Determination of muscle loading at the hip joint for use in pre-clinical testing

Determination of muscle loading at the hip joint for use in pre-clinical testing
Determination of muscle loading at the hip joint for use in pre-clinical testing
The stability of joint endoprostheses depends on the loading conditions to which the implant-bone complex is exposed. Due to a lack of appropriate muscle force data, less complex loading conditions tend to be considered in vitro. The goal of this study was to develop a load profile that better simulates the in vivo loading conditions of a "typical" total hip replacement patient and considers the interdependence of muscle and joint forces. The development of the load profile was based on a computer model of the lower extremities that has been validated against in vivo data. This model was simplified by grouping functionally similar hip muscles. Muscle and joint contact forces were computed for an average data set of up to four patients throughout walking and stair climbing. The calculated hip contact forces were compared to the average of the in vivo measured forces. The final derived load profile included the forces of up to four muscles at the instances of maximum in vivo hip joint loading during both walking and stair climbing. The hip contact forces differed by less than 10% from the peak in vivo value for a "typical" patient. The derived load profile presented here is the first that is based on validated musculoskeletal analyses and seems achievable in an in vitro test set-up. It should therefore form the basis for further standardisation of pre-clinical testing by providing a more realistic approximation of physiological loading conditions.
hip joint, loading, joint contact, muscle forces, simulation, pre-clinical testing
0021-9290
1155-1163
Heller, M.O.
3da19d2a-f34d-4ff1-8a34-9b5a7e695829
Bergmann, G.
0e5e06cd-2009-449f-a27c-4bcae0968a2f
Kassi, J.P.
41777fbb-4817-4753-ae88-1ee1b8d94b31
Claes, L.
0d49608f-bb00-4db4-8ad1-458bf9f59550
Haas, N.P.
2eb6acab-3bde-4c16-8e57-6be990ad420f
Duda, G.N.
32d09622-34ad-49dd-8314-3f61c99a764e
Heller, M.O.
3da19d2a-f34d-4ff1-8a34-9b5a7e695829
Bergmann, G.
0e5e06cd-2009-449f-a27c-4bcae0968a2f
Kassi, J.P.
41777fbb-4817-4753-ae88-1ee1b8d94b31
Claes, L.
0d49608f-bb00-4db4-8ad1-458bf9f59550
Haas, N.P.
2eb6acab-3bde-4c16-8e57-6be990ad420f
Duda, G.N.
32d09622-34ad-49dd-8314-3f61c99a764e

Heller, M.O., Bergmann, G., Kassi, J.P., Claes, L., Haas, N.P. and Duda, G.N. (2005) Determination of muscle loading at the hip joint for use in pre-clinical testing. Journal of Biomechanics, 38 (5), 1155-1163. (doi:10.1016/j.jbiomech.2004.05.022).

Record type: Article

Abstract

The stability of joint endoprostheses depends on the loading conditions to which the implant-bone complex is exposed. Due to a lack of appropriate muscle force data, less complex loading conditions tend to be considered in vitro. The goal of this study was to develop a load profile that better simulates the in vivo loading conditions of a "typical" total hip replacement patient and considers the interdependence of muscle and joint forces. The development of the load profile was based on a computer model of the lower extremities that has been validated against in vivo data. This model was simplified by grouping functionally similar hip muscles. Muscle and joint contact forces were computed for an average data set of up to four patients throughout walking and stair climbing. The calculated hip contact forces were compared to the average of the in vivo measured forces. The final derived load profile included the forces of up to four muscles at the instances of maximum in vivo hip joint loading during both walking and stair climbing. The hip contact forces differed by less than 10% from the peak in vivo value for a "typical" patient. The derived load profile presented here is the first that is based on validated musculoskeletal analyses and seems achievable in an in vitro test set-up. It should therefore form the basis for further standardisation of pre-clinical testing by providing a more realistic approximation of physiological loading conditions.

This record has no associated files available for download.

More information

Published date: May 2005
Keywords: hip joint, loading, joint contact, muscle forces, simulation, pre-clinical testing
Organisations: Bioengineering Group

Identifiers

Local EPrints ID: 348504
URI: http://eprints.soton.ac.uk/id/eprint/348504
ISSN: 0021-9290
PURE UUID: 84758ad0-45f6-4f8e-8f81-37ed3bfdadac
ORCID for M.O. Heller: ORCID iD orcid.org/0000-0002-7879-1135

Catalogue record

Date deposited: 26 Feb 2013 12:02
Last modified: 15 Mar 2024 03:43

Export record

Altmetrics

Contributors

Author: M.O. Heller ORCID iD
Author: G. Bergmann
Author: J.P. Kassi
Author: L. Claes
Author: N.P. Haas
Author: G.N. Duda

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×