The University of Southampton
University of Southampton Institutional Repository

Energy-Efficient and High-Speed Robust System Design for Remote Cardiac Health Monitoring

Energy-Efficient and High-Speed Robust System Design for Remote Cardiac Health Monitoring
Energy-Efficient and High-Speed Robust System Design for Remote Cardiac Health Monitoring
In this paper we propose an energy-efficient and high-speed robust system design methodology targeting remote cardiac health monitoring. The proposed system comprises of two main modules-low-complexity 3D CORDIC based FastICA followed by the adaptive permutation ambiguity solver to solve the permutation indeterminacy encountered in Independent Component Analysis (ICA) for artifacts removal from recorded 3-channel ECG signals within the remote health monitoring environment for cardiovascular patients. Since FastICA is computationally intensive, its direct architectural mapping from the algorithm may not result in an optimum architecture suitable for the resource constrained applications including remote healthcare. Therefore our proposed 3D CORDIC based FastICA system architecture would reduce the hardware complexity significantly. Unlike the existing approaches to solver permutation ambiguity, the proposed methodology takes into account the non-stationarity of the ECG signal thereby making this methodology more realistic. Since the proposed methodology is based on the adaptive template matching scheme, once the channel containing the intended ECG signal is detected, there is no need to continue this proposed methodology for the rest of the channels. Thus it saves computation time as well as minimizes the overall energy consumption of the system. The proposed methodology is tested using 275 ECG signal recordings of patients obtained from clinically well-known MIT-BIH PTB databases and real-life ECG data collected from University of Southampton hospital corrupted by an exhaustive set of 5 bodily artifacts and noise. The proposed methodology is found to save on the 55.55% of the otherwise incurred energy and 33.33% speed improvement as compared to the existing approaches.
978-3-642-32111-5
519-530
Acharyya, Amit
f7c95a87-04ac-4d13-a74c-0c4d89b1c79c
Agarwal, Abhinav
9c33e0fc-cf1b-41ce-bd48-9b299f8cbfeb
Singh, Abhijeet
a9ff4c4a-c2cd-4e54-9ced-c4a4325d7ca8
Shafik, R.A.
aa0bdafc-b022-4cb2-a8ef-4bf8a03ba524
Ahamed, Shaikh Rafi
563f784c-102d-4a6b-9ea0-e9034874973e
Acharyya, Amit
f7c95a87-04ac-4d13-a74c-0c4d89b1c79c
Agarwal, Abhinav
9c33e0fc-cf1b-41ce-bd48-9b299f8cbfeb
Singh, Abhijeet
a9ff4c4a-c2cd-4e54-9ced-c4a4325d7ca8
Shafik, R.A.
aa0bdafc-b022-4cb2-a8ef-4bf8a03ba524
Ahamed, Shaikh Rafi
563f784c-102d-4a6b-9ea0-e9034874973e

Acharyya, Amit, Agarwal, Abhinav, Singh, Abhijeet, Shafik, R.A. and Ahamed, Shaikh Rafi (2014) Energy-Efficient and High-Speed Robust System Design for Remote Cardiac Health Monitoring. Journal of Low Power Electronics, 10 (3), 519-530.

Record type: Article

Abstract

In this paper we propose an energy-efficient and high-speed robust system design methodology targeting remote cardiac health monitoring. The proposed system comprises of two main modules-low-complexity 3D CORDIC based FastICA followed by the adaptive permutation ambiguity solver to solve the permutation indeterminacy encountered in Independent Component Analysis (ICA) for artifacts removal from recorded 3-channel ECG signals within the remote health monitoring environment for cardiovascular patients. Since FastICA is computationally intensive, its direct architectural mapping from the algorithm may not result in an optimum architecture suitable for the resource constrained applications including remote healthcare. Therefore our proposed 3D CORDIC based FastICA system architecture would reduce the hardware complexity significantly. Unlike the existing approaches to solver permutation ambiguity, the proposed methodology takes into account the non-stationarity of the ECG signal thereby making this methodology more realistic. Since the proposed methodology is based on the adaptive template matching scheme, once the channel containing the intended ECG signal is detected, there is no need to continue this proposed methodology for the rest of the channels. Thus it saves computation time as well as minimizes the overall energy consumption of the system. The proposed methodology is tested using 275 ECG signal recordings of patients obtained from clinically well-known MIT-BIH PTB databases and real-life ECG data collected from University of Southampton hospital corrupted by an exhaustive set of 5 bodily artifacts and noise. The proposed methodology is found to save on the 55.55% of the otherwise incurred energy and 33.33% speed improvement as compared to the existing approaches.

This record has no associated files available for download.

More information

Published date: 2014
Organisations: Electronics & Computer Science

Identifiers

Local EPrints ID: 353379
URI: http://eprints.soton.ac.uk/id/eprint/353379
ISBN: 978-3-642-32111-5
PURE UUID: 1d45eebc-810c-404f-b58c-258f81607cae

Catalogue record

Date deposited: 05 Jun 2013 14:00
Last modified: 22 Jul 2022 18:33

Export record

Contributors

Author: Amit Acharyya
Author: Abhinav Agarwal
Author: Abhijeet Singh
Author: R.A. Shafik
Author: Shaikh Rafi Ahamed

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×