Partial Discharge Simulation for a High Voltage Transformer Winding using a Model based on Geometrical Dimensions
Partial Discharge Simulation for a High Voltage Transformer Winding using a Model based on Geometrical Dimensions
In high voltage plant, ageing processes can occur in the dielectric and insulation system which are totally unavoidable and ultimately limit the operational life of the plant. For example, these unwanted processes can cause partial discharge (PD) activity inside a transformer and the presence of this activity will lead to further ageing and degradation processes until eventually there is catastrophic failure. Therefore, partial discharge condition monitoring inside a transformer and along a transformer winding has become an important research area to provide asset health information enabling the maintenance and replacement processes to be carried out effectively. There are various methods and models which have been proposed and discussed thoroughly in the literature in order to study PD activity in transformer windings and particularly for location of the PD source. This paper investigates PD signal propagation inside a transformer winding using a transformer winding model based on a lumped parameter network approach. The simulation model represents an interleaved disc type winding which consists of eight sections having internal winding series resistances (R), inductances (L), series and shunt capacitances (K,C), including the effect of their mutual inductances as shown in Figure 1. These parameters are derived using analytical calculations from the geometrical dimensions and the winding simulated using a circuit simulation package (PSPICE OrCAD). The simulation results are captured via both ends of the winding at terminal 1 and terminal 8 which are grounded through a small capacitive and resistive element to represent the bushing end and neutral to earth connection respectively.
36
Abd Rahman, M S
8217f865-63cf-4fa4-9f2b-19589bbdb2f0
Hao, L
e6006548-3fc1-4a7e-9df4-a4e9a9a05c45
Rapisarda, P
79efc3b0-a7c6-4ca7-a7f8-de5770a4281b
Lewin, P L
78b4fc49-1cb3-4db9-ba90-3ae70c0f639e
18 January 2012
Abd Rahman, M S
8217f865-63cf-4fa4-9f2b-19589bbdb2f0
Hao, L
e6006548-3fc1-4a7e-9df4-a4e9a9a05c45
Rapisarda, P
79efc3b0-a7c6-4ca7-a7f8-de5770a4281b
Lewin, P L
78b4fc49-1cb3-4db9-ba90-3ae70c0f639e
Abd Rahman, M S, Hao, L, Rapisarda, P and Lewin, P L
(2012)
Partial Discharge Simulation for a High Voltage Transformer Winding using a Model based on Geometrical Dimensions.
The Fifth UHVnet Colloquium, University of Leicester, Leicester, United Kingdom.
18 - 19 Jan 2012.
.
Record type:
Conference or Workshop Item
(Paper)
Abstract
In high voltage plant, ageing processes can occur in the dielectric and insulation system which are totally unavoidable and ultimately limit the operational life of the plant. For example, these unwanted processes can cause partial discharge (PD) activity inside a transformer and the presence of this activity will lead to further ageing and degradation processes until eventually there is catastrophic failure. Therefore, partial discharge condition monitoring inside a transformer and along a transformer winding has become an important research area to provide asset health information enabling the maintenance and replacement processes to be carried out effectively. There are various methods and models which have been proposed and discussed thoroughly in the literature in order to study PD activity in transformer windings and particularly for location of the PD source. This paper investigates PD signal propagation inside a transformer winding using a transformer winding model based on a lumped parameter network approach. The simulation model represents an interleaved disc type winding which consists of eight sections having internal winding series resistances (R), inductances (L), series and shunt capacitances (K,C), including the effect of their mutual inductances as shown in Figure 1. These parameters are derived using analytical calculations from the geometrical dimensions and the winding simulated using a circuit simulation package (PSPICE OrCAD). The simulation results are captured via both ends of the winding at terminal 1 and terminal 8 which are grounded through a small capacitive and resistive element to represent the bushing end and neutral to earth connection respectively.
Text
SafwanPoster.pdf
- Other
Text
M.S. Abd Rahman_University_Southampton_UHVnet2012-abstract.pdf
- Version of Record
More information
Published date: 18 January 2012
Additional Information:
Event Dates: 18-19 January 2012
Venue - Dates:
The Fifth UHVnet Colloquium, University of Leicester, Leicester, United Kingdom, 2012-01-18 - 2012-01-19
Organisations:
Electronics & Computer Science, EEE, Southampton Wireless Group
Identifiers
Local EPrints ID: 273132
URI: http://eprints.soton.ac.uk/id/eprint/273132
PURE UUID: 5099c676-4435-42bd-acf8-418caac102fd
Catalogue record
Date deposited: 20 Jan 2012 16:58
Last modified: 15 Mar 2024 02:43
Export record
Contributors
Author:
M S Abd Rahman
Author:
L Hao
Author:
P Rapisarda
Author:
P L Lewin
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics