ECG compression for remote healthcare systems using selective thresholding based on energy compaction

ECG compression for remote healthcare systems using selective thresholding based on energy compaction
ECG compression for remote healthcare systems using selective thresholding based on energy compaction
This paper presents a wavelet-based low-complexity Electrocardiogram (ECG) compression algorithm for mobile healthcare systems, in the backdrop of real clinical requirements. The proposed method aims at achieving good trade-off between the compression ratio (CR) and the fidelity of the reconstructed signal, to preserve the clinically diagnostic features. Keeping the computational complexity at a minimal level is paramount since the application area we consider is that of remote cardio- vascular monitoring, where continuous sensing and processing takes place in low-power, computationally constrained devices. The proposed compression methodology is based on the Discrete Wavelet Transform (DWT). The energy packing efficiency of the DWT coefficients at different resolution levels is analysed and a thresholding policy is applied to select only those coefficients which have significant contribution to the original signal total energy. The proposed methodology is evaluated on normal and abnormal ECG signals extracted from the MIT-BIH database and achieves an average compression ratio of 16.5:1, an average percent root mean square difference of 0.75 and an average cross correlation value of 0.98.
Biswas, D.
76983b74-d729-4aae-94c3-94d05e9b2ed4
Mazomenos, E.B.
23983827-c7e7-4ee1-bfc8-986aa3594279
Maharatna, K.
93bef0a2-e011-4622-8c56-5447da4cd5dd
Biswas, D.
76983b74-d729-4aae-94c3-94d05e9b2ed4
Mazomenos, E.B.
23983827-c7e7-4ee1-bfc8-986aa3594279
Maharatna, K.
93bef0a2-e011-4622-8c56-5447da4cd5dd

Biswas, D., Mazomenos, E.B. and Maharatna, K. (2012) ECG compression for remote healthcare systems using selective thresholding based on energy compaction. 2012 International Symposium on Signals, Systems, and Electronics (ISSSE), Potsdam, Germany. 03 - 05 Oct 2012.

Record type: Conference or Workshop Item (Paper)

Abstract

This paper presents a wavelet-based low-complexity Electrocardiogram (ECG) compression algorithm for mobile healthcare systems, in the backdrop of real clinical requirements. The proposed method aims at achieving good trade-off between the compression ratio (CR) and the fidelity of the reconstructed signal, to preserve the clinically diagnostic features. Keeping the computational complexity at a minimal level is paramount since the application area we consider is that of remote cardio- vascular monitoring, where continuous sensing and processing takes place in low-power, computationally constrained devices. The proposed compression methodology is based on the Discrete Wavelet Transform (DWT). The energy packing efficiency of the DWT coefficients at different resolution levels is analysed and a thresholding policy is applied to select only those coefficients which have significant contribution to the original signal total energy. The proposed methodology is evaluated on normal and abnormal ECG signals extracted from the MIT-BIH database and achieves an average compression ratio of 16.5:1, an average percent root mean square difference of 0.75 and an average cross correlation value of 0.98.

Text
issse2012.pdf - Accepted Manuscript
Download (368kB)

More information

Published date: 5 October 2012
Venue - Dates: 2012 International Symposium on Signals, Systems, and Electronics (ISSSE), Potsdam, Germany, 2012-10-03 - 2012-10-05
Organisations: Electronics & Computer Science

Identifiers

Local EPrints ID: 353069
URI: http://eprints.soton.ac.uk/id/eprint/353069
PURE UUID: f642c37d-78b7-442a-82ce-ea6ddba24e95

Catalogue record

Date deposited: 03 Jun 2013 08:17
Last modified: 14 Mar 2024 14:00

Export record

Contributors

Author: D. Biswas
Author: E.B. Mazomenos
Author: K. Maharatna

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×