Condition Monitoring of Power Cables
Condition Monitoring of Power Cables
A National Grid funded research project at Southampton has investigated possible methodologies for data acquisition, transmission and processing that will facilitate on-line continuous monitoring of partial discharges in high voltage polymeric cable systems. A method that only uses passive components at the measuring points has been developed and is outlined in this paper. More recent work, funded through the EPSRC Supergen V, UK Energy Infrastructure (AMPerES) grant in collaboration with UK electricity network operators has concentrated on the development of partial discharge data processing techniques that ultimately may allow continuous assessment of transmission asset health to be reliably determined.
978-0-86341-796-2
CD-ROM
Lewin, P L
78b4fc49-1cb3-4db9-ba90-3ae70c0f639e
Hao, L
e6006548-3fc1-4a7e-9df4-a4e9a9a05c45
Swaffield, D J
31f6f52e-fb48-44f9-99d3-3cbd2539f1b9
Swingler, S G
4f13fbb2-7d2e-480a-8687-acea6a4ed735
2007
Lewin, P L
78b4fc49-1cb3-4db9-ba90-3ae70c0f639e
Hao, L
e6006548-3fc1-4a7e-9df4-a4e9a9a05c45
Swaffield, D J
31f6f52e-fb48-44f9-99d3-3cbd2539f1b9
Swingler, S G
4f13fbb2-7d2e-480a-8687-acea6a4ed735
Lewin, P L, Hao, L, Swaffield, D J and Swingler, S G
(2007)
Condition Monitoring of Power Cables.
IET Power Convention 2007, London, United Kingdom.
10 - 11 Sep 2007.
.
Record type:
Conference or Workshop Item
(Paper)
Abstract
A National Grid funded research project at Southampton has investigated possible methodologies for data acquisition, transmission and processing that will facilitate on-line continuous monitoring of partial discharges in high voltage polymeric cable systems. A method that only uses passive components at the measuring points has been developed and is outlined in this paper. More recent work, funded through the EPSRC Supergen V, UK Energy Infrastructure (AMPerES) grant in collaboration with UK electricity network operators has concentrated on the development of partial discharge data processing techniques that ultimately may allow continuous assessment of transmission asset health to be reliably determined.
Text
Power_Convention_Paper.pdf
- Other
More information
Published date: 2007
Additional Information:
Event Dates: 10-11 September 2007
Venue - Dates:
IET Power Convention 2007, London, United Kingdom, 2007-09-10 - 2007-09-11
Organisations:
Electronics & Computer Science, EEE
Identifiers
Local EPrints ID: 264486
URI: http://eprints.soton.ac.uk/id/eprint/264486
ISBN: 978-0-86341-796-2
PURE UUID: ba7a1d29-3bbe-4d02-a623-b64105fe28eb
Catalogue record
Date deposited: 11 Sep 2007
Last modified: 15 Mar 2024 02:43
Export record
Contributors
Author:
P L Lewin
Author:
L Hao
Author:
D J Swaffield
Author:
S G Swingler
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics