Determination of rare earth elements in sixteen silicate reference samples by ICP-MS after Tm addition and ion-exchange separation
Determination of rare earth elements in sixteen silicate reference samples by ICP-MS after Tm addition and ion-exchange separation
This study reports the results of thirteen rare earth elements (REE) in sixteen geochemical reference samples. The analytical procedure involved dissolution of a whole rock or mineral separate, spiking with Tm, and separation of the REE using a simple ion-exchange chromatography procedure. The resulting REE solutions were analysed by ICP-MS. The results are compared with literature values. The agreement between our data and recommended or ID-TIMS values is very favorable. The precision of the technique is better than 5% (2) for all the REE.
133-139
Barrat, J.A.
acfa951b-8140-4574-bb54-9b30f9d75113
Keller, F.
a6bd7ee0-2f6b-4f7a-b13e-62aa902164c5
Amosse, J.
9e3dd6cb-21fb-4370-84d7-a465168fcb6e
Taylor, R.N.
094be7fd-ef61-4acd-a795-7daba2bc6183
Nesbitt, R.W.
6a124ad1-4e6d-4407-b92f-592f7fd682e4
Hirata, T.
06bf4c97-4d71-4017-a148-c9aea2ed62e1
April 1996
Barrat, J.A.
acfa951b-8140-4574-bb54-9b30f9d75113
Keller, F.
a6bd7ee0-2f6b-4f7a-b13e-62aa902164c5
Amosse, J.
9e3dd6cb-21fb-4370-84d7-a465168fcb6e
Taylor, R.N.
094be7fd-ef61-4acd-a795-7daba2bc6183
Nesbitt, R.W.
6a124ad1-4e6d-4407-b92f-592f7fd682e4
Hirata, T.
06bf4c97-4d71-4017-a148-c9aea2ed62e1
Barrat, J.A., Keller, F., Amosse, J., Taylor, R.N., Nesbitt, R.W. and Hirata, T.
(1996)
Determination of rare earth elements in sixteen silicate reference samples by ICP-MS after Tm addition and ion-exchange separation.
Geostandards and Geoanalytical Research, 20 (1), .
(doi:10.1111/j.1751-908X.1996.tb00177.x).
Abstract
This study reports the results of thirteen rare earth elements (REE) in sixteen geochemical reference samples. The analytical procedure involved dissolution of a whole rock or mineral separate, spiking with Tm, and separation of the REE using a simple ion-exchange chromatography procedure. The resulting REE solutions were analysed by ICP-MS. The results are compared with literature values. The agreement between our data and recommended or ID-TIMS values is very favorable. The precision of the technique is better than 5% (2) for all the REE.
This record has no associated files available for download.
More information
Published date: April 1996
Organisations:
Geochemistry
Identifiers
Local EPrints ID: 361643
URI: http://eprints.soton.ac.uk/id/eprint/361643
ISSN: 0150-5505
PURE UUID: 2ce765dd-976d-466a-95f3-f2f995c924dd
Catalogue record
Date deposited: 28 Jan 2014 13:52
Last modified: 15 Mar 2024 02:50
Export record
Altmetrics
Contributors
Author:
J.A. Barrat
Author:
F. Keller
Author:
J. Amosse
Author:
R.W. Nesbitt
Author:
T. Hirata
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics