The University of Southampton
University of Southampton Institutional Repository

Examination of a middle cardiac vein defibrillation coil as stand-alone anode, auxiliary anode, and bystander electrode in a transvenous defibrillation circuit

Examination of a middle cardiac vein defibrillation coil as stand-alone anode, auxiliary anode, and bystander electrode in a transvenous defibrillation circuit
Examination of a middle cardiac vein defibrillation coil as stand-alone anode, auxiliary anode, and bystander electrode in a transvenous defibrillation circuit
In porcine studies anodes in the middle cardiac vein compare favorably with those in the RV. It has not been demonstrated whether the RV and middle cardiac vein or the middle cardiac vein alone anodes are superior when shocking to a conventional SVC and active housing cathode nor whether a bystander middle cardiac vein electrode exerts a passive electrode affect. Twelve pigs were anesthetized and had an active housing implanted in the left pectoral region and defibrillation coils placed at the RV apex and in the SVC. A custom-made defibrillation coil (Ela Medical) was advanced into the middle cardiac vein through a 9 Fr transvenous catheter. The DFT for three anodes (RV; RV and middle cardiac vein; middle cardiac vein) to the SVC and active housing was then assessed by a three reversal binary search, the order of testing was randomized. In seven animals DFT was assessed in the same way for the configuration of RV to SVC and active housing twice more, with and without a bystander middle cardiac vein coil electrode in place. The results were middle cardiac vein 7.5 ± 1.7 J, RV and middle cardiac vein 7.3 ± 1.7 J reduced DFT significantly compared to RV 13.8 ± 4.2 J (both P < 0.000). There was no significant difference between the middle cardiac vein and the middle cardiac vein and RV (P = 0.67, 95% CI for difference ? 0.64–0.96). The DFT of RV to SVC and the active housing was the same with (13.2 ± 4.0) and without (13.7 ± 4.2) the middle cardiac vein bystander coil in place (P = 0.177, 95% CI for difference ? 0.33–1.33 J). Shocking to a SVC and active housing cathode, middle cardiac vein, and RV and middle cardiac vein anodes are equally effective in lowering DFT compared to the RV. The middle cardiac vein coil electrode does not exert a passive electrode affect on the RV to the SVC and active housing defibrillation.
1089-1093
Paisey, John R.
4d958db6-f32d-4ce7-bef5-003a4a358312
Yue, Arthur M.
4040f8ec-0252-49e0-b838-58f37956acd2
Bessoule, Frederick
1fef63a6-504a-4e23-8191-c7302b803208
Allen, Stuart
e8d968db-4cbc-4c0a-9ad7-775e4134f3df
Roberts, Paul R.
193431e8-f9d5-48d6-8f62-ed9052b2571d
Morgan, John M.
ac98099e-241d-4551-bc98-709f6dfc8680
Paisey, John R.
4d958db6-f32d-4ce7-bef5-003a4a358312
Yue, Arthur M.
4040f8ec-0252-49e0-b838-58f37956acd2
Bessoule, Frederick
1fef63a6-504a-4e23-8191-c7302b803208
Allen, Stuart
e8d968db-4cbc-4c0a-9ad7-775e4134f3df
Roberts, Paul R.
193431e8-f9d5-48d6-8f62-ed9052b2571d
Morgan, John M.
ac98099e-241d-4551-bc98-709f6dfc8680

Paisey, John R., Yue, Arthur M., Bessoule, Frederick, Allen, Stuart, Roberts, Paul R. and Morgan, John M. (2004) Examination of a middle cardiac vein defibrillation coil as stand-alone anode, auxiliary anode, and bystander electrode in a transvenous defibrillation circuit. Pacing and Clinical Electrophysiology, 27 (8), 1089-1093. (doi:10.1111/j.1540-8159.2004.00589.x).

Record type: Article

Abstract

In porcine studies anodes in the middle cardiac vein compare favorably with those in the RV. It has not been demonstrated whether the RV and middle cardiac vein or the middle cardiac vein alone anodes are superior when shocking to a conventional SVC and active housing cathode nor whether a bystander middle cardiac vein electrode exerts a passive electrode affect. Twelve pigs were anesthetized and had an active housing implanted in the left pectoral region and defibrillation coils placed at the RV apex and in the SVC. A custom-made defibrillation coil (Ela Medical) was advanced into the middle cardiac vein through a 9 Fr transvenous catheter. The DFT for three anodes (RV; RV and middle cardiac vein; middle cardiac vein) to the SVC and active housing was then assessed by a three reversal binary search, the order of testing was randomized. In seven animals DFT was assessed in the same way for the configuration of RV to SVC and active housing twice more, with and without a bystander middle cardiac vein coil electrode in place. The results were middle cardiac vein 7.5 ± 1.7 J, RV and middle cardiac vein 7.3 ± 1.7 J reduced DFT significantly compared to RV 13.8 ± 4.2 J (both P < 0.000). There was no significant difference between the middle cardiac vein and the middle cardiac vein and RV (P = 0.67, 95% CI for difference ? 0.64–0.96). The DFT of RV to SVC and the active housing was the same with (13.2 ± 4.0) and without (13.7 ± 4.2) the middle cardiac vein bystander coil in place (P = 0.177, 95% CI for difference ? 0.33–1.33 J). Shocking to a SVC and active housing cathode, middle cardiac vein, and RV and middle cardiac vein anodes are equally effective in lowering DFT compared to the RV. The middle cardiac vein coil electrode does not exert a passive electrode affect on the RV to the SVC and active housing defibrillation.

This record has no associated files available for download.

More information

Published date: 2004

Identifiers

Local EPrints ID: 25872
URI: http://eprints.soton.ac.uk/id/eprint/25872
PURE UUID: c1c95458-0cdc-4bac-b04b-9df4c7f24bf8

Catalogue record

Date deposited: 20 Apr 2006
Last modified: 15 Mar 2024 07:06

Export record

Altmetrics

Contributors

Author: John R. Paisey
Author: Arthur M. Yue
Author: Frederick Bessoule
Author: Stuart Allen
Author: Paul R. Roberts
Author: John M. Morgan

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×