The University of Southampton
University of Southampton Institutional Repository

Difference thresholds for vibration of the foot: dependence on frequency and magnitude of vibration

Difference thresholds for vibration of the foot: dependence on frequency and magnitude of vibration
Difference thresholds for vibration of the foot: dependence on frequency and magnitude of vibration
The smallest change in vibration intensity for the change to be perceptible (i.e. intensity difference threshold) has not previously been reported for vibration of the foot. This study investigated the influence of vibration magnitude and vibration frequency on intensity difference thresholds for the perception of vertical sinusoidal vibration of the foot. It was hypothesised that relative intensity difference thresholds (i.e. Weber fractions) for 16-Hz vibration mediated by the non-Pacinian I (NPI) channel would differ from relative intensity difference thresholds for 125-Hz vibration mediated by the Pacinian (P) channel. Absolute thresholds, difference thresholds, and the locations of vibration sensation caused by vertical vibration of the right foot were determined for 12 subjects using the up-down-transformed-response method together with the three-down-one-up rule. The difference thresholds and locations of sensation were obtained at six reference magnitudes (at 6, 9, 12, 18, 24, 30 dB above absolute threshold—i.e. sensation levels, SL). For 16-Hz vibration, the median relative difference thresholds were not significantly dependent on vibration magnitude and were in the range 0.19 (at 30 dB SL) to 0.27 (at 9 dB SL). For 125-Hz vibration, the median relative difference thresholds varied between 0.17 (at 9 dB SL) and 0.34 (at 30 dB SL), with difference thresholds from 6 to 12 dB SL significantly less than those from 18 to 30 dB SL. At vibration magnitudes slightly in excess of absolute thresholds (i.e. 6–12 dB SL) there were no significant differences between Weber fractions obtained from the P channel (at 125 Hz) and the NPI channel (at 16 Hz). At 24 and 30 dB SL, the 125-Hz Weber fractions were significantly greater than the 16-Hz Weber fractions. Differences in the 125-Hz Weber fractions may have been caused by a reduction in the discriminability of the P channel at high levels of excitation, resulting in one or more NP channel mediating the difference thresholds at magnitudes greater than 18 dB SL. At high magnitudes, a change of channel mediating the Weber fractions may have been responsible for different Weber fractions with 16- and 125-Hz vibration.

0022-460X
805-815
Forta, N
b5880395-94c5-4d30-ab63-1d17f95b3866
Griffin, M.J.
24112494-9774-40cb-91b7-5b4afe3c41b8
Morioka, M.
8eb26aca-8773-4e45-8737-61c2438d30d9
Forta, N
b5880395-94c5-4d30-ab63-1d17f95b3866
Griffin, M.J.
24112494-9774-40cb-91b7-5b4afe3c41b8
Morioka, M.
8eb26aca-8773-4e45-8737-61c2438d30d9

Forta, N, Griffin, M.J. and Morioka, M. (2011) Difference thresholds for vibration of the foot: dependence on frequency and magnitude of vibration. Journal of Sound and Vibration, 330 (4), 805-815. (doi:10.1016/j.jsv.2010.08.039).

Record type: Article

Abstract

The smallest change in vibration intensity for the change to be perceptible (i.e. intensity difference threshold) has not previously been reported for vibration of the foot. This study investigated the influence of vibration magnitude and vibration frequency on intensity difference thresholds for the perception of vertical sinusoidal vibration of the foot. It was hypothesised that relative intensity difference thresholds (i.e. Weber fractions) for 16-Hz vibration mediated by the non-Pacinian I (NPI) channel would differ from relative intensity difference thresholds for 125-Hz vibration mediated by the Pacinian (P) channel. Absolute thresholds, difference thresholds, and the locations of vibration sensation caused by vertical vibration of the right foot were determined for 12 subjects using the up-down-transformed-response method together with the three-down-one-up rule. The difference thresholds and locations of sensation were obtained at six reference magnitudes (at 6, 9, 12, 18, 24, 30 dB above absolute threshold—i.e. sensation levels, SL). For 16-Hz vibration, the median relative difference thresholds were not significantly dependent on vibration magnitude and were in the range 0.19 (at 30 dB SL) to 0.27 (at 9 dB SL). For 125-Hz vibration, the median relative difference thresholds varied between 0.17 (at 9 dB SL) and 0.34 (at 30 dB SL), with difference thresholds from 6 to 12 dB SL significantly less than those from 18 to 30 dB SL. At vibration magnitudes slightly in excess of absolute thresholds (i.e. 6–12 dB SL) there were no significant differences between Weber fractions obtained from the P channel (at 125 Hz) and the NPI channel (at 16 Hz). At 24 and 30 dB SL, the 125-Hz Weber fractions were significantly greater than the 16-Hz Weber fractions. Differences in the 125-Hz Weber fractions may have been caused by a reduction in the discriminability of the P channel at high levels of excitation, resulting in one or more NP channel mediating the difference thresholds at magnitudes greater than 18 dB SL. At high magnitudes, a change of channel mediating the Weber fractions may have been responsible for different Weber fractions with 16- and 125-Hz vibration.

This record has no associated files available for download.

More information

Published date: 14 February 2011
Organisations: Human Sciences Group

Identifiers

Local EPrints ID: 354928
URI: http://eprints.soton.ac.uk/id/eprint/354928
ISSN: 0022-460X
PURE UUID: 1d15e60f-ffe4-49fd-8e23-b86575a1d589
ORCID for M.J. Griffin: ORCID iD orcid.org/0000-0003-0743-9502

Catalogue record

Date deposited: 23 Jul 2013 10:15
Last modified: 14 Mar 2024 14:26

Export record

Altmetrics

Contributors

Author: N Forta
Author: M.J. Griffin ORCID iD
Author: M. Morioka

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×