The University of Southampton
University of Southampton Institutional Repository

Optimizing frequency-to-electrode allocation for individual cochlear implant users

Optimizing frequency-to-electrode allocation for individual cochlear implant users
Optimizing frequency-to-electrode allocation for individual cochlear implant users
Individual adjustment of frequency-to-electrode assignment in cochlear implants (CIs) may potentially improve speech perception outcomes. Twelve adult CI users were recruited for an experiment, in which frequency maps were adjusted using insertion angles estimated from post-operative x rays; results were analyzed for ten participants with good quality x rays. The allocations were a mapping to the Greenwood function, a compressed map limited to the area containing spiral ganglion (SG) cells, a reduced frequency range map (RFR), and participants' clinical maps. A trial period of at least six weeks was given for the clinical, Greenwood, and SG maps although participants could return to their clinical map if they wished. Performance with the Greenwood map was poor for both sentence and vowel perception and correlated with insertion angle; performance with the SG map was poorer than for the clinical map. The RFR map was significantly better than the clinical map for three participants, for sentence perception, but worse for three others. Those with improved performance had relatively deep insertions and poor electrode discrimination ability for apical electrodes. The results suggest that CI performance could be improved by adjustment of the frequency allocation, based on a measure of insertion angle and/or electrode discrimination ability
0001-4966
3313-3326
Grasmeder, M.L.
206e6b44-d1cd-43f5-99ac-588ab02d44ef
Verschuur, C.A.
5e15ee1c-3a44-4dbe-ad43-ec3b50111e41
Batty, Vincent B.
c64eeef6-e54b-4f36-8ac9-2ab23b17ecc4
Grasmeder, M.L.
206e6b44-d1cd-43f5-99ac-588ab02d44ef
Verschuur, C.A.
5e15ee1c-3a44-4dbe-ad43-ec3b50111e41
Batty, Vincent B.
c64eeef6-e54b-4f36-8ac9-2ab23b17ecc4

Grasmeder, M.L., Verschuur, C.A. and Batty, Vincent B. (2014) Optimizing frequency-to-electrode allocation for individual cochlear implant users. Journal of the Acoustical Society of America, 136 (6), 3313-3326. (doi:10.1121/1.4900831). (PMID:25480076)

Record type: Article

Abstract

Individual adjustment of frequency-to-electrode assignment in cochlear implants (CIs) may potentially improve speech perception outcomes. Twelve adult CI users were recruited for an experiment, in which frequency maps were adjusted using insertion angles estimated from post-operative x rays; results were analyzed for ten participants with good quality x rays. The allocations were a mapping to the Greenwood function, a compressed map limited to the area containing spiral ganglion (SG) cells, a reduced frequency range map (RFR), and participants' clinical maps. A trial period of at least six weeks was given for the clinical, Greenwood, and SG maps although participants could return to their clinical map if they wished. Performance with the Greenwood map was poor for both sentence and vowel perception and correlated with insertion angle; performance with the SG map was poorer than for the clinical map. The RFR map was significantly better than the clinical map for three participants, for sentence perception, but worse for three others. Those with improved performance had relatively deep insertions and poor electrode discrimination ability for apical electrodes. The results suggest that CI performance could be improved by adjustment of the frequency allocation, based on a measure of insertion angle and/or electrode discrimination ability

Text
JASA manuscript revision 22 September 2014 for eprints.pdf - Accepted Manuscript
Download (413kB)

More information

e-pub ahead of print date: 4 December 2014
Published date: December 2014
Organisations: Faculty of Engineering and the Environment

Identifiers

Local EPrints ID: 372933
URI: http://eprints.soton.ac.uk/id/eprint/372933
ISSN: 0001-4966
PURE UUID: b20102c2-e7fa-474c-9ea8-ddd3ef4fc0f3

Catalogue record

Date deposited: 05 Jan 2015 14:02
Last modified: 14 Mar 2024 18:46

Export record

Altmetrics

Contributors

Author: M.L. Grasmeder
Author: C.A. Verschuur
Author: Vincent B. Batty

Download statistics

Downloads from ePrints over the past year. Other digital versions may also be available to download e.g. from the publisher's website.

View more statistics

Atom RSS 1.0 RSS 2.0

Contact ePrints Soton: eprints@soton.ac.uk

ePrints Soton supports OAI 2.0 with a base URL of http://eprints.soton.ac.uk/cgi/oai2

This repository has been built using EPrints software, developed at the University of Southampton, but available to everyone to use.

We use cookies to ensure that we give you the best experience on our website. If you continue without changing your settings, we will assume that you are happy to receive cookies on the University of Southampton website.

×