Screen-printed potentiometric sensors for chloride
measurement in soils
Screen-printed potentiometric sensors for chloride
measurement in soils
Screen-printed potentiometric sensors have been developed to detect the presence of chloride ions within moist soils. In work previously published by some of the authors, sensor lifetimes in excess of 1 year have been established with near Nernstian response to chloride ions (-49.8 ± 1.7 mV per decade) over the range 0.1 mM (3.55 mg/L) to 200 mM (7.09 g/L). The sensors demonstrate the ability to measure transient changes in soil chloride concentration allowing chloride retention times in different types of soil to be determined
1157-1160
Cranny, Andy
2ebc2ccb-7d3e-4a6a-91ac-9f089741939e
Harris, N.R.
237cfdbd-86e4-4025-869c-c85136f14dfd
White, N.M.
c7be4c26-e419-4e5c-9420-09fc02e2ac9c
Barrett-Lennard, E.
81bd9bcb-0ac7-44f0-938f-696232b09d52
Coles, N.
e79edc82-0374-46ee-95be-1c58703ad44d
Rivers, M.
e427f6ea-815d-4f64-90ca-7319e8e218f3
Smettem, K.
3adb806a-4e1a-4140-9dcb-4f11ee1006eb
Wu, J.
5a0119e5-a760-4ff5-90b9-ec69926ce501
Cranny, Andy
2ebc2ccb-7d3e-4a6a-91ac-9f089741939e
Harris, N.R.
237cfdbd-86e4-4025-869c-c85136f14dfd
White, N.M.
c7be4c26-e419-4e5c-9420-09fc02e2ac9c
Barrett-Lennard, E.
81bd9bcb-0ac7-44f0-938f-696232b09d52
Coles, N.
e79edc82-0374-46ee-95be-1c58703ad44d
Rivers, M.
e427f6ea-815d-4f64-90ca-7319e8e218f3
Smettem, K.
3adb806a-4e1a-4140-9dcb-4f11ee1006eb
Wu, J.
5a0119e5-a760-4ff5-90b9-ec69926ce501
Cranny, Andy, Harris, N.R., White, N.M., Barrett-Lennard, E., Coles, N., Rivers, M., Smettem, K. and Wu, J.
(2012)
Screen-printed potentiometric sensors for chloride
measurement in soils.
Procedia Engineering, 47, .
(doi:10.1016/j.proeng.2012.09.357).
Abstract
Screen-printed potentiometric sensors have been developed to detect the presence of chloride ions within moist soils. In work previously published by some of the authors, sensor lifetimes in excess of 1 year have been established with near Nernstian response to chloride ions (-49.8 ± 1.7 mV per decade) over the range 0.1 mM (3.55 mg/L) to 200 mM (7.09 g/L). The sensors demonstrate the ability to measure transient changes in soil chloride concentration allowing chloride retention times in different types of soil to be determined
Text
Eurosensors2012_Cranny.pdf
- Version of Record
Restricted to Repository staff only
Request a copy
More information
e-pub ahead of print date: September 2012
Additional Information:
Proceedings of Eurosensors XXVI, September 9-12, 2012, Kraków, Poland
Venue - Dates:
Eurosensors XXVI, 2012-09-01
Organisations:
EEE
Identifiers
Local EPrints ID: 344321
URI: http://eprints.soton.ac.uk/id/eprint/344321
PURE UUID: 416e1e36-ae70-4dbb-8906-7fb861bc4d5f
Catalogue record
Date deposited: 18 Oct 2012 07:44
Last modified: 15 Mar 2024 02:46
Export record
Altmetrics
Contributors
Author:
Andy Cranny
Author:
N.R. Harris
Author:
N.M. White
Author:
E. Barrett-Lennard
Author:
N. Coles
Author:
M. Rivers
Author:
K. Smettem
Author:
J. Wu
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics