Leaks from buried water distribution pipes are commonly located by applying the correlation technique to two measured acoustic/vibration signals on either side of a leak. The effectiveness of the correlation technique for locating leaks in plastic pipes depends on the type of sensors used and their sensitivities. Based on an analytical model of the cross-correlation of pressure responses established in an earlier study, this paper investigates the behaviour of the cross-correlation coefficient for leak signals measured using pressure, velocity and acceleration sensors. Theoretical predictions show that a measure of pressure responses using hydrophones is effective for measurements where there is a small signal-to-noise ratio (SNR), but a sharper peak correlation coefficient can be achieved if accelerometers are used. The theoretical work is validated to some extent with test data from actual water pipes on a test site in Canada.
927-941
Gao, Y.
3f048356-567d-4308-853f-d98fabfcb6fb
Brennan, M.J.
87c7bca3-a9e5-46aa-9153-34c712355a13
Joseph, P.F.
9c30491e-8464-4c9a-8723-2abc62bdf75d
Muggleton, J.M.
2298700d-8ec7-4241-828a-1a1c5c36ecb5
Hunaidi, O.
4ac03977-e6eb-4154-9bcd-36aec7a19dd3
2005
Gao, Y.
3f048356-567d-4308-853f-d98fabfcb6fb
Brennan, M.J.
87c7bca3-a9e5-46aa-9153-34c712355a13
Joseph, P.F.
9c30491e-8464-4c9a-8723-2abc62bdf75d
Muggleton, J.M.
2298700d-8ec7-4241-828a-1a1c5c36ecb5
Hunaidi, O.
4ac03977-e6eb-4154-9bcd-36aec7a19dd3
Gao, Y., Brennan, M.J., Joseph, P.F., Muggleton, J.M. and Hunaidi, O.
(2005)
On the selection of acoustic/vibration sensors for leak detection in plastic water pipes.
Journal of Sound and Vibration, 283 (3-5), .
(doi:10.1016/j.jsv.2004.05.004).
Abstract
Leaks from buried water distribution pipes are commonly located by applying the correlation technique to two measured acoustic/vibration signals on either side of a leak. The effectiveness of the correlation technique for locating leaks in plastic pipes depends on the type of sensors used and their sensitivities. Based on an analytical model of the cross-correlation of pressure responses established in an earlier study, this paper investigates the behaviour of the cross-correlation coefficient for leak signals measured using pressure, velocity and acceleration sensors. Theoretical predictions show that a measure of pressure responses using hydrophones is effective for measurements where there is a small signal-to-noise ratio (SNR), but a sharper peak correlation coefficient can be achieved if accelerometers are used. The theoretical work is validated to some extent with test data from actual water pipes on a test site in Canada.
This record has no associated files available for download.
More information
Published date: 2005
Identifiers
Local EPrints ID: 28431
URI: http://eprints.soton.ac.uk/id/eprint/28431
ISSN: 0022-460X
PURE UUID: 068da00e-d980-4f86-947b-2a68f67642eb
Catalogue record
Date deposited: 28 Apr 2006
Last modified: 15 Mar 2024 07:24
Export record
Altmetrics
Contributors
Author:
Y. Gao
Author:
M.J. Brennan
Author:
O. Hunaidi
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics