The vibration discomfort of standing persons: 0.5–16-Hz fore-and-aft, lateral, and vertical vibration
The vibration discomfort of standing persons: 0.5–16-Hz fore-and-aft, lateral, and vertical vibration
To minimise the discomfort of standing people caused by vibration of a floor, it is necessary to know how their sensitivity to vibration depends on the frequency of the vibration. This study was designed to determine how the discomfort of standing people exposed to horizontal and vertical vibration depends on vibration frequency over the range 0.5–16 Hz. Using the method of magnitude estimation, sixteen subjects judged the discomfort caused by fore-and-aft, lateral, and vertical sinusoidal vibration at each of the sixteen preferred one-third octave centre frequencies from 0.5 to 16 Hz at each of nine magnitudes. Subjects also reported the main cause of their discomfort. Equivalent comfort contours were constructed, reflecting the effect of frequency on subject sensitivity to vibration acceleration. With horizontal vibration, at frequencies between 0.5 and 3.15 Hz the discomfort was similar when the vibration velocity was similar, whereas at frequencies between 3.15 and 16 Hz the discomfort was similar when the vibration acceleration was similar. At frequencies less than 3.15 Hz, the subjects experienced problems with their stability, whereas at higher frequencies vibration discomfort was mostly experienced from sensations in the legs and feet. With vertical vibration, discomfort was felt in the lower-body and upper-body at all frequencies. The frequency weightings in current standards for predicting the vibration discomfort of standing persons have been greatly influenced by the findings of studies with seated subjects: the weightings are consistent with the experimentally determined frequency-dependence of discomfort caused by vertical vibration but inconsistent with the experimentally determined frequency-dependence of discomfort caused by horizontal vibration. The results suggest that the responses of seated and standing people are similar for vertical vibration, but differ for horizontal vibration, partly due to greater instability in standing persons.
816-826
Thuong, O.
7beb3981-70b5-4a3c-bc6e-5083d8158e68
Griffin, M.J.
24112494-9774-40cb-91b7-5b4afe3c41b8
February 2011
Thuong, O.
7beb3981-70b5-4a3c-bc6e-5083d8158e68
Griffin, M.J.
24112494-9774-40cb-91b7-5b4afe3c41b8
Thuong, O. and Griffin, M.J.
(2011)
The vibration discomfort of standing persons: 0.5–16-Hz fore-and-aft, lateral, and vertical vibration.
Journal of Sound and Vibration, 330 (4), .
(doi:10.1016/j.jsv.2010.08.040).
Abstract
To minimise the discomfort of standing people caused by vibration of a floor, it is necessary to know how their sensitivity to vibration depends on the frequency of the vibration. This study was designed to determine how the discomfort of standing people exposed to horizontal and vertical vibration depends on vibration frequency over the range 0.5–16 Hz. Using the method of magnitude estimation, sixteen subjects judged the discomfort caused by fore-and-aft, lateral, and vertical sinusoidal vibration at each of the sixteen preferred one-third octave centre frequencies from 0.5 to 16 Hz at each of nine magnitudes. Subjects also reported the main cause of their discomfort. Equivalent comfort contours were constructed, reflecting the effect of frequency on subject sensitivity to vibration acceleration. With horizontal vibration, at frequencies between 0.5 and 3.15 Hz the discomfort was similar when the vibration velocity was similar, whereas at frequencies between 3.15 and 16 Hz the discomfort was similar when the vibration acceleration was similar. At frequencies less than 3.15 Hz, the subjects experienced problems with their stability, whereas at higher frequencies vibration discomfort was mostly experienced from sensations in the legs and feet. With vertical vibration, discomfort was felt in the lower-body and upper-body at all frequencies. The frequency weightings in current standards for predicting the vibration discomfort of standing persons have been greatly influenced by the findings of studies with seated subjects: the weightings are consistent with the experimentally determined frequency-dependence of discomfort caused by vertical vibration but inconsistent with the experimentally determined frequency-dependence of discomfort caused by horizontal vibration. The results suggest that the responses of seated and standing people are similar for vertical vibration, but differ for horizontal vibration, partly due to greater instability in standing persons.
Text
14677 OT-MJG 2011 Frequency-dependence_discomfort_standing
- Accepted Manuscript
More information
Published date: February 2011
Organisations:
Human Sciences Group
Identifiers
Local EPrints ID: 354925
URI: http://eprints.soton.ac.uk/id/eprint/354925
ISSN: 0022-460X
PURE UUID: c5a4f92b-57ac-4b81-8172-6b9281055131
Catalogue record
Date deposited: 23 Jul 2013 09:39
Last modified: 14 Mar 2024 14:26
Export record
Altmetrics
Contributors
Author:
O. Thuong
Author:
M.J. Griffin
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics