Microtaper fiber excitation effects in bottle microresonators
Microtaper fiber excitation effects in bottle microresonators
We have carried out a systematic study of the effect of microtaper diameter on the spectral characteristics of bottle microresonators. By increasing the microtaper-diameter (Dt) from 2µm to 10µm results in progressively cleaner spectra. The transmission depth at resonance varies from ~15dB (@Dt = 2µm) to >3dB (@Dt = 10µm). The loaded Q factors were measured to be >10+6 in all cases. However, with microtaper Dt = 10µm clearly-resolved single resonance peaks could be observed and free-spectral ranges could be easily identified. At some transmission resonances, we have observed LP01 to LP11 mode transformation at the excitation microtaper waist, for the first time, as the resonance is scanned.
Mohd Nasir, M.N.
f44744b8-8eb9-4051-b871-0eabda932d37
Ding, Ming
12b31750-03c4-4f76-aab6-64feb8f13bf0
Murugan, G.S.
a867686e-0535-46cc-ad85-c2342086b25b
Zervas, M.N.
1840a474-dd50-4a55-ab74-6f086aa3f701
Mohd Nasir, M.N.
f44744b8-8eb9-4051-b871-0eabda932d37
Ding, Ming
12b31750-03c4-4f76-aab6-64feb8f13bf0
Murugan, G.S.
a867686e-0535-46cc-ad85-c2342086b25b
Zervas, M.N.
1840a474-dd50-4a55-ab74-6f086aa3f701
Mohd Nasir, M.N., Ding, Ming, Murugan, G.S. and Zervas, M.N.
(2013)
Microtaper fiber excitation effects in bottle microresonators.
SPIE Photonics West 2013, , San Francisco, United States.
02 - 07 Feb 2013.
(doi:10.1117/12.2004282).
Record type:
Conference or Workshop Item
(Paper)
Abstract
We have carried out a systematic study of the effect of microtaper diameter on the spectral characteristics of bottle microresonators. By increasing the microtaper-diameter (Dt) from 2µm to 10µm results in progressively cleaner spectra. The transmission depth at resonance varies from ~15dB (@Dt = 2µm) to >3dB (@Dt = 10µm). The loaded Q factors were measured to be >10+6 in all cases. However, with microtaper Dt = 10µm clearly-resolved single resonance peaks could be observed and free-spectral ranges could be easily identified. At some transmission resonances, we have observed LP01 to LP11 mode transformation at the excitation microtaper waist, for the first time, as the resonance is scanned.
More information
e-pub ahead of print date: 2013
Venue - Dates:
SPIE Photonics West 2013, , San Francisco, United States, 2013-02-02 - 2013-02-07
Organisations:
Optoelectronics Research Centre
Identifiers
Local EPrints ID: 365585
URI: http://eprints.soton.ac.uk/id/eprint/365585
PURE UUID: cc574f6f-21dd-4be1-bfe8-c4014b033c34
Catalogue record
Date deposited: 10 Jun 2014 14:21
Last modified: 15 Mar 2024 03:23
Export record
Altmetrics
Contributors
Author:
M.N. Mohd Nasir
Author:
Ming Ding
Author:
G.S. Murugan
Author:
M.N. Zervas
Download statistics
Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.
View more statistics