The University of Southampton
University of Southampton Institutional Repository

Screen-printed potentiometric sensors for chloride measurement in soils

Screen-printed potentiometric sensors for chloride measurement in soils
Screen-printed potentiometric sensors for chloride measurement in soils
Screen-printed potentiometric sensors have been developed to detect the presence of chloride ions within moist soils. In work previously published by some of the authors, sensor lifetimes in excess of 1 year have been established with near Nernstian response to chloride ions (-49.8 ± 1.7 mV per decade) over the range 0.1 mM (3.55 mg/L) to 200 mM (7.09 g/L). The sensors demonstrate the ability to measure transient changes in soil chloride concentration allowing chloride retention times in different types of soil to be determined
1157-1160
Cranny, Andy
2ebc2ccb-7d3e-4a6a-91ac-9f089741939e
Harris, N.R.
237cfdbd-86e4-4025-869c-c85136f14dfd
White, N.M.
c7be4c26-e419-4e5c-9420-09fc02e2ac9c
Barrett-Lennard, E.
81bd9bcb-0ac7-44f0-938f-696232b09d52
Coles, N.
e79edc82-0374-46ee-95be-1c58703ad44d
Rivers, M.
e427f6ea-815d-4f64-90ca-7319e8e218f3
Smettem, K.
3adb806a-4e1a-4140-9dcb-4f11ee1006eb
Wu, J.
5a0119e5-a760-4ff5-90b9-ec69926ce501
Cranny, Andy
2ebc2ccb-7d3e-4a6a-91ac-9f089741939e
Harris, N.R.
237cfdbd-86e4-4025-869c-c85136f14dfd
White, N.M.
c7be4c26-e419-4e5c-9420-09fc02e2ac9c
Barrett-Lennard, E.
81bd9bcb-0ac7-44f0-938f-696232b09d52
Coles, N.
e79edc82-0374-46ee-95be-1c58703ad44d
Rivers, M.
e427f6ea-815d-4f64-90ca-7319e8e218f3
Smettem, K.
3adb806a-4e1a-4140-9dcb-4f11ee1006eb
Wu, J.
5a0119e5-a760-4ff5-90b9-ec69926ce501

Cranny, Andy, Harris, N.R., White, N.M., Barrett-Lennard, E., Coles, N., Rivers, M., Smettem, K. and Wu, J. (2012) Screen-printed potentiometric sensors for chloride measurement in soils. Procedia Engineering, 47, 1157-1160. (doi:10.1016/j.proeng.2012.09.357).

Record type: Article

Abstract

Screen-printed potentiometric sensors have been developed to detect the presence of chloride ions within moist soils. In work previously published by some of the authors, sensor lifetimes in excess of 1 year have been established with near Nernstian response to chloride ions (-49.8 ± 1.7 mV per decade) over the range 0.1 mM (3.55 mg/L) to 200 mM (7.09 g/L). The sensors demonstrate the ability to measure transient changes in soil chloride concentration allowing chloride retention times in different types of soil to be determined

Text
Eurosensors2012_Cranny.pdf - Version of Record
Restricted to Repository staff only
Request a copy

More information

e-pub ahead of print date: September 2012
Additional Information: Proceedings of Eurosensors XXVI, September 9-12, 2012, Kraków, Poland
Venue - Dates: Eurosensors XXVI, 2012-09-01
Organisations: EEE

Identifiers

Local EPrints ID: 344321
URI: http://eprints.soton.ac.uk/id/eprint/344321
PURE UUID: 416e1e36-ae70-4dbb-8906-7fb861bc4d5f
ORCID for N.R. Harris: ORCID iD orcid.org/0000-0003-4122-2219
ORCID for N.M. White: ORCID iD orcid.org/0000-0003-1532-6452

Catalogue record

Date deposited: 18 Oct 2012 07:44
Last modified: 15 Mar 2024 02:46

Export record

Altmetrics

Contributors

Author: Andy Cranny
Author: N.R. Harris ORCID iD
Author: N.M. White ORCID iD
Author: E. Barrett-Lennard
Author: N. Coles
Author: M. Rivers
Author: K. Smettem
Author: J. Wu

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×