The University of Southampton
University of Southampton Institutional Repository

Effect of the length of degassing period on the space charge dynamic in XLPE insulation under DC stressing condition

Effect of the length of degassing period on the space charge dynamic in XLPE insulation under DC stressing condition
Effect of the length of degassing period on the space charge dynamic in XLPE insulation under DC stressing condition
In this paper, the space charge measurement results obtained from planar samples of XLPE (made by Borealis XL4201S) over a 24 hours Dc ageing are reported. Some preliminary results on the effect of the sample degassing period on space charge distribution in the XLPE material are discussed, and comparative study between as-received and degassed XLPE samples with different length of degassing period (degassed for 6, 12, 24 and 48 hours at 60OC) are also be presented.
Space charge, XLPE, degassing teratment, interfacial stress
7-900371-56-7
160-163
Ho, Y. F. F.
9d4605db-8b38-4c4d-8d9f-3db7f235a335
Chong, Y. L.
d56e3702-5941-486a-ba8c-2f4675c82e96
Chen, G
3de45a9c-6c9a-4bcb-90c3-d7e26be21819
Ho, Y. F. F.
9d4605db-8b38-4c4d-8d9f-3db7f235a335
Chong, Y. L.
d56e3702-5941-486a-ba8c-2f4675c82e96
Chen, G
3de45a9c-6c9a-4bcb-90c3-d7e26be21819

Ho, Y. F. F., Chong, Y. L. and Chen, G (2003) Effect of the length of degassing period on the space charge dynamic in XLPE insulation under DC stressing condition. The 2nd International Conference on Insulation Condition Mornitoring of Electrical Plant, Chongqing, China. 27 - 30 Oct 2003. pp. 160-163 .

Record type: Conference or Workshop Item (Other)

Abstract

In this paper, the space charge measurement results obtained from planar samples of XLPE (made by Borealis XL4201S) over a 24 hours Dc ageing are reported. Some preliminary results on the effect of the sample degassing period on space charge distribution in the XLPE material are discussed, and comparative study between as-received and degassed XLPE samples with different length of degassing period (degassed for 6, 12, 24 and 48 hours at 60OC) are also be presented.

This record has no associated files available for download.

More information

Published date: 2003
Additional Information: Event Dates: October 27-30, 2003
Venue - Dates: The 2nd International Conference on Insulation Condition Mornitoring of Electrical Plant, Chongqing, China, 2003-10-27 - 2003-10-30
Keywords: Space charge, XLPE, degassing teratment, interfacial stress
Organisations: Electronics & Computer Science, EEE

Identifiers

Local EPrints ID: 258520
URI: http://eprints.soton.ac.uk/id/eprint/258520
ISBN: 7-900371-56-7
PURE UUID: 55839263-030c-4e5b-b6d3-349765010243

Catalogue record

Date deposited: 10 Nov 2003
Last modified: 10 Dec 2021 20:56

Export record

Contributors

Author: Y. F. F. Ho
Author: Y. L. Chong
Author: G Chen

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×