Studies of the cavitational effects of clinical ultrasound by sonoluminescence: 2. Thresholds for sonoluminescence from a therapeutic ultrasound beam and the effect of temperature and duty cycle
Studies of the cavitational effects of clinical ultrasound by sonoluminescence: 2. Thresholds for sonoluminescence from a therapeutic ultrasound beam and the effect of temperature and duty cycle
Sonoluminescence, produced when a therapeutic ultrasound generator operating at 1 MHz was used to insonate a tank of water, was detected using a photomultiplier tube and analysed using pulse height analysis. Spectra of the number of counts per second were obtained for the complete range of observed pulse heights, under exposure conditions similar to those used in clinical practice. Water containing different concentrations of dissolved gases and an agar solution were investigated during the course of the experiments. Measurements were made to establish a threshold for sonoluminescence and the total sonoluminescent light output from tap water insonated with continuous wave ultrasound at 1 W cm-2 was estimated. The density of free radicals produced under these conditions was also estimated. The effects of temperature and duty cycle were investigated.
Sonoluminescence increased with temperature over the range 22-45 ºC and pulsed regimens produced more sonoluminescence than continuous wave ultrasound over a significant part of the pulse height spectrum.
1249-1260
Pickworth, M.J.W.
8a0e0f89-fb53-4538-abb8-507923eeaf08
Dendy, P.P.
ee1144be-8597-4abb-b01d-54470a991ba1
Leighton, T.G.
3e5262ce-1d7d-42eb-b013-fcc5c286bbae
Walton, A.J.
2ac47979-cc42-4acd-9828-ead8a7897e85
1988
Pickworth, M.J.W.
8a0e0f89-fb53-4538-abb8-507923eeaf08
Dendy, P.P.
ee1144be-8597-4abb-b01d-54470a991ba1
Leighton, T.G.
3e5262ce-1d7d-42eb-b013-fcc5c286bbae
Walton, A.J.
2ac47979-cc42-4acd-9828-ead8a7897e85
Pickworth, M.J.W., Dendy, P.P., Leighton, T.G. and Walton, A.J.
(1988)
Studies of the cavitational effects of clinical ultrasound by sonoluminescence: 2. Thresholds for sonoluminescence from a therapeutic ultrasound beam and the effect of temperature and duty cycle.
Physics in Medicine and Biology, 33 (11), .
(doi:10.1088/0031-9155/33/11/003).
Abstract
Sonoluminescence, produced when a therapeutic ultrasound generator operating at 1 MHz was used to insonate a tank of water, was detected using a photomultiplier tube and analysed using pulse height analysis. Spectra of the number of counts per second were obtained for the complete range of observed pulse heights, under exposure conditions similar to those used in clinical practice. Water containing different concentrations of dissolved gases and an agar solution were investigated during the course of the experiments. Measurements were made to establish a threshold for sonoluminescence and the total sonoluminescent light output from tap water insonated with continuous wave ultrasound at 1 W cm-2 was estimated. The density of free radicals produced under these conditions was also estimated. The effects of temperature and duty cycle were investigated.
Sonoluminescence increased with temperature over the range 22-45 ºC and pulsed regimens produced more sonoluminescence than continuous wave ultrasound over a significant part of the pulse height spectrum.
Text
# 1988 Pickworth Part 2 (PMB) Pub2493.pdf
- Version of Record
Restricted to Repository staff only
Request a copy
More information
Published date: 1988
Organisations:
Acoustics Group
Identifiers
Local EPrints ID: 349439
URI: http://eprints.soton.ac.uk/id/eprint/349439
PURE UUID: a3d73cfe-b035-416a-9340-f082d9d18a62
Catalogue record
Date deposited: 05 Mar 2013 14:10
Last modified: 15 Mar 2024 02:45
Export record
Altmetrics
Contributors
Author:
M.J.W. Pickworth
Author:
P.P. Dendy
Author:
A.J. Walton
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics