Partial Discharge Source Characterization within a HV Cable Joint
Partial Discharge Source Characterization within a HV Cable Joint
A parameter for partial discharge (PD) source location within a joint bay of a three phase cross-bonded high voltage cable circuit has been assessed. Locally placed sensors can detect PD pulses that propagate within the fault related phase. However, when a cable joint bay is cross-bonded then PD signals from one phase may be measured by sensors on the other two phases as well. Current research at Southampton is considering the practical application of on-line PD monitoring techniques to three phase high voltage cable joints. A simple model, using 66kV cable sections to represent a cross-bonded circuit has been implemented. The model uses one capacitive coupler per phase. Measurement data was obtained by injecting pulses into the core conductor. Data was analysed using a clustering technique in order to determine the PD source location.
1-4244-0750-8
577-580
Hao, L
e6006548-3fc1-4a7e-9df4-a4e9a9a05c45
Lewin, P L
78b4fc49-1cb3-4db9-ba90-3ae70c0f639e
Dodd, S J
13f7eab0-eb74-4e89-83c6-555480aba185
2007
Hao, L
e6006548-3fc1-4a7e-9df4-a4e9a9a05c45
Lewin, P L
78b4fc49-1cb3-4db9-ba90-3ae70c0f639e
Dodd, S J
13f7eab0-eb74-4e89-83c6-555480aba185
Hao, L, Lewin, P L and Dodd, S J
(2007)
Partial Discharge Source Characterization within a HV Cable Joint.
9th IEEE International Conference on Solid Dielectrics, Winchester, Winchester, United Kingdom.
08 - 13 Jul 2007.
.
Record type:
Conference or Workshop Item
(Paper)
Abstract
A parameter for partial discharge (PD) source location within a joint bay of a three phase cross-bonded high voltage cable circuit has been assessed. Locally placed sensors can detect PD pulses that propagate within the fault related phase. However, when a cable joint bay is cross-bonded then PD signals from one phase may be measured by sensors on the other two phases as well. Current research at Southampton is considering the practical application of on-line PD monitoring techniques to three phase high voltage cable joints. A simple model, using 66kV cable sections to represent a cross-bonded circuit has been implemented. The model uses one capacitive coupler per phase. Measurement data was obtained by injecting pulses into the core conductor. Data was analysed using a clustering technique in order to determine the PD source location.
More information
Published date: 2007
Additional Information:
Event Dates: 8 - 13 July 2007
Venue - Dates:
9th IEEE International Conference on Solid Dielectrics, Winchester, Winchester, United Kingdom, 2007-07-08 - 2007-07-13
Organisations:
Electronics & Computer Science, EEE
Identifiers
Local EPrints ID: 264257
URI: http://eprints.soton.ac.uk/id/eprint/264257
ISBN: 1-4244-0750-8
PURE UUID: 9be7ca18-31c0-42c0-81ee-ddd6b5c7ddcb
Catalogue record
Date deposited: 04 Jul 2007
Last modified: 15 Mar 2024 02:43
Export record
Contributors
Author:
L Hao
Author:
P L Lewin
Author:
S J Dodd
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics