The University of Southampton
University of Southampton Institutional Repository

Tissue differentiation around a short stemmed metaphyseal loading implant employing a modified mechanoregulatory algorithm: a finite element study

Tissue differentiation around a short stemmed metaphyseal loading implant employing a modified mechanoregulatory algorithm: a finite element study
Tissue differentiation around a short stemmed metaphyseal loading implant employing a modified mechanoregulatory algorithm: a finite element study
Short stemmed cementless implants are being used increasingly to avoid problems associated with their long stemmed counterparts such as size, stiffness, and bulky nature, which can contribute to stress shielding, fractures, and hence loosening. They are also thought to enhance physiological loading of the femur. We performed a computational investigation of the possible tissue differentiation and bone ingrowth processes for a specific type of stemless implant using a mechanoregulatory hypothesis, with modifications to simulate tissue differentiation, and simplified loading conditions. The peak forces during stair climbing and normal walking were investigated to evaluate their influence on the process. The results were compared to clinical studies for relevance and corroboration. The majority of the tissue type formed was fibrous, occupying the proximal regions of the implant. The lateral flare design feature of the implant was predicted to enhance bone and cartilage formation in regions beneath it compared to the same design without a flare. The percentage of bone formed increased through the iterations and accounted for nearly 35% of the tissue at the end of the iterations in Gruen zones 2 and 6, replacing cartilage tissue as differentiation progressed. This agreed well with clinical data showing similar regions of bone formation and suggests that the distal regions of the implant under the lateral flare, resting in the metaphyseal region of the bone, promoted implant stability.
0736-0266
787-794
Puthumanapully, Pramod Kumar
6edb8728-cf49-42e5-bf25-dad310ddbc17
Browne, Martin
6578cc37-7bd6-43b9-ae5c-77ccb7726397
Puthumanapully, Pramod Kumar
6edb8728-cf49-42e5-bf25-dad310ddbc17
Browne, Martin
6578cc37-7bd6-43b9-ae5c-77ccb7726397

Puthumanapully, Pramod Kumar and Browne, Martin (2011) Tissue differentiation around a short stemmed metaphyseal loading implant employing a modified mechanoregulatory algorithm: a finite element study. Journal of Orthopaedic Research, 29 (5), 787-794. (doi:10.1002/jor.21305). (PMID:21437960)

Record type: Article

Abstract

Short stemmed cementless implants are being used increasingly to avoid problems associated with their long stemmed counterparts such as size, stiffness, and bulky nature, which can contribute to stress shielding, fractures, and hence loosening. They are also thought to enhance physiological loading of the femur. We performed a computational investigation of the possible tissue differentiation and bone ingrowth processes for a specific type of stemless implant using a mechanoregulatory hypothesis, with modifications to simulate tissue differentiation, and simplified loading conditions. The peak forces during stair climbing and normal walking were investigated to evaluate their influence on the process. The results were compared to clinical studies for relevance and corroboration. The majority of the tissue type formed was fibrous, occupying the proximal regions of the implant. The lateral flare design feature of the implant was predicted to enhance bone and cartilage formation in regions beneath it compared to the same design without a flare. The percentage of bone formed increased through the iterations and accounted for nearly 35% of the tissue at the end of the iterations in Gruen zones 2 and 6, replacing cartilage tissue as differentiation progressed. This agreed well with clinical data showing similar regions of bone formation and suggests that the distal regions of the implant under the lateral flare, resting in the metaphyseal region of the bone, promoted implant stability.

This record has no associated files available for download.

More information

e-pub ahead of print date: 17 December 2010
Published date: May 2011
Organisations: Bioengineering Group

Identifiers

Local EPrints ID: 337386
URI: http://eprints.soton.ac.uk/id/eprint/337386
ISSN: 0736-0266
PURE UUID: 03af4bb0-9288-46e9-b2fe-ca7f7736a783
ORCID for Martin Browne: ORCID iD orcid.org/0000-0001-5184-050X

Catalogue record

Date deposited: 25 Apr 2012 11:12
Last modified: 15 Mar 2024 02:50

Export record

Altmetrics

Contributors

Author: Pramod Kumar Puthumanapully
Author: Martin Browne ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×