The University of Southampton
University of Southampton Institutional Repository

Reliability testing of vasti activity measurements in taped and untaped patellofemoral conditions during single leg squatting in healthy subjects: A pilot study

Reliability testing of vasti activity measurements in taped and untaped patellofemoral conditions during single leg squatting in healthy subjects: A pilot study
Reliability testing of vasti activity measurements in taped and untaped patellofemoral conditions during single leg squatting in healthy subjects: A pilot study
INTRODUCTION: Measuring vasti muscles activity may provide reliable evidence for patellar taping to correct probable malalignment in subjects with patellofemoral pain syndrome (PFPS). The aim of present study was to examine the reliability of vasti activity measurements in different patellofemoral conditions during squatting in healthy subjects.

METHODS: Using an electromyography (EMG) unit, the ratio amplitudes and onsets of VMO and VL muscles of twelve healthy subjects were assessed during single leg squatting. Data was collected from surface electrodes placed over the muscle bellies of the VMO and VL. This procedure was performed on the right knees, before (BT), during (WT) and shortly after patellar taping (SAT).

RESULTS: While the CV (coefficient of variation), ICC (intra class correlation coefficient), LSD (least significant difference) and SEM (standard error of measurement) values revealed the high reliability of the VMO/VL amplitude measurements during single leg squatting (p < 0.05), the related values demonstrated poor to moderate reliability of VMO-VL onset measurements during the similar activity (p > 0.05).

CONCLUSION: Reliability tests conducted during the current study showed that, while the relative amplitude of vasti could be used as highly reliable parameter, the muscle onsets of vasti had poor to moderate reliability.
vasti reliability test, single leg squatting, taped and untaped patellofemoral joint
1360-8592
271-277
Mostamand, J.
520b832a-942b-48a8-a176-fd445c3551eb
Bader, D.L.
9884d4f6-2607-4d48-bf0c-62bdcc0d1dbf
Hudson, Z.
79ac72b9-c513-430a-aba1-0c05cc6ba47d
Mostamand, J.
520b832a-942b-48a8-a176-fd445c3551eb
Bader, D.L.
9884d4f6-2607-4d48-bf0c-62bdcc0d1dbf
Hudson, Z.
79ac72b9-c513-430a-aba1-0c05cc6ba47d

Mostamand, J., Bader, D.L. and Hudson, Z. (2013) Reliability testing of vasti activity measurements in taped and untaped patellofemoral conditions during single leg squatting in healthy subjects: A pilot study. Journal of Bodywork and Movement Therapies, 17 (3), 271-277. (doi:10.1016/j.jbmt.2012.08.005). (PMID:23768269)

Record type: Article

Abstract

INTRODUCTION: Measuring vasti muscles activity may provide reliable evidence for patellar taping to correct probable malalignment in subjects with patellofemoral pain syndrome (PFPS). The aim of present study was to examine the reliability of vasti activity measurements in different patellofemoral conditions during squatting in healthy subjects.

METHODS: Using an electromyography (EMG) unit, the ratio amplitudes and onsets of VMO and VL muscles of twelve healthy subjects were assessed during single leg squatting. Data was collected from surface electrodes placed over the muscle bellies of the VMO and VL. This procedure was performed on the right knees, before (BT), during (WT) and shortly after patellar taping (SAT).

RESULTS: While the CV (coefficient of variation), ICC (intra class correlation coefficient), LSD (least significant difference) and SEM (standard error of measurement) values revealed the high reliability of the VMO/VL amplitude measurements during single leg squatting (p < 0.05), the related values demonstrated poor to moderate reliability of VMO-VL onset measurements during the similar activity (p > 0.05).

CONCLUSION: Reliability tests conducted during the current study showed that, while the relative amplitude of vasti could be used as highly reliable parameter, the muscle onsets of vasti had poor to moderate reliability.

This record has no associated files available for download.

More information

Published date: July 2013
Keywords: vasti reliability test, single leg squatting, taped and untaped patellofemoral joint
Organisations: Faculty of Health Sciences

Identifiers

Local EPrints ID: 354905
URI: http://eprints.soton.ac.uk/id/eprint/354905
ISSN: 1360-8592
PURE UUID: f093e4d9-642e-4be3-bbc3-cfbe72a0c80e
ORCID for D.L. Bader: ORCID iD orcid.org/0000-0002-1208-3507

Catalogue record

Date deposited: 29 Jul 2013 15:38
Last modified: 14 Mar 2024 14:25

Export record

Altmetrics

Contributors

Author: J. Mostamand
Author: D.L. Bader ORCID iD
Author: Z. Hudson

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×