The University of Southampton
University of Southampton Institutional Repository

Resolution improvement of a ratiometric wavelength measurement system by using an optical microfibre coupler

Resolution improvement of a ratiometric wavelength measurement system by using an optical microfibre coupler
Resolution improvement of a ratiometric wavelength measurement system by using an optical microfibre coupler
The application of microfibre couplers in a comb-filter-based ratiometric wavelength measurement system is discussed. The fabrication of microfibre coupler is presented and its temperature-dependent performance is investigated. The resolution of the ratiometric wavelength measurement system with a microfiber coupler is significantly improved in comparison with a conventional ratiometric system to better than 4 pm maintaining the potential for high measurement speed and wide measurable wavelength range.
Wang, Pengfei
a1ba240f-d4f0-4150-bcd8-cb418e841dcb
Ding, M.
12b31750-03c4-4f76-aab6-64feb8f13bf0
Brambilla, G.
815d9712-62c7-47d1-8860-9451a363a6c8
Semenova, Y.
45267263-f4a6-47bd-b84d-768e9b0d2dfc
Wu, G.
4cea1c70-6af2-45b9-9d71-2b85a1e9a81f
Farrell, G.
09f74789-4377-4964-a6da-793184ad8c13
Wang, Pengfei
a1ba240f-d4f0-4150-bcd8-cb418e841dcb
Ding, M.
12b31750-03c4-4f76-aab6-64feb8f13bf0
Brambilla, G.
815d9712-62c7-47d1-8860-9451a363a6c8
Semenova, Y.
45267263-f4a6-47bd-b84d-768e9b0d2dfc
Wu, G.
4cea1c70-6af2-45b9-9d71-2b85a1e9a81f
Farrell, G.
09f74789-4377-4964-a6da-793184ad8c13

Wang, Pengfei, Ding, M., Brambilla, G., Semenova, Y., Wu, G. and Farrell, G. (2012) Resolution improvement of a ratiometric wavelength measurement system by using an optical microfibre coupler. SOPO '12, Shanghai Shi, China. 20 - 23 May 2012.

Record type: Conference or Workshop Item (Paper)

Abstract

The application of microfibre couplers in a comb-filter-based ratiometric wavelength measurement system is discussed. The fabrication of microfibre coupler is presented and its temperature-dependent performance is investigated. The resolution of the ratiometric wavelength measurement system with a microfiber coupler is significantly improved in comparison with a conventional ratiometric system to better than 4 pm maintaining the potential for high measurement speed and wide measurable wavelength range.

Text
5518.pdf - Other
Download (361kB)

More information

e-pub ahead of print date: May 2012
Venue - Dates: SOPO '12, Shanghai Shi, China, 2012-05-20 - 2012-05-23
Organisations: Optoelectronics Research Centre

Identifiers

Local EPrints ID: 368439
URI: http://eprints.soton.ac.uk/id/eprint/368439
PURE UUID: 17c46792-3544-4ce1-af45-8b881ae21225
ORCID for G. Brambilla: ORCID iD orcid.org/0000-0002-5730-0499

Catalogue record

Date deposited: 18 Sep 2014 13:03
Last modified: 15 Mar 2024 03:10

Export record

Contributors

Author: Pengfei Wang
Author: M. Ding
Author: G. Brambilla ORCID iD
Author: Y. Semenova
Author: G. Wu
Author: G. Farrell

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×