The effect on performance of fabrication parameter variations of thick-film screen printed silver/silver chloride potentiometric reference electrodes
The effect on performance of fabrication parameter variations of thick-film screen printed silver/silver chloride potentiometric reference electrodes
Thick-film screen printed silver-silver chloride (Ag/AgCl) reference electrodes have been fabricated and investigated as an alternative to liquid electrolyte Ag/AgCl reference electrodes. The performance of the electrodes was examined with variations of the potassium chloride (KCl) concentration in the final (top) layer of the electrode. Also, different types of binder (glass and polymer) were tested for the underlying Ag/AgCl layer. The addition of another layer on top of the KCl containing salt matrix layer has been found to provide a better stability in varying concentrations of KCl test solutions. The electrodes were found to give a satisfactory performance when tested for stability in different pH solutions.
1-8
Sophocleous, Marios
908541f4-d6e1-4fdf-9423-fddc2b12bcbf
Glanc, Monika
751cad93-88be-462b-92e8-c7b2bd876e62
Atkinson, John
5e9729b2-0e1f-400d-a889-c74f6390ea58
Garcia-Breijo, Eduardo
53771f80-0c8e-439f-8f23-87f1742e9486
1 August 2013
Sophocleous, Marios
908541f4-d6e1-4fdf-9423-fddc2b12bcbf
Glanc, Monika
751cad93-88be-462b-92e8-c7b2bd876e62
Atkinson, John
5e9729b2-0e1f-400d-a889-c74f6390ea58
Garcia-Breijo, Eduardo
53771f80-0c8e-439f-8f23-87f1742e9486
Sophocleous, Marios, Glanc, Monika, Atkinson, John and Garcia-Breijo, Eduardo
(2013)
The effect on performance of fabrication parameter variations of thick-film screen printed silver/silver chloride potentiometric reference electrodes.
Sensors and Actuators A: Physical, 197, .
(doi:10.1016/j.sna.2013.03.036).
Abstract
Thick-film screen printed silver-silver chloride (Ag/AgCl) reference electrodes have been fabricated and investigated as an alternative to liquid electrolyte Ag/AgCl reference electrodes. The performance of the electrodes was examined with variations of the potassium chloride (KCl) concentration in the final (top) layer of the electrode. Also, different types of binder (glass and polymer) were tested for the underlying Ag/AgCl layer. The addition of another layer on top of the KCl containing salt matrix layer has been found to provide a better stability in varying concentrations of KCl test solutions. The electrodes were found to give a satisfactory performance when tested for stability in different pH solutions.
Text
The Effect on Performance of Fabrication Parameter Variations.pdf
- Author's Original
More information
Published date: 1 August 2013
Organisations:
Mechatronics
Identifiers
Local EPrints ID: 350790
URI: http://eprints.soton.ac.uk/id/eprint/350790
ISSN: 0924-4247
PURE UUID: 460b0b2a-da64-4d03-822f-58370e018170
Catalogue record
Date deposited: 08 Apr 2013 12:46
Last modified: 15 Mar 2024 02:33
Export record
Altmetrics
Contributors
Author:
Marios Sophocleous
Author:
Monika Glanc
Author:
Eduardo Garcia-Breijo
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics