Difference thresholds for vibration of the foot: dependence on frequency and magnitude of vibration
Difference thresholds for vibration of the foot: dependence on frequency and magnitude of vibration
The smallest change in vibration intensity for the change to be perceptible (i.e. intensity difference threshold) has not previously been reported for vibration of the foot. This study investigated the influence of vibration magnitude and vibration frequency on intensity difference thresholds for the perception of vertical sinusoidal vibration of the foot. It was hypothesised that relative intensity difference thresholds (i.e. Weber fractions) for 16-Hz vibration mediated by the non-Pacinian I (NPI) channel would differ from relative intensity difference thresholds for 125-Hz vibration mediated by the Pacinian (P) channel. Absolute thresholds, difference thresholds, and the locations of vibration sensation caused by vertical vibration of the right foot were determined for 12 subjects using the up-down-transformed-response method together with the three-down-one-up rule. The difference thresholds and locations of sensation were obtained at six reference magnitudes (at 6, 9, 12, 18, 24, 30 dB above absolute threshold—i.e. sensation levels, SL). For 16-Hz vibration, the median relative difference thresholds were not significantly dependent on vibration magnitude and were in the range 0.19 (at 30 dB SL) to 0.27 (at 9 dB SL). For 125-Hz vibration, the median relative difference thresholds varied between 0.17 (at 9 dB SL) and 0.34 (at 30 dB SL), with difference thresholds from 6 to 12 dB SL significantly less than those from 18 to 30 dB SL. At vibration magnitudes slightly in excess of absolute thresholds (i.e. 6–12 dB SL) there were no significant differences between Weber fractions obtained from the P channel (at 125 Hz) and the NPI channel (at 16 Hz). At 24 and 30 dB SL, the 125-Hz Weber fractions were significantly greater than the 16-Hz Weber fractions. Differences in the 125-Hz Weber fractions may have been caused by a reduction in the discriminability of the P channel at high levels of excitation, resulting in one or more NP channel mediating the difference thresholds at magnitudes greater than 18 dB SL. At high magnitudes, a change of channel mediating the Weber fractions may have been responsible for different Weber fractions with 16- and 125-Hz vibration.
805-815
Forta, N
b5880395-94c5-4d30-ab63-1d17f95b3866
Griffin, M.J.
24112494-9774-40cb-91b7-5b4afe3c41b8
Morioka, M.
8eb26aca-8773-4e45-8737-61c2438d30d9
14 February 2011
Forta, N
b5880395-94c5-4d30-ab63-1d17f95b3866
Griffin, M.J.
24112494-9774-40cb-91b7-5b4afe3c41b8
Morioka, M.
8eb26aca-8773-4e45-8737-61c2438d30d9
Forta, N, Griffin, M.J. and Morioka, M.
(2011)
Difference thresholds for vibration of the foot: dependence on frequency and magnitude of vibration.
Journal of Sound and Vibration, 330 (4), .
(doi:10.1016/j.jsv.2010.08.039).
Abstract
The smallest change in vibration intensity for the change to be perceptible (i.e. intensity difference threshold) has not previously been reported for vibration of the foot. This study investigated the influence of vibration magnitude and vibration frequency on intensity difference thresholds for the perception of vertical sinusoidal vibration of the foot. It was hypothesised that relative intensity difference thresholds (i.e. Weber fractions) for 16-Hz vibration mediated by the non-Pacinian I (NPI) channel would differ from relative intensity difference thresholds for 125-Hz vibration mediated by the Pacinian (P) channel. Absolute thresholds, difference thresholds, and the locations of vibration sensation caused by vertical vibration of the right foot were determined for 12 subjects using the up-down-transformed-response method together with the three-down-one-up rule. The difference thresholds and locations of sensation were obtained at six reference magnitudes (at 6, 9, 12, 18, 24, 30 dB above absolute threshold—i.e. sensation levels, SL). For 16-Hz vibration, the median relative difference thresholds were not significantly dependent on vibration magnitude and were in the range 0.19 (at 30 dB SL) to 0.27 (at 9 dB SL). For 125-Hz vibration, the median relative difference thresholds varied between 0.17 (at 9 dB SL) and 0.34 (at 30 dB SL), with difference thresholds from 6 to 12 dB SL significantly less than those from 18 to 30 dB SL. At vibration magnitudes slightly in excess of absolute thresholds (i.e. 6–12 dB SL) there were no significant differences between Weber fractions obtained from the P channel (at 125 Hz) and the NPI channel (at 16 Hz). At 24 and 30 dB SL, the 125-Hz Weber fractions were significantly greater than the 16-Hz Weber fractions. Differences in the 125-Hz Weber fractions may have been caused by a reduction in the discriminability of the P channel at high levels of excitation, resulting in one or more NP channel mediating the difference thresholds at magnitudes greater than 18 dB SL. At high magnitudes, a change of channel mediating the Weber fractions may have been responsible for different Weber fractions with 16- and 125-Hz vibration.
This record has no associated files available for download.
More information
Published date: 14 February 2011
Organisations:
Human Sciences Group
Identifiers
Local EPrints ID: 354928
URI: http://eprints.soton.ac.uk/id/eprint/354928
ISSN: 0022-460X
PURE UUID: 1d15e60f-ffe4-49fd-8e23-b86575a1d589
Catalogue record
Date deposited: 23 Jul 2013 10:15
Last modified: 14 Mar 2024 14:26
Export record
Altmetrics
Contributors
Author:
N Forta
Author:
M.J. Griffin
Author:
M. Morioka
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.