Bilateral cochlear implants aim to improve sound localization compared to monaural implants, among other potential benefits. Monaural cochlear implants should not support localization in the horizontal plane as there are no interaural level and time difference cues available, although some previous studies have suggested limited capability. As background to other studies of bilateral implantation, the localization abilities of 18 monaural cochlear implantees were investigated experimentally in an anechoic chamber, using various sound stimuli with different amounts of temporal information. The effects of head movement and reverberation were also investigated. Localization performance was found to be close to chance for all stimuli. It is confirmed that monaural cochlear implants are unable to support useful auditory sound localization, even when head movements are allowed.
unilateral, cochlear implants, localization
96-104
Buhagiar, R.
47071599-9054-4fe3-9d9e-93bb1bfd73a3
Lutman, M.E.
add34340-3241-4346-a668-8f51fdea6692
Brinton, J.C.
67c91309-96da-4e0b-88b5-cfe556624905
Eyles, J.E.
183486b3-50e3-4dc2-a4cb-ab04023cb83e
2004
Buhagiar, R.
47071599-9054-4fe3-9d9e-93bb1bfd73a3
Lutman, M.E.
add34340-3241-4346-a668-8f51fdea6692
Brinton, J.C.
67c91309-96da-4e0b-88b5-cfe556624905
Eyles, J.E.
183486b3-50e3-4dc2-a4cb-ab04023cb83e
Buhagiar, R., Lutman, M.E., Brinton, J.C. and Eyles, J.E.
(2004)
Localization performance of unilateral cochlear implant users for speech, tones and noise.
Cochlear Implants International, 5 (3), .
Abstract
Bilateral cochlear implants aim to improve sound localization compared to monaural implants, among other potential benefits. Monaural cochlear implants should not support localization in the horizontal plane as there are no interaural level and time difference cues available, although some previous studies have suggested limited capability. As background to other studies of bilateral implantation, the localization abilities of 18 monaural cochlear implantees were investigated experimentally in an anechoic chamber, using various sound stimuli with different amounts of temporal information. The effects of head movement and reverberation were also investigated. Localization performance was found to be close to chance for all stimuli. It is confirmed that monaural cochlear implants are unable to support useful auditory sound localization, even when head movements are allowed.
This record has no associated files available for download.
More information
Published date: 2004
Keywords:
unilateral, cochlear implants, localization
Organisations:
Human Sciences Group
Identifiers
Local EPrints ID: 28235
URI: http://eprints.soton.ac.uk/id/eprint/28235
ISSN: 1467-0100
PURE UUID: 73fffeb7-bfaf-4981-88a8-54104d521181
Catalogue record
Date deposited: 02 May 2006
Last modified: 08 Jan 2022 06:51
Export record
Contributors
Author:
R. Buhagiar
Author:
M.E. Lutman
Author:
J.C. Brinton
Author:
J.E. Eyles
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics