tissue (FFST; DXA). TBP was calculated using the 4-CM (TBP=3·050BWt-0·290TBW-2·734BMC-2·747BV) and the DXA model (TBP=FFST-0·2305BMC-TBW). DXA measurements were obtained using the Lunar DPX (Lunar Radiation Corporation, Madison, WI, USA) or Hologic QDR 1000/W (Hologic, Waltham, MA, USA). Precision of the DXA model for TBP with measured TBW (4·6–6·8 % mean TBP) was slightly worse than the 4-CM (4·0–5·4 %), whereas that modelled with assumed HFffm was more precise (2·4–5·2 %) because it obviated imprecision associated with measuring TBW. Agreement between the 4-CM and DXA model with measured TBW was also worse (e.g. bias, 15 % of the mean; 95 % limits of agreement up to ±39 % for adults measured on the Lunar DPX) than when a constant for HFffm was assumed (3·7 % and ±21 % respectively). Most of the variability in agreement between these various models was due to interpretation of biological factors, rather than to measurement imprecision. Therefore, the DXA model, which is less complex and demanding than the 4-CM, is of value for assessing TBP in groups of healthy subjects, but is of less value for individuals in whom there may be substantial differences from reference 4-CM estimates.
body composition, bone mineral, fat-free mass, total body water
0007-1145
45-52
Fuller, N.J.
e3e40db8-e5eb-45d9-aacb-d032efa14daf
Wells, J.C.K.
fb8f5f68-3f96-46d9-8314-c4a41e796085
Elia, M.
964bf436-e623-46d6-bc3f-5dd04c9ef4c1
Fuller, N.J.
e3e40db8-e5eb-45d9-aacb-d032efa14daf
Wells, J.C.K.
fb8f5f68-3f96-46d9-8314-c4a41e796085
Elia, M.
964bf436-e623-46d6-bc3f-5dd04c9ef4c1

Fuller, N.J., Wells, J.C.K. and Elia, M. (2001) Evaluation of a model for total body protein mass based on dual-energy X-ray absorptiometry: comparison with a reference four-component model. British Journal of Nutrition, 86 (1), 45-52. (doi:10.1079/BJN2001387).

Record type: Article

Abstract

The aim of the present study was to evaluate a model of body composition for assessing total body protein (TBP) mass using dual-energy X-ray absorptiometry (DXA), with either measured or assumed total body water (TBW); it was intended to provide a less complex or demanding alternative technique to, for example, the four-component model (4-CM). The following measurements were obtained in healthy adults (n 46) aged 18–62 years, and children (n 30) aged 8–12 years: body weight (BWt), body volume (BV; under-water weighing), TBW (2H-dilution space or predicted using an assumed hydration fraction of fat-free mass (HFffm)), bone mineral content (BMC; DXA) and fat-free soft tissue (FFST; DXA). TBP was calculated using the 4-CM (TBP=3·050BWt-0·290TBW-2·734BMC-2·747BV) and the DXA model (TBP=FFST-0·2305BMC-TBW). DXA measurements were obtained using the Lunar DPX (Lunar Radiation Corporation, Madison, WI, USA) or Hologic QDR 1000/W (Hologic, Waltham, MA, USA). Precision of the DXA model for TBP with measured TBW (4·6–6·8 % mean TBP) was slightly worse than the 4-CM (4·0–5·4 %), whereas that modelled with assumed HFffm was more precise (2·4–5·2 %) because it obviated imprecision associated with measuring TBW. Agreement between the 4-CM and DXA model with measured TBW was also worse (e.g. bias, 15 % of the mean; 95 % limits of agreement up to ±39 % for adults measured on the Lunar DPX) than when a constant for HFffm was assumed (3·7 % and ±21 % respectively). Most of the variability in agreement between these various models was due to interpretation of biological factors, rather than to measurement imprecision. Therefore, the DXA model, which is less complex and demanding than the 4-CM, is of value for assessing TBP in groups of healthy subjects, but is of less value for individuals in whom there may be substantial differences from reference 4-CM estimates.

This record has no associated files available for download.

More information

Published date: 2001
Keywords: body composition, bone mineral, fat-free mass, total body water

Identifiers

Local EPrints ID: 25507
URI: http://eprints.soton.ac.uk/id/eprint/25507
ISSN: 0007-1145
PURE UUID: e88ae1cc-f9f1-49ab-ac7d-0e850aa772e7

Catalogue record

Date deposited: 19 Apr 2006
Last modified: 15 Mar 2024 07:03

Export record

Altmetrics

Contributors

Author: N.J. Fuller
Author: J.C.K. Wells
Author: M. Elia

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×