A proposed novel multiplexed near field terahertz microscope
A proposed novel multiplexed near field terahertz microscope
There is burgeoning interest in the possibility that ‘terahertz’ measurements will yield novel biological information. This relates primarily to the fact that proteins and other large molecules have many low frequency modes which fall in the terahertz region and which may give structural information. Additionally there is interest in possible measurements of ‘mechanical’ resonance modes of membranes in structures such as liposomes. A fundamental problem with terahertz measurements is that, since one terahertz has a wavelength of three hundred microns, diffraction limited imaging can only yield a resolution of the order of half a millimetre, too large for items of biological interest. The solution is well known – scanning near field microscopy – which can yield resolution far below the wavelength. However the solution comes with a problem, namely very slow data rates and hence very long imaging times. We describe a proposed multiplexed near field microscope which can collect fully spectrally resolved information on up to ~100 pixels simultaneously using one high quality detector. Resolution of a few microns appears feasible (possibly rather better at the top end of the terahertz range.) The microscope is ideally suited for use with coherently enhanced synchrotron radiation sources provided they run in CW mode.
Rutt, H.N.
e09fa327-0c01-467a-9898-4e7f0cd715fc
Al-Hakim, M.M.
ffb17a24-53fb-465e-8856-1f04b65e6f44
February 2006
Rutt, H.N.
e09fa327-0c01-467a-9898-4e7f0cd715fc
Al-Hakim, M.M.
ffb17a24-53fb-465e-8856-1f04b65e6f44
Rutt, H.N. and Al-Hakim, M.M.
(2006)
A proposed novel multiplexed near field terahertz microscope.
Workshop on Terahertz Radiation, Novosobirsk.
03 - 06 Feb 2006.
Record type:
Conference or Workshop Item
(Other)
Abstract
There is burgeoning interest in the possibility that ‘terahertz’ measurements will yield novel biological information. This relates primarily to the fact that proteins and other large molecules have many low frequency modes which fall in the terahertz region and which may give structural information. Additionally there is interest in possible measurements of ‘mechanical’ resonance modes of membranes in structures such as liposomes. A fundamental problem with terahertz measurements is that, since one terahertz has a wavelength of three hundred microns, diffraction limited imaging can only yield a resolution of the order of half a millimetre, too large for items of biological interest. The solution is well known – scanning near field microscopy – which can yield resolution far below the wavelength. However the solution comes with a problem, namely very slow data rates and hence very long imaging times. We describe a proposed multiplexed near field microscope which can collect fully spectrally resolved information on up to ~100 pixels simultaneously using one high quality detector. Resolution of a few microns appears feasible (possibly rather better at the top end of the terahertz range.) The microscope is ideally suited for use with coherently enhanced synchrotron radiation sources provided they run in CW mode.
Text
ABSTRACT-A_proposed_novel_multiplexed_near_field_Terahertz_microscope.doc
- Author's Original
More information
Published date: February 2006
Additional Information:
Event Dates: 3-6 February 2006
Venue - Dates:
Workshop on Terahertz Radiation, Novosobirsk, 2006-02-03 - 2006-02-06
Organisations:
Optoelectronics Research Centre, Electronics & Computer Science
Identifiers
Local EPrints ID: 264179
URI: http://eprints.soton.ac.uk/id/eprint/264179
PURE UUID: 963dfa3e-900c-4fe9-8753-ffa86fca2965
Catalogue record
Date deposited: 12 Jun 2007
Last modified: 14 Mar 2024 07:43
Export record
Contributors
Author:
H.N. Rutt
Author:
M.M. Al-Hakim
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics