The University of Southampton
University of Southampton Institutional Repository

Sampled-current voltammetry at microdisk electrodes: kinetic information from pseudo steady state voltammograms

Sampled-current voltammetry at microdisk electrodes: kinetic information from pseudo steady state voltammograms
Sampled-current voltammetry at microdisk electrodes: kinetic information from pseudo steady state voltammograms
In sampled-current voltammetry (SCV), current transients acquired after stepping the potential along the redox wave of interest are sampled at a fixed time to produce a sigmoidal current–potential curve akin to a pseudo steady state voltammogram. Repeating the sampling for different times yields a family of sampled-current voltammograms, one for each time scale. The concept has been used to describe the current–time-potential relationship at planar electrodes but rarely employed as an electroanalytical method except in normal pulse voltammetry where the chronoamperograms are sampled once to produce a single voltammogram. Here we combine the unique properties of microdisk electrodes with SCV and report a simple protocol to analyze and compare the microdisk sampled-current voltammograms irrespective of sampling time. This is particularly useful for microelectrodes where cyclic voltammograms change shape as the mass transport regime evolves from planar diffusion at short times to hemispherical diffusion at long times. We also combine microdisk sampled-current voltammetry (MSCV) with a conditioning waveform to produce voltammograms where each data point is recorded with the same electrode history and demonstrate that the waveform is crucial to obtaining reliable sampled-current voltammograms below 100 ms. To facilitate qualitative analysis of the voltammograms, we convert the current–potential data recorded at different time scales into a unique sigmoidal curve, which clearly highlights kinetic complications. To quantitatively model the MSCVs, we derive an analytical expression which accounts for the diffusion regime and kinetic parameters. The procedure is validated with the reduction of Ru(NH3)63+, a model one electron outer sphere process, and applied to the derivation of the kinetic parameters for the reduction of Fe3+ on Pt microdisks. The methodology reported here is easily implemented on computer controlled electrochemical workstations as a new electroanalytical method to exploit the unique properties of microelectrodes, in particular at short times.
0003-2700
9917-9923
Perry, Samuel C.
1120f856-6cbf-4bb6-9573-792c99afc443
Al Shandoudi, Laila M.
db24a599-92f6-4f6c-b52a-ef6019bf007e
Denuault, Guy
5c76e69f-e04e-4be5-83c5-e729887ffd4e
Perry, Samuel C.
1120f856-6cbf-4bb6-9573-792c99afc443
Al Shandoudi, Laila M.
db24a599-92f6-4f6c-b52a-ef6019bf007e
Denuault, Guy
5c76e69f-e04e-4be5-83c5-e729887ffd4e

Perry, Samuel C., Al Shandoudi, Laila M. and Denuault, Guy (2014) Sampled-current voltammetry at microdisk electrodes: kinetic information from pseudo steady state voltammograms. Analytical Chemistry, 86 (19), 9917-9923. (doi:10.1021/ac502645e).

Record type: Article

Abstract

In sampled-current voltammetry (SCV), current transients acquired after stepping the potential along the redox wave of interest are sampled at a fixed time to produce a sigmoidal current–potential curve akin to a pseudo steady state voltammogram. Repeating the sampling for different times yields a family of sampled-current voltammograms, one for each time scale. The concept has been used to describe the current–time-potential relationship at planar electrodes but rarely employed as an electroanalytical method except in normal pulse voltammetry where the chronoamperograms are sampled once to produce a single voltammogram. Here we combine the unique properties of microdisk electrodes with SCV and report a simple protocol to analyze and compare the microdisk sampled-current voltammograms irrespective of sampling time. This is particularly useful for microelectrodes where cyclic voltammograms change shape as the mass transport regime evolves from planar diffusion at short times to hemispherical diffusion at long times. We also combine microdisk sampled-current voltammetry (MSCV) with a conditioning waveform to produce voltammograms where each data point is recorded with the same electrode history and demonstrate that the waveform is crucial to obtaining reliable sampled-current voltammograms below 100 ms. To facilitate qualitative analysis of the voltammograms, we convert the current–potential data recorded at different time scales into a unique sigmoidal curve, which clearly highlights kinetic complications. To quantitatively model the MSCVs, we derive an analytical expression which accounts for the diffusion regime and kinetic parameters. The procedure is validated with the reduction of Ru(NH3)63+, a model one electron outer sphere process, and applied to the derivation of the kinetic parameters for the reduction of Fe3+ on Pt microdisks. The methodology reported here is easily implemented on computer controlled electrochemical workstations as a new electroanalytical method to exploit the unique properties of microelectrodes, in particular at short times.

Text
20140826_Perry_et_al_revised_as_submitted.pdf - Accepted Manuscript
Download (889kB)

More information

Published date: September 2014
Organisations: Electrochemistry

Identifiers

Local EPrints ID: 371607
URI: http://eprints.soton.ac.uk/id/eprint/371607
ISSN: 0003-2700
PURE UUID: 4ae8a3d1-2acd-40aa-a7bd-c6a28ccf610f
ORCID for Guy Denuault: ORCID iD orcid.org/0000-0002-8630-9492

Catalogue record

Date deposited: 10 Nov 2014 14:18
Last modified: 15 Mar 2024 02:44

Export record

Altmetrics

Contributors

Author: Samuel C. Perry
Author: Laila M. Al Shandoudi
Author: Guy Denuault ORCID iD

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×