104 MHz rate single-shot recording with subpicosecond resolution using temporal imaging
104 MHz rate single-shot recording with subpicosecond resolution using temporal imaging
We demonstrate temporal imaging for the measurement and characterization of optical arbitrary waveforms and events. The system measures single-shot 200 ps frames at a rate of 104 MHz, where each frame is time magnified by a factor of -42.4x. Impulse response tests show that the system enables 783 fs resolution when placed at the front end of a 20 GHz oscilloscope. Modulated pulse trains characterize the system’s impulse response, jitter, and frame-to-frame variation.
196-203
Hernandez, Vincent J.
94e3000c-62b1-4f5e-a218-ccdd83894036
Bennett, Corey V.
2ded1ee5-5deb-4b1a-a075-5a4beafca678
Moran, Bryan D.
9fdb74fe-cc7b-42c4-99aa-0885b3be687a
Drobshoff, Alexander D.
d86239d7-d5f8-4111-b775-920f07485c53
Chang, Derek
c5c8d915-d188-4da4-ada6-970169ccb6ec
Langrock, Carsten
8c335f5b-f058-42ec-bc51-9eb8daf3ffb1
Fejer, Martin M.
935735b1-0046-4009-ac16-df618bac3049
Ibsen, Morten
22e58138-5ce9-4bed-87e1-735c91f8f3b9
14 January 2013
Hernandez, Vincent J.
94e3000c-62b1-4f5e-a218-ccdd83894036
Bennett, Corey V.
2ded1ee5-5deb-4b1a-a075-5a4beafca678
Moran, Bryan D.
9fdb74fe-cc7b-42c4-99aa-0885b3be687a
Drobshoff, Alexander D.
d86239d7-d5f8-4111-b775-920f07485c53
Chang, Derek
c5c8d915-d188-4da4-ada6-970169ccb6ec
Langrock, Carsten
8c335f5b-f058-42ec-bc51-9eb8daf3ffb1
Fejer, Martin M.
935735b1-0046-4009-ac16-df618bac3049
Ibsen, Morten
22e58138-5ce9-4bed-87e1-735c91f8f3b9
Hernandez, Vincent J., Bennett, Corey V., Moran, Bryan D., Drobshoff, Alexander D., Chang, Derek, Langrock, Carsten, Fejer, Martin M. and Ibsen, Morten
(2013)
104 MHz rate single-shot recording with subpicosecond resolution using temporal imaging.
Optics Express, 21 (1), .
(doi:10.1364/OE.21.000196).
Abstract
We demonstrate temporal imaging for the measurement and characterization of optical arbitrary waveforms and events. The system measures single-shot 200 ps frames at a rate of 104 MHz, where each frame is time magnified by a factor of -42.4x. Impulse response tests show that the system enables 783 fs resolution when placed at the front end of a 20 GHz oscilloscope. Modulated pulse trains characterize the system’s impulse response, jitter, and frame-to-frame variation.
Text
oe-21-1-196
- Version of Record
More information
Published date: 14 January 2013
Organisations:
Optoelectronics Research Centre
Identifiers
Local EPrints ID: 356370
URI: http://eprints.soton.ac.uk/id/eprint/356370
ISSN: 1094-4087
PURE UUID: f670a8c6-c445-417d-8554-d1de25beb50c
Catalogue record
Date deposited: 13 Sep 2013 10:13
Last modified: 14 Mar 2024 14:47
Export record
Altmetrics
Contributors
Author:
Vincent J. Hernandez
Author:
Corey V. Bennett
Author:
Bryan D. Moran
Author:
Alexander D. Drobshoff
Author:
Derek Chang
Author:
Carsten Langrock
Author:
Martin M. Fejer
Author:
Morten Ibsen
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics