Processing of commercial purity titanium by ECAP using a 90 degrees die at room temperature
Processing of commercial purity titanium by ECAP using a 90 degrees die at room temperature
Experiments were conducted to determine whether it is feasible to process commercial purity (CP) titanium (grade 1) by equal-channel angular pressing (ECAP) at room temperature with a die having an internal angle of 90°. Billets were successfully processed through up to 4 passes using a pressing speed of 3.5 mm s?1. These results appear to represent the first successful processing of CP-Ti at room temperature using a 90° die. Processing by ECAP through 4 passes reduced the grain size from an initial value of ~25 µm in the unprocessed condition to an equiaxed grain size of ~150 nm. The results show that the hardness and tensile strength are increased significantly after ECAP and the material exhibits excellent elongations up to ~45%–48% in tensile testing at room temperature. The success in processing CP-Ti at room temperature with a 90° die provides opportunities for incorporating additional processing steps in order to gain further grain refinement and strength enhancement
482-489
Zhao, Xicheng
d17c4b44-27af-4384-9f37-b501509b0b26
Yang, Xirong
dfc64746-740d-401f-aad0-5189250434b4
Liu, Xiaoyan
86c14145-8101-4e1d-9d30-40baac2c5bee
Wang, Chuan Ting
80ad9adf-a9df-49ed-934d-fa64505b920d
Huang, Yi
9f4df815-51c1-4ee8-ad63-a92bf997103e
Langdon, Terence G.
86e69b4f-e16d-4830-bf8a-5a9c11f0de86
2014
Zhao, Xicheng
d17c4b44-27af-4384-9f37-b501509b0b26
Yang, Xirong
dfc64746-740d-401f-aad0-5189250434b4
Liu, Xiaoyan
86c14145-8101-4e1d-9d30-40baac2c5bee
Wang, Chuan Ting
80ad9adf-a9df-49ed-934d-fa64505b920d
Huang, Yi
9f4df815-51c1-4ee8-ad63-a92bf997103e
Langdon, Terence G.
86e69b4f-e16d-4830-bf8a-5a9c11f0de86
Zhao, Xicheng, Yang, Xirong, Liu, Xiaoyan, Wang, Chuan Ting, Huang, Yi and Langdon, Terence G.
(2014)
Processing of commercial purity titanium by ECAP using a 90 degrees die at room temperature.
Materials Science and Engineering: A, 607, .
(doi:10.1016/j.msea.2014.04.014).
Abstract
Experiments were conducted to determine whether it is feasible to process commercial purity (CP) titanium (grade 1) by equal-channel angular pressing (ECAP) at room temperature with a die having an internal angle of 90°. Billets were successfully processed through up to 4 passes using a pressing speed of 3.5 mm s?1. These results appear to represent the first successful processing of CP-Ti at room temperature using a 90° die. Processing by ECAP through 4 passes reduced the grain size from an initial value of ~25 µm in the unprocessed condition to an equiaxed grain size of ~150 nm. The results show that the hardness and tensile strength are increased significantly after ECAP and the material exhibits excellent elongations up to ~45%–48% in tensile testing at room temperature. The success in processing CP-Ti at room temperature with a 90° die provides opportunities for incorporating additional processing steps in order to gain further grain refinement and strength enhancement
This record has no associated files available for download.
More information
Published date: 2014
Organisations:
Engineering Mats & Surface Engineerg Gp
Identifiers
Local EPrints ID: 363785
URI: http://eprints.soton.ac.uk/id/eprint/363785
ISSN: 0921-5093
PURE UUID: 3f1632e0-9665-4bd4-99aa-d92db1b82cc3
Catalogue record
Date deposited: 14 Apr 2014 08:53
Last modified: 15 Mar 2024 03:39
Export record
Altmetrics
Contributors
Author:
Xicheng Zhao
Author:
Xirong Yang
Author:
Xiaoyan Liu
Author:
Chuan Ting Wang
Author:
Yi Huang
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics